NONINVASIVE ASSESSMENT OF CARDIAC-OUTPUT IN CHILDREN USING IMPEDANCE CARDIOGRAPHY

被引:49
|
作者
BRADEN, DS
LEATHERBURY, L
TREIBER, FA
STRONG, WB
机构
[1] Section of Cardiology, Medical College of Georgia, Augusta, Ga
关键词
D O I
10.1016/0002-8703(90)90132-H
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study evaluated the effect of intracardiac shungting on the accuracy of thoracic bioimpedance-derived cardiac output determinations. Twenty-six patients, ranging in age from 3 months to 17 years, underwent cardiac catheterization during which simultaneous Fick and impedance measurements of cardiac output were obtained. The subjects were divided into three groups: 10 children with no intracardiac shunts, nine children with predominant left-to-right intracardiac shunts, and seven children with predominant right-to-left intracardiac shunts. Positive correlations between impedance and Fick-derived cardiac output determinations were obtained in the non-shunt group (r = 0.84), with lower correlations in the left-to-right shunt group (r = 0.70). In the right-to-left shunt group, the impedance derived cardiac output correlated with Fick pulmonary flow (r = 0.82), but the variability was unacceptably large. Although further study is needed, impedance cardiography appears to have validity as a methodology in pediatric critical care and cardiovascular health research. © 1990.
引用
收藏
页码:1166 / 1172
页数:7
相关论文
共 50 条
  • [41] NONINVASIVE DETERMINATION OF CARDIAC-OUTPUT
    TRIEBWASSER, JH
    BURPO, RP
    CAMPBELL, JC
    REARDON, WC
    JOHNSON, RL
    GLOMQVIS.G
    AMERICAN JOURNAL OF CARDIOLOGY, 1973, 31 (01): : 162 - 162
  • [42] NONINVASIVE CARDIAC-OUTPUT MEASUREMENT
    WONG, DH
    WESTERN JOURNAL OF MEDICINE, 1990, 153 (03): : 310 - 310
  • [43] NONINVASIVE ESTIMATION OF CARDIAC-OUTPUT
    WELKOWITZ, W
    CUI, Q
    QI, Y
    KOSTIS, JB
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (11) : 1100 - 1105
  • [44] THE MEASUREMENT OF CARDIAC-OUTPUT BY IMPEDANCE CARDIOGRAPHY, AND THE USE OF A COMPUTER TO FACILITATE DATA-ANALYSIS
    CHAPMAN, BJ
    JUDD, AB
    JOURNAL OF PHYSIOLOGY-LONDON, 1993, 473 : P148 - P148
  • [45] IMPEDANCE CARDIOGRAPHY FOR EVALUATION OF SYSTOLIC-TIME INTERVALS AND CARDIAC-OUTPUT AS FUNCTION OF PRELOAD
    VANDEYK, K
    MUNCH, F
    VOIGT, E
    SEYBOLDEPTING, W
    CRITICAL CARE MEDICINE, 1981, 9 (03) : 269 - 269
  • [46] VARIABILITY IN IMPEDANCE CARDIAC-OUTPUT IN MECHANICALLY VENTILATED CHILDREN
    MICKELL, JJ
    LUCKING, SE
    CHATEN, FC
    YOUNG, ES
    PEDIATRIC RESEARCH, 1989, 25 (04) : A41 - A41
  • [47] Portable impedance cardiography system for real-time noninvasive cardiac output measurement
    Chiang, CY
    Hu, WC
    Shyu, LY
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2072 - 2073
  • [48] Determination of Cardiac Output in Pulmonary Hypertension Using Impedance Cardiography
    Dupuis, Marion
    Noel-Savina, Elise
    Prevot, Gregoire
    Tetu, Laurent
    Pillard, Fabien
    Riviere, Daniel
    Didier, Alain
    RESPIRATION, 2018, 96 (06) : 500 - 506
  • [49] Monitoring Cardiac Output Using Impedance Cardiography : A Technical Review
    Kumari, Priya Darshini
    Singh, Ksh Milan
    Lazarus, Mayaluri Zefree
    Agir, Sujeevan Kumar
    2021 IEEE INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS, SMART AND GREEN TECHNOLOGIES (ICISSGT 2021), 2021, : 68 - 71
  • [50] A COMPARISON BETWEEN CARDIAC-OUTPUT DETERMINED BY IMPEDANCE CARDIOGRAPHY AND THE REBREATHING METHOD DURING EXERCISE IN MAN
    NIIZEKI, K
    MIYAMOTO, Y
    DOI, K
    JAPANESE JOURNAL OF PHYSIOLOGY, 1989, 39 (03): : 441 - 446