NONINVASIVE ASSESSMENT OF CARDIAC-OUTPUT IN CHILDREN USING IMPEDANCE CARDIOGRAPHY

被引:49
|
作者
BRADEN, DS
LEATHERBURY, L
TREIBER, FA
STRONG, WB
机构
[1] Section of Cardiology, Medical College of Georgia, Augusta, Ga
关键词
D O I
10.1016/0002-8703(90)90132-H
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study evaluated the effect of intracardiac shungting on the accuracy of thoracic bioimpedance-derived cardiac output determinations. Twenty-six patients, ranging in age from 3 months to 17 years, underwent cardiac catheterization during which simultaneous Fick and impedance measurements of cardiac output were obtained. The subjects were divided into three groups: 10 children with no intracardiac shunts, nine children with predominant left-to-right intracardiac shunts, and seven children with predominant right-to-left intracardiac shunts. Positive correlations between impedance and Fick-derived cardiac output determinations were obtained in the non-shunt group (r = 0.84), with lower correlations in the left-to-right shunt group (r = 0.70). In the right-to-left shunt group, the impedance derived cardiac output correlated with Fick pulmonary flow (r = 0.82), but the variability was unacceptably large. Although further study is needed, impedance cardiography appears to have validity as a methodology in pediatric critical care and cardiovascular health research. © 1990.
引用
收藏
页码:1166 / 1172
页数:7
相关论文
共 50 条
  • [21] INTRA-DIALYTIC MEASUREMENT OF CARDIAC-OUTPUT BY THERMODILUTION AND IMPEDANCE CARDIOGRAPHY
    HANDT, A
    FARBER, MO
    SZWED, JJ
    CLINICAL NEPHROLOGY, 1977, 7 (02) : 61 - 64
  • [22] CONTINUOUS MEASUREMENT OF CARDIAC-OUTPUT BY IMPEDANCE CARDIOGRAPHY DURING SUBMAXIMAL EXERCISE
    COX, C
    MILLSON, DS
    HOBSON, S
    HARRY, J
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1989, 28 (02) : P227 - P228
  • [23] IMPEDANCE CARDIOGRAPHY FOR CARDIAC-OUTPUT ESTIMATION IN PACEMAKER PATIENTS - REVIEW OF THE LITERATURE
    OVSYSHCHER, I
    FURMAN, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (07): : 1412 - 1422
  • [24] CARDIAC-OUTPUT BY IMPEDANCE CARDIOGRAPHY - 2 ALTERNATIVE METHODOLOGIES COMPARED WITH THERMODILUTION
    SHERWOOD, A
    CARTER, LS
    MURPHY, CA
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1991, 62 (02): : 116 - 122
  • [25] CARDIAC-OUTPUT MEASURED BY IMPEDANCE CARDIOGRAPHY DURING MAXIMAL EXERCISE TESTS
    TEO, KK
    HETHERINGTON, MD
    HAENNEL, RG
    GREENWOOD, PV
    ROSSALL, RE
    KAPPAGODA, T
    CARDIOVASCULAR RESEARCH, 1985, 19 (12) : 737 - 743
  • [26] THE ACCURACY OF IMPEDANCE CARDIOGRAPHY IN MEASUREMENT OF CARDIAC-OUTPUT IN COMPARISON WITH THERMODILUTION METHOD
    WONG, KL
    BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 : 16 - 16
  • [27] Impedance cardiography: Equivalent noninvasive alternative to thermodilution cardiac output measurement
    Van de Water, JM
    Adkison, EK
    Carswell, E
    Vogel, RL
    Dalton, ML
    FASEB JOURNAL, 2003, 17 (04): : A387 - A387
  • [28] NONINVASIVE ASSESSMENT OF CARDIAC-OUTPUT BY DOPPLER ECHOCARDIOGRAPHY
    ALI, AS
    SERGAKOVA, LM
    MAREEV, VY
    KASEY, DV
    KARDIOLOGIYA, 1988, 28 (04) : 80 - 84
  • [29] CARDIOVASCULAR CHANGES DURING LAPAROSCOPY - STUDIES OF STROKE VOLUME AND CARDIAC-OUTPUT USING IMPEDANCE CARDIOGRAPHY
    LENZ, RJ
    THOMAS, TA
    WILKINS, DG
    ANAESTHESIA, 1976, 31 (01) : 4 - 12
  • [30] ASSESSMENT OF THE CARDIAC-OUTPUT BY IMPEDANCE CARDIOGRAPHY (DIFFERENTIAL RHEOGRAPHY) TO GIVE OPTIMUM CONTINUOUS POSITIVE PRESSURE VENTILATION
    BENZER, H
    GEYER, A
    MUTZ, N
    PAUSER, G
    POLZER, K
    SCHERZER, W
    SCHUHFRIED, F
    WIENER KLINISCHE WOCHENSCHRIFT, 1979, 91 (12) : 418 - 421