COMPARISON AND EXPERIMENTAL VALIDATION OF TURBULENCE MODELS FOR AN AXIAL FLOW BLOOD PUMP

被引:10
|
作者
Wang, Shuai [1 ]
Tan, Jianping [1 ]
Yu, Zheqin [1 ]
机构
[1] Cent S Univ, Coll Mech & Elect Engn, Changsha 410083, Hunan, Peoples R China
关键词
Blood pump; CFD simulation; turbulence model; PIV experiment; flow field distribution; VENTRICULAR ASSIST DEVICES; SHEAR-STRESS; PERFORMANCE; DAMAGE; FIELD;
D O I
10.1142/S0219519419400633
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Computational fluid dynamics (CFD) has become an essential tool for designing and optimizing the structure of blood pumps. However, it is still questionable which turbulence model can better obtain the flow information for axial flow blood pump. In this study, the axial flow blood pump was used as the object, and the influence of the common turbulence models on simulation was compared. Six turbulence models (standard k-epsilon model, RNG k-epsilon model, standard k-omega model, SST k-omega model, Spalart-Allmaras model, SSG Reynolds stress model) were used to simulate the pressure difference and velocity field of the pump. In parallel, we designed a novel drive system of the axial flow blood pump, which allowed the camera to capture the internal flow field. Then we measured the flow field in the impeller region based on particle image velocimetry (PIV). Through the comparison of experiments and simulation results, the average errors of velocity field obtained by the above models are 30.97%, 19.40%, 24.25%, 15.28%, 28.51%, 23.00%, respectively. Since the SST k-omega model has the smallest error, and the streamline is consistent with the experimental results, it is recommended to use SST k-omega model for numerical analysis of the axial flow blood pump.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Induction of ventricular collapse by an axial flow blood pump
    Amin, Devin V.
    Antaki, James F.
    Litwak, Philip
    Thomas, Douglas
    Wu, Zhongjun J.
    Watach, Mary
    ASAIO Journal, 44 (05):
  • [22] Miniaturization of a Magnetically Levitated Axial Flow Blood Pump
    Cheng, Shanbao
    Olles, Mark W.
    Olsen, Don B.
    Joyce, Lyle D.
    Day, Steven W.
    ARTIFICIAL ORGANS, 2010, 34 (10) : 807 - 815
  • [23] Numerical and Experimental Investigation on Axial-flow Pump
    Zhang, DeSheng
    Shi, WeiDong
    Chen, Bin
    Guan, XingFan
    PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION (ICMS2009), VOL 7, 2009, : 76 - 83
  • [24] COMPARISON OF THREE CONTROL STRATEGIES FOR AXIAL BLOOD PUMP
    Wu, Xiao
    Zhang, Xiwen
    Hao, Pengfei
    He, Feng
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2019, 19 (06)
  • [25] PIV experimental study on the flow field characteristics of axial flow blood pump under three operating conditions
    Xiao, Zhiyong
    Tan, Jianping
    Wang, Shuai
    Yu, Zheqin
    Wu, Weiqiang
    JOURNAL OF ENGINEERING-JOE, 2019, (13): : 155 - 158
  • [26] An Experimental Study of Newtonian and Non-Newtonian Flow Dynamics in an Axial Blood Pump Model
    Hu, Qi-Hui
    Li, Jing-Yin
    Zhang, Ming-Yuan
    Zhu, Xian-Ran
    ARTIFICIAL ORGANS, 2012, 36 (04) : 429 - 433
  • [27] PIV Experimental Study of the Axial Flow Blood Pump's Internal Flow Field Under Pulsatile Condition
    Wang Shuai
    Tan Jianping
    Yu Zheqin
    Xiao Zhiyong
    Wu Weiqiang
    Cheng Lizhi
    4TH INTERNATIONAL CONFERENCE ON APPLIED MATERIALS AND MANUFACTURING TECHNOLOGY, 2018, 423
  • [28] Validation of an Axial Flow Blood Pump: Computational Fluid Dynamics Results Using Particle Image Velocimetry
    Su, Boyang
    Chua, Leok Poh
    Wang, Xikun
    ARTIFICIAL ORGANS, 2012, 36 (04) : 359 - 367
  • [29] Comparison of flow characteristics of enlarged blood pump models with different impeller design
    Chua, LP
    Yu, SCM
    Leo, HL
    Chan, WK
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1999, 26 (03) : 369 - 378
  • [30] In vitro performance of a centrifugal, a mixed flow, and an axial flow blood pump
    Medical Informatics, Miyazaki Medical College Hospital, Miyazaki, Japan
    不详
    不详
    不详
    Artif. Organs, 5 (366-370):