Impedance cardiography as a noninvasive technique for atrioventricular interval optimization in cardiac resynchronization therapy

被引:41
|
作者
Braun, MU [1 ]
Schnabel, A [1 ]
Rauwolf, T [1 ]
Schulze, M [1 ]
Strasser, RH [1 ]
机构
[1] Tech Univ Dresden, Dept Internal Med & Cardiol, Med Clin 2, D-01307 Dresden, Germany
关键词
impedance cardiography; Doppler flow echocardiography; cardiac resynchronization therapy; AV-interval optimization;
D O I
10.1007/s10840-005-2361-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Impedance cardiography (IC) and Doppler echocardiography (DE) are two noninvasive methods to evaluate hemodynamics in patients with dual-chamber pacemakers. The aim of the present study was to compare both techniques in respect to their ability of AV-interval optimization in cardiac resynchronization therapy (CRT) based on cardiac output (CO) measurements. Methods and Results: Twenty-four patients (64 +/- 8 years) with congestive heart failure (EF < 35%; NYHA III-IV) and LBBB (> 150 ms) were evaluated at baseline and 1 month after implantation of a CRT-D. The optimal AV interval was defined by IC and subsequently by transaortic flow DE as the interval corresponding to the highest CO measured at different AV intervals, varying from 60 to 200 ms (with 20 ms increments). For standardization and comparison of both techniques, a fixed atriobiventricular pacing rate of 90 beats/min was used. Absolute values of COmax were higher by IC (5.8 +/- 0.9 l/min) as compared to DE (4.6 +/- 0.9 l/min, p < 0.01). The optimal AV interval as determined by IC varied interindividually from 80-180 ms (mean: 121 +/- 18 ms). In DE, the range was also 80-180 ms with the mean optimal AV interval of 128 +/- 23 ms. Thus, there was a strong correlation for AV-interval optimization in CRT between both methods (r = 0.74; p < 0.001). Conclusion: In CRT, AV-interval optimization based on CO values determined by IC correlates closely to those measured by transaortic flow DE. Impedance cardiography as an easy and cost-effective technique for AV-interval optimization is a promising alternative for routine management of heart failure patients on a beat-to-beat analysis during CRT follow-up.
引用
收藏
页码:223 / 229
页数:7
相关论文
共 50 条
  • [41] Impedance cardiography: Equivalent noninvasive alternative to thermodilution cardiac output measurement
    Van de Water, JM
    Adkison, EK
    Carswell, E
    Vogel, RL
    Dalton, ML
    FASEB JOURNAL, 2003, 17 (04): : A387 - A387
  • [42] NONINVASIVE ASSESSMENT OF CARDIAC-OUTPUT IN CHILDREN USING IMPEDANCE CARDIOGRAPHY
    BRADEN, DS
    LEATHERBURY, L
    TREIBER, FA
    STRONG, WB
    AMERICAN HEART JOURNAL, 1990, 120 (05) : 1166 - 1172
  • [43] NONINVASIVE ASSESSMENT OF CARDIAC-OUTPUT IN CHILDREN USING IMPEDANCE CARDIOGRAPHY
    BRADEN, DS
    LEATHERBURY, L
    TREIBER, FA
    STRONG, WB
    PEDIATRIC RESEARCH, 1990, 27 (04) : A28 - A28
  • [44] Resynchronization therapy optimization by intracardiac impedance
    Bocchiardo, Mario
    Vilsendorf, Dorothee Meyer Zu
    Militello, Carmelo
    Lippert, Michael
    Czygan, Gerald
    Schauerte, Patrick
    Gaita, Fiorenzo
    Stellbrink, Christoph
    EUROPACE, 2010, 12 (11): : 1589 - 1595
  • [45] Could one-year effect of cardiac resynchronization therapy on hemodynamic parameters evaluated by impedance cardiography be predicted ?
    Orszulak, M. Michal
    Filipecki, A.
    Mizia-Stec, K.
    EUROPEAN JOURNAL OF HEART FAILURE, 2016, 18 : 373 - 373
  • [46] Iterative method for atrioventricular optimization of cardiac resynchronization therapy: is beauty only in the eye of the beholder?
    Burri, Haran
    EUROPACE, 2014, 16 (12): : 1865 - 1866
  • [47] Advances in atrioventricular and interventricular optimization of cardiac resynchronization therapy - what's the gold standard?
    Rowe, Matthew K.
    Kaye, Gerald C.
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2018, 16 (03) : 183 - 196
  • [48] Optimization of cardiac resynchronization therapy
    Bhan, Amit
    Kapetanakis, Stamatis
    Monaghan, Mark J.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (09): : 1031 - 1039
  • [49] Combination of the best pacing configuration and atrioventricular and interventricular delays optimization in cardiac resynchronization therapy
    Socie, Pierre
    Squara, Fabien
    Semichon, Marc
    Thomas, Olivier
    Khemache, Alain
    Riccini, Philippe
    Squara, Pierre
    Algalarrondo, Vincent
    Moubarak, Ghassan
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (04): : 362 - 367
  • [50] Echocardiographic Atrioventricular Delay Optimization during Exercise Improves Cardiac Function in Cardiac Resynchronization Therapy Patients
    Sun, Jing Ping
    Hung, Ming-Jui
    DeLurgio, David
    Yang, Xing Sheng
    Leon, Angel
    Merlino, John D.
    CIRCULATION, 2010, 122 (21)