Simultaneous Analysis of 10 Priority PAHs in Iranian Sangak Bread Samples by Developing a GC-MS Method

被引:5
|
作者
Peiravian, Farzad [1 ]
Shakoori, Attaollah [2 ]
Moradi, Vahideh [2 ]
Salamzadeh, Jamshid [3 ]
Mahboubi, Arash [4 ]
机构
[1] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Pharmacoecon & Pharma Management, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Food & Drugs Affairs, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Food Safety Res Ctr, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Pharmaceut, Tehran, Iran
来源
关键词
GC-MS; Poly Aromatic Hydrocarbons (PAHs); Sangak bread; Iran; POLYCYCLIC AROMATIC-HYDROCARBONS; PESTICIDE-RESIDUES; MASS-SPECTROMETRY; DIETARY EXPOSURE; EXTRACTION; FOOD; INJECTION;
D O I
10.22037/ijpr.2020.113074.14097
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Human exposure to polycyclic aromatic hydrocarbons (PAHs) is known as a carcinogen risk factor. In this study, a gas chromatography-mass spectrometry (GC-MS) technique combined with the QuEChERS extraction method was developed for concurrent analysis of 10 polycyclic aromatic hydrocarbons (PAHs) in Iranian traditional Sangak bread samples. The method was validated by determining different parameters, including; linearity, accuracy, precision, limit of detection (LOD) and limit of quantitation (LOQ). Calibration curves showed a linear relationship in the concentration range of 10-500 ng/g with a coefficient of determination (R-2) ranged between 0.994 and 0.999. The obtained mean recoveries were 92-106% with the relative standard deviations (RSDs) in the range of 3-7% with an acceptable precision (RSD < 20%). The Limit of detections (LODs) for different PAHs were between 0.14-0.78 ng/g, while the limit of quantitation (LOQ) was 0.46-2.60 ng/g. Matrix effect studies showed that the analytes concluded signal suppressions or enhancements. Therefore, spiked calibration curves were used for overcoming this issue. The result of Sangak bread samples analysis using the validated method showed that 9 (19.4%) out of 47 Sangak bread samples were contaminated with phenanthrene (PHE) and anthracene (ANT) at the mean level of 10.08 +/- 6.38 ng/g which were higher than the permissible limit of European Commission regulatory control value for BaP (1 mu g/kg of wet weight) in processed cereal-based foods and baby foods for infants and young children.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 50 条
  • [21] Analysis of poly-β-hydroxybutyrate in environmental samples by GC-MS/MS
    D. Elhottová
    J. Tříska
    S. O. Petersen
    H. Šantrůčková
    Fresenius' Journal of Analytical Chemistry, 2000, 367 : 157 - 164
  • [22] Analysis of poly-β-hydroxybutyrate in environmental samples by GC-MS/MS
    Elhottová, D
    Tríska, J
    Petersen, SO
    Santrucková, H
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (02): : 157 - 164
  • [23] SIMULTANEOUS ANALYSIS OF 50 PESTICIDES IN WATER SAMPLES BY SOLID-PHASE EXTRACTION AND GC-MS
    BENFENATI, E
    TREMOLADA, P
    CHIAPPETTA, L
    FRASSANITO, R
    BASSI, G
    DITORO, N
    FANELLI, R
    STELLA, G
    CHEMOSPHERE, 1990, 21 (12) : 1411 - 1421
  • [24] A New Gas Chromatography/Mass Spectrometry (GC-MS) Method for the Multiresidue Analysis of Pesticides in Bread
    Kolberg, Diana I.
    Prestes, Osmar D.
    Adaime, Martha B.
    Zanella, Renato
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2010, 21 (06) : 1065 - 1070
  • [25] Simultaneous Determination of OCPs, PCBs and PAHs in Soybean Oil Using Surfactant-Based QuEChERS Method Coupled with GC-MS/MS
    Li X.-B.
    Liu F.-G.
    Zhou C.-Y.
    Chen S.-S.
    Journal of Chinese Mass Spectrometry Society, 2019, 40 (01) : 60 - 73
  • [26] The analysis of aminoazaarenes as their derivatives with GC-MS method in the heat-processed meat samples
    Janoszka, B
    Blaszczyk, U
    Warzecha, L
    Luks-Betlej, K
    Strózyk, M
    CHEMIA ANALITYCZNA, 2003, 48 (04): : 707 - 721
  • [27] A fast and easy GC-MS/MS method for simultaneous analysis of 73 pesticide residues in vegetables and fruits
    Lu, Dan
    Yang, Yuan
    Luo, Xiaofei
    Sun, Chengjun
    ANALYTICAL METHODS, 2013, 5 (07) : 1721 - 1732
  • [28] Analysis of pesticides in water samples using GC-ECD and GC-MS/MS techniques
    Pablos-Espada, MC
    Arrebola-Liébanas, FJ
    Garrido-Frenich, A
    Martínez-Vidal, JL
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1999, 75 (1-2) : 165 - 179
  • [29] Improved sample preparation and GC-MS analysis of priority organic pollutants
    Polyakova, Olga V.
    Mazur, Dmitry M.
    Lebedev, Albert T.
    ENVIRONMENTAL CHEMISTRY LETTERS, 2014, 12 (03) : 419 - 427
  • [30] Development of a GC-MS Method for Determination of Various Polycyclic Aromatic Hydrocarbons in Iranian Traditional and Semi-industrial Taftoon Bread
    Moradi, Vahideh
    Ardabili, Seyed Mahdi Seyedain
    Shakoori, Attaollah
    Hoseyni, Seyed Ebrahim
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2020, 19 (03): : 183 - 194