NONINVASIVE ASSESSMENT OF CARDIAC-OUTPUT IN CHILDREN USING IMPEDANCE CARDIOGRAPHY

被引:49
|
作者
BRADEN, DS
LEATHERBURY, L
TREIBER, FA
STRONG, WB
机构
[1] Section of Cardiology, Medical College of Georgia, Augusta, Ga
关键词
D O I
10.1016/0002-8703(90)90132-H
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study evaluated the effect of intracardiac shungting on the accuracy of thoracic bioimpedance-derived cardiac output determinations. Twenty-six patients, ranging in age from 3 months to 17 years, underwent cardiac catheterization during which simultaneous Fick and impedance measurements of cardiac output were obtained. The subjects were divided into three groups: 10 children with no intracardiac shunts, nine children with predominant left-to-right intracardiac shunts, and seven children with predominant right-to-left intracardiac shunts. Positive correlations between impedance and Fick-derived cardiac output determinations were obtained in the non-shunt group (r = 0.84), with lower correlations in the left-to-right shunt group (r = 0.70). In the right-to-left shunt group, the impedance derived cardiac output correlated with Fick pulmonary flow (r = 0.82), but the variability was unacceptably large. Although further study is needed, impedance cardiography appears to have validity as a methodology in pediatric critical care and cardiovascular health research. © 1990.
引用
收藏
页码:1166 / 1172
页数:7
相关论文
共 50 条
  • [1] NONINVASIVE ASSESSMENT OF CARDIAC-OUTPUT IN CHILDREN USING IMPEDANCE CARDIOGRAPHY
    BRADEN, DS
    LEATHERBURY, L
    TREIBER, FA
    STRONG, WB
    PEDIATRIC RESEARCH, 1990, 27 (04) : A28 - A28
  • [2] NONINVASIVE ASSESSMENT OF CARDIAC-OUTPUT BY IMPEDANCE CARDIOGRAPHY IN THE NEWBORN CANINE
    GOTSHALL, RW
    MILES, DS
    CRITICAL CARE MEDICINE, 1989, 17 (01) : 63 - 65
  • [3] CARDIAC-OUTPUT IN EXERCISE BY IMPEDANCE CARDIOGRAPHY
    DUQUESNAY, MC
    STOUTE, GJ
    HUGHSON, RL
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1985, 17 (02): : 202 - 203
  • [4] IMPEDANCE CARDIOGRAPHY AND CARDIAC-OUTPUT IN THE ELDERLY
    WILLIAMS, BO
    CAIRD, FI
    AGE AND AGEING, 1980, 9 (01) : 47 - 52
  • [6] CARDIAC-OUTPUT IN NEONATAL-PERIOD USING IMPEDANCE CARDIOGRAPHY
    COSTELOE, K
    STOCKS, J
    GODFREY, S
    MOHAPATRA, SN
    HILL, DW
    PEDIATRIC RESEARCH, 1977, 11 (12) : 1171 - 1177
  • [7] MEASUREMENT OF CARDIAC-OUTPUT IN RAT BY IMPEDANCE CARDIOGRAPHY
    CHAPMAN, BJ
    CHEN, CF
    MUNDAY, KA
    JOURNAL OF PHYSIOLOGY-LONDON, 1977, 270 (01): : P3 - P5
  • [8] IMPEDANCE CARDIOGRAPHY IN THE MEASUREMENT OF CARDIAC-OUTPUT - STUDIES IN RABBITS
    PAPPAS, CG
    WANG, X
    CONNOLLY, RJ
    SCHWAITZBERG, SD
    JOURNAL OF SURGICAL RESEARCH, 1995, 59 (04) : 504 - 510
  • [9] IDEAL MEASUREMENT OF CARDIAC-OUTPUT - IS IMPEDANCE CARDIOGRAPHY THE ANSWER
    FRANKO, ER
    VANDEWATER, JM
    WANG, X
    VASCULAR SURGERY, 1991, 25 (07): : 550 - 558
  • [10] NONINVASIVE DETERMINATION OF CARDIAC-OUTPUT BY MEANS OF IMPEDANCE CARDIOGRAPHY - COMPARATIVE EVALUATION WITH A THERMAL DILUTION TECHNIQUE
    NECHWATAL, W
    BIER, P
    EVERSMANN, A
    KONIG, E
    BASIC RESEARCH IN CARDIOLOGY, 1976, 71 (05) : 542 - 552