Simultaneous Analysis of 10 Priority PAHs in Iranian Sangak Bread Samples by Developing a GC-MS Method

被引:5
|
作者
Peiravian, Farzad [1 ]
Shakoori, Attaollah [2 ]
Moradi, Vahideh [2 ]
Salamzadeh, Jamshid [3 ]
Mahboubi, Arash [4 ]
机构
[1] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Pharmacoecon & Pharma Management, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Food & Drugs Affairs, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Food Safety Res Ctr, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Pharmaceut, Tehran, Iran
来源
关键词
GC-MS; Poly Aromatic Hydrocarbons (PAHs); Sangak bread; Iran; POLYCYCLIC AROMATIC-HYDROCARBONS; PESTICIDE-RESIDUES; MASS-SPECTROMETRY; DIETARY EXPOSURE; EXTRACTION; FOOD; INJECTION;
D O I
10.22037/ijpr.2020.113074.14097
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Human exposure to polycyclic aromatic hydrocarbons (PAHs) is known as a carcinogen risk factor. In this study, a gas chromatography-mass spectrometry (GC-MS) technique combined with the QuEChERS extraction method was developed for concurrent analysis of 10 polycyclic aromatic hydrocarbons (PAHs) in Iranian traditional Sangak bread samples. The method was validated by determining different parameters, including; linearity, accuracy, precision, limit of detection (LOD) and limit of quantitation (LOQ). Calibration curves showed a linear relationship in the concentration range of 10-500 ng/g with a coefficient of determination (R-2) ranged between 0.994 and 0.999. The obtained mean recoveries were 92-106% with the relative standard deviations (RSDs) in the range of 3-7% with an acceptable precision (RSD < 20%). The Limit of detections (LODs) for different PAHs were between 0.14-0.78 ng/g, while the limit of quantitation (LOQ) was 0.46-2.60 ng/g. Matrix effect studies showed that the analytes concluded signal suppressions or enhancements. Therefore, spiked calibration curves were used for overcoming this issue. The result of Sangak bread samples analysis using the validated method showed that 9 (19.4%) out of 47 Sangak bread samples were contaminated with phenanthrene (PHE) and anthracene (ANT) at the mean level of 10.08 +/- 6.38 ng/g which were higher than the permissible limit of European Commission regulatory control value for BaP (1 mu g/kg of wet weight) in processed cereal-based foods and baby foods for infants and young children.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 50 条
  • [31] The analysis of linear and monomethylalkanes in exhaled breath samples by GC x GC-FID and GC-MS/MS
    Szabo, Alexandra Hengerics
    Podolec, Peter
    Ferenczy, Viktoria
    Kubinec, Robert
    Blagko, Jaroslav
    Sojak, Ladislav
    Gorova, Renata
    Addova, Gabriela
    Ostrovsky, Ivan
    Visnovsky, Jozef
    Bierhanzl, Vaclav
    Cabala, Radomir
    Amann, Anton
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 978 : 62 - 69
  • [32] GC-MS analysis of PAHs in charcoal grilled rabbit meat with and without additives
    Siddique, Rabia
    Zahoor, Ameer Fawad
    Ahmad, Sajjad
    Ahmad, Hamad
    Mansha, Asim
    Zahid, Faisal Maqbool
    Faisal, Shahla
    Aadil, Rana Muhammad
    FOOD SCIENCE AND TECHNOLOGY, 2021, 41 : 702 - 707
  • [33] GC-MS analysis of hashish samples: A case of adulteration with colophony
    Caligiani, Augusta
    Palla, Gerardo
    Bernardelli, Brenno
    JOURNAL OF FORENSIC SCIENCES, 2006, 51 (05) : 1096 - 1100
  • [34] Rapid Analysis of Complex Samples by GC-MS with Immune Algorithm
    Mei Zhen
    Cai Wen-Sheng
    Shao Xue-Guang
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2013, 34 (04): : 819 - 822
  • [35] Analysis of odorous gases with simultaneous GC-MS and sensory determination
    Orko, Inka
    Lehtomaki, Jukka
    Sandell, Erik
    Arnold, Mona
    Publications - Technical Research Centre of Finland, 1995, (1710):
  • [36] GC-MS/MS analysis of chlorpyrifos in forensic samples with varied survival time
    Tabasum, Husna
    Neelagund, S. E.
    Kotresh, K. R.
    Gowtham, M. D.
    Sulochana, N.
    FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2024, 20 (04) : 1388 - 1396
  • [37] A GC-MS method for the determination of polar organic compounds in atmospheric samples
    Limbeck, A
    Puxbaum, H
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1999, 73 (04) : 329 - 343
  • [38] GC-MS method development and validation for anabolic steroids in feed samples
    Muniz-Valencia, Roberto
    Ceballos-Magana, Silvia G.
    Gonzalo-Lumbreras, Raquel
    Santos-Montes, Ana
    Lzquierdo-Hornillos, Roberto
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (04) : 727 - 734
  • [39] Single laboratory validation of a SPE method for the determination of PAHs in edible oils by GC-MS
    Cassimiro Belo, Renata Franca
    Nunes, Carolina Mariana
    dos Santos, Eleonora Vieira
    Augusti, Daniella Vasconcellos
    Pissinatti, Rafael
    ANALYTICAL METHODS, 2012, 4 (12) : 4068 - 4076
  • [40] Simultaneous Determination of Organic Acids in Chinese Liquor by GC-MS Method
    Ma, Yanhong
    Li, Meiping
    Zhang, Shengwan
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (15) : 4707 - 4710