Sensitivity of Electronic Portal Imaging Device (EPID) Based Transit Dosimetry to Detect Inter-fraction Patient Variations

被引:4
|
作者
Bawazeer, Omemh [1 ,2 ]
Sarasanandarajah, Sivananthan [1 ,3 ,4 ]
Herath, Sisira [3 ]
Kron, Tomas [3 ,5 ]
Deb, Pradip [1 ]
机构
[1] RMIT Univ, Discipline Med Radiat, Melbourne, Vic, Australia
[2] Umm Al Qura Univ, Discipline Sci, Mecca, Saudi Arabia
[3] Peter MacCallum Canc Ctr, Dept Phys Sci, Melbourne, Vic, Australia
[4] IAEA, Div Human Hlth, Vienna, Austria
[5] Univ Melbourne, Sir Peter MacCallum Dept Oncol, Melbourne, Vic, Australia
关键词
Transit EPID dosimetry; Patient variation SSIM index; QUALITY-ASSURANCE; RADIOTHERAPY; INCIDENTS; ERRORS;
D O I
10.1007/978-981-10-9023-3_86
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The sensitivity of EPID-based transit dosimetry to detect patient variations between treatment fractions is examined using gamma analysis and a structural similarity (SSIM) index. EPID images were acquired for 3-dimensional conformal (3DCRT) and dynamic intensity modulated (dIMRT) radiation therapy fields in multiple fractions. Transit images were converted to doses, transit dose in the first fraction considered the reference dose. Variations in patient position or weight were then introduced in the subsequent fractions. Positional variations were examined using a lung and a head and neck phantoms. Anatomical variations were examined using a slab phantom in three scenarios, with solid water simulating tissue, medium-density fiberboard simulating fat, and Styrofoam simulating lung. The dose difference between the first and subsequent fractions was computed using various gamma criteria and the SSIM index. Using a criterion of 3%/3 mm, EPID can detect positional variations >= 4 mm, and tissue and fat variations >= 1 cm, whereas it cannot detect lung variations up to 4 cm. The sensitivity for 3DCRT is higher than for dIMRT. EPID can detect the most variations when using 3%/1 mm. With the SSIM index, EPID can detect a 2 mm positional variation and 1 cm of lung variation. The factor that optimized the sensitivity of EPID was a reduction in the distance to the agreement criteria. Our study introduces the SSIM as an alternative analysis with high sensitivity for minimal variations.
引用
收藏
页码:477 / 480
页数:4
相关论文
共 50 条
  • [41] Sensitivity Analysis of An Electronic Portal Imaging Device Monte Carlo Model to Variations in Optical Transport Parameters
    Blake, S.
    Vial, P.
    Holloway, L.
    McNamara, A.
    Greer, P.
    Kuncic, Z.
    MEDICAL PHYSICS, 2012, 39 (06) : 3650 - 3650
  • [42] Application of Electronic Portal Imaging Device-based Portal Dosimetry for Evaluating Treatment Planning after Volume Changes
    Won, H. S.
    Chang, N. J.
    Choi, J. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E252 - E253
  • [43] Overview of 3-year experience with large-scale electronic portal imaging device-based 3-dimensional transit dosimetry
    Mijnheer, Ben J.
    Gonzalez, Patrick
    Olaciregui-Ruiz, Igor
    Rozendaal, Roel A.
    van Herk, Marcel
    Mans, Anton
    PRACTICAL RADIATION ONCOLOGY, 2015, 5 (06) : E679 - E687
  • [44] Imaging linear accelerator output using a high-speed scintillation based electronic portal imaging device (Hi-EPID)
    Ranade, Manisha
    Lynch, Bart
    Li, Jonathan
    Kim, Siyong
    Dempsey, James
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1811 - +
  • [45] Imaging linear accelerator startup using a high-speed scintillation based electronic portal imaging device (Hi-EPID)
    Ranade, M.
    Lynch, B.
    Li, J.
    Kim, S.
    Dempsey, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2612 - 2612
  • [46] The experience of a developing country using an electronic portal imaging device for the verification of patient positioning and dosimetry in radiotherapy for prostate cancer
    Farhat, Leila
    Fourati, N.
    Mnejja, W.
    Daoud, J.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (03) : 297 - 301
  • [47] Amorphous silicon based electronic portal imaging device (aSi-EPID) in routine QA procedures for dynamic IMRT technique
    Cordero-Ramirez, A.
    MEDICAL PHYSICS, 2007, 34 (06) : 2415 - 2415
  • [48] Initial Clinical Experience with Electronic Portal Imaging Device-Based In Vivo Dosimetry for Radiotherapy in Gynecological Cancers
    Yedekci, Yagiz
    Yuce Sari, Sezin
    Gultekin, Melis
    Yildiz, Ferah
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2022, 37 (04): : 446 - 452
  • [49] A Cross Institution Study of Anatomy Changes in Head-And-Neck Cancer Patients Using In-Vivo Electronic Portal Imaging Device (EPID) Transit Images
    Trauernicht, C.
    Steers, J.
    Bojechko, C.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [50] Evaluation of the Cumulative Signal Response with the Electronic Portal Imaging Device (EPID) and the Integral Quality Monitor (IQM) for Patient-Specific SBRT QA
    Harpley, A.
    Morales-Paliza, M.
    Price, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E774 - E775