Analysis of poly-β-hydroxybutyrate in environmental samples by GC-MS/MS

被引:0
|
作者
D. Elhottová
J. Tříska
S. O. Petersen
H. Šantrůčková
机构
[1] Institute of Soil Biology Academy of Sciences of the Czech Republic,
[2] Na Sádkách 7,undefined
[3] 370 05 České Budějovice,undefined
[4] Czech Republic e-mail: danael@upb.cas.cz,undefined
[5] Institute of Landscape Ecology,undefined
[6] Academy of Sciences of the Czech Republic,undefined
[7] České Budějovice,undefined
[8] Czech Republic,undefined
[9] Danish Institute of Agricultural Sciences,undefined
[10] Department of Crop Physiology and Soil Science,undefined
[11] Foulum Research Centre,undefined
[12] Tjele,undefined
[13] Denmark,undefined
[14] Faculty of Biological Sciences,undefined
[15] University of South Bohemia,undefined
[16] České Budějovice,undefined
[17] Czech Republic,undefined
关键词
Sludge; Sewage Sludge; Activate Sludge; Bacillus Megaterium; Activate Sludge Sample;
D O I
暂无
中图分类号
学科分类号
摘要
Application of gas chromatography-mass spectrometry (GC-MS) can significantly improve trace analyses of compounds in complex matrices from natural environments compared to gas chromatography only. A GC-MS/MS technique for determination of poly-β-hydroxybutyrate (PHB), a bacterial storage compound, has been developed and used for analysis of two soils stored for up to 319 d, fresh samples of sewage sludge, as well as a pure culture of Bacillus megaterium. Specific derivatization ¶of β-hydroxybutyrate (3-OH C4 : 0) PHB monomer units by N-tert-butyl-dimethylsilyl-N-methyltrifluoracetamide (MTBSTFA) improved chromatographic and mass spectrometric properties of the analyte. The diagnostic fragmentation scheme of the derivates tert-butyldimethylsilyl ester and ether of β-hydroxybutyric acid (MTBSTFA-HB) essential for the PHB identification was shown. The ion trap MS was used, therefore the scan gave the best sensitivity and with MS/MS the noise decreased, so the S/N was better and also with second fragmentation the amount of ions increased compared to SIM. The detection limit for MTBSTFA-HB by GC-MS/MS was about 10–13 g μL–1 of injected volume, while by GC (FID) and GC-MS (scan) it was around 10–10 g μL–1 of injected volume. Sensitivity of GC-MS/MS measurements of PHB in arable soil and activated sludge samples was down to 10 pg of PHB g–1 dry matter. Comparison of MTBSTFA-HB detection in natural soil sample by GC (FID), GC-MS (scan) and by GC-MS/MS demonstrated potentials and limitations of the individual measurement techniques.
引用
收藏
页码:157 / 164
页数:7
相关论文
共 50 条
  • [1] Analysis of poly-β-hydroxybutyrate in environmental samples by GC-MS/MS
    Elhottová, D
    Tríska, J
    Petersen, SO
    Santrucková, H
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (02): : 157 - 164
  • [2] ANALYSIS OF SUSPECT ARSON SAMPLES BY GC AND GC-MS
    BERTSCH, W
    SELLERS, CS
    HOLZER, G
    BABIN, K
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1988, 6 (11): : 1000 - &
  • [3] GC-MS and GC-MS/MS for the analysis of endogenous and exogenous hormones
    Martinchek, Justin
    Boylan, Helen M.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U789 - U790
  • [4] GC-MS and GC-MS/MS measurement of the cardiovascular risk factor homoarginine in biological samples
    Kayacelebi, Arslan Arinc
    Beckmann, Bibiana
    Gutzki, Frank-Mathias
    Jordan, Jens
    Tsikas, Dimitrios
    AMINO ACIDS, 2014, 46 (09) : 2205 - 2217
  • [5] Comparison of enzymatic and GC-MS/MS analysis of creatinine in urine samples
    Ferenczy, Viktoria
    Kotora, Peter
    Hudecova, Dusana
    Blasko, Jaroslav
    Kubinec, Robert
    Behulova, Darina
    PROCEEDINGS OF THE 11TH INTERNATIONAL STUDENTS CONFERENCE "MODERN ANALYTICAL CHEMISTRY", 2015, : 7 - 11
  • [6] Recent developments in sample preparation and GC-MS/MS analysis of environmental contaminants and pesticides in food samples
    Sapozhnikova, Yelena
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250
  • [7] THE APPLICATION OF GC-MS IN ENVIRONMENTAL-ANALYSIS
    SCHNUTE, WC
    SMITH, DE
    AMERICAN LABORATORY, 1980, 12 (07) : 87 - &
  • [8] THE APPLICATION OF GC-MS IN ENVIRONMENTAL-ANALYSIS
    SCHNUTE, WC
    SMITH, DE
    INTERNATIONAL LABORATORY, 1980, 10 (06): : 75 - &
  • [9] Comparison of MEKC-UV and GC-MS in the analysis of explosives in environmental samples
    Genzman, Ashton
    Rine, Jacqueline
    Brensinger, Karen
    Rollman, Christopher
    Lurie, Ira
    Moini, Mehdi
    Copper, Christine
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [10] Quadrupole GC-MS analysis of polybrominated diphenyl ethers (PBDE) in environmental samples
    Cole, J
    Phillips, E
    Conoley, M
    LC GC NORTH AMERICA, 2005, : 45 - 45