Rapid decline in acute stimulation thresholds with steroid-eluting active-fixation pacing leads

被引:33
|
作者
Kistler, PM [1 ]
Kalman, JM [1 ]
Fynn, SP [1 ]
Singarayar, S [1 ]
Roberts-Thomson, KC [1 ]
Lindsay, CB [1 ]
Khong, U [1 ]
Sparks, PB [1 ]
Strathmore, N [1 ]
Mond, HG [1 ]
机构
[1] Royal Melbourne Hosp, Dept Cardiol, Melbourne, Vic 3050, Australia
来源
关键词
pacing; pacemakers; surgery;
D O I
10.1111/j.1540-8159.2005.00209.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rapid Decline in Acute Stimulation Thresholds with Steroid-Eluting Active-Fixation Pacing Leads. Background and Aim: There is an increasing use of active-fixation leads for cardiac pacing, yet concerns remain regarding initial high stimulation thresholds. The aim was to perform a detailed analysis of pacing parameters at the time of implantation to determine when lead repositioning should be considered. Methods: We performed a prospective observational study of consecutive new pacemaker implants. Detailed analysis of pacing parameters was collected at 2-minute intervals for 10 minutes, and at day 1 and week 8 following implant. Results: Ninety-four patients underwent implantation of 79 dual-chamber and 15 single-chamber pacemakers using active-fixation leads in both chambers. An initial threshold of > 1 V was demonstrated in 45194 (48%) ventricular leads (mean threshold 1.5 +/- 0.3 V). This declined rapidly to 0.9 +/- 0.3 V at 4 minutes (P < 0.01), 0.7 +/- 0.3 V at 10 minutes (P < 0.01), and 0.6 +/- 0.3 V at day 1 (P < 0.01). At day 1, 43145 leads were < 1 V There were 79 atrial leads. An initial threshold of > 1 V (mean 1.7 +/- 0.6 V) was demonstrated in 41/79 (52%) leadsfalling significantly to 1.1 +/- 0.5 V at 4 minutes (P < 0.01), 0.9 +/- 0.4 V at 10 minutes (P < 0.01), and 0.6 +/- 0.2 V at day 1 (P < 0.01). At 10 minutes, 32 of 41 leads demonstrated a threshold of < 1 V with all leads < 1 V at day 1. Thresholds were maintained medium term. Conclusions: Active-fixation leads are commonly associated with initially high thresholds that fall rapidly. An initial threshold of 2 V should be provisionally accepted and retested at 4 minutes. The majority will have a threshold of < 1 V the following day. A failure of a high threshold to decline at 4 minutes requires lead repositioning.
引用
收藏
页码:903 / 909
页数:7
相关论文
共 50 条
  • [1] Low chronic pacing thresholds of steroid-eluting active-fixation ventricular pacemaker leads: A useful alternative to passive-fixation leads
    Hidden-Lucet, F
    Halimi, F
    Gallais, Y
    Petitot, JC
    Fontaine, G
    Frank, R
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (11): : 1798 - 1800
  • [2] Comparison between active and passive fixation in steroid-eluting atrial pacing leads
    Schuchert, A
    vanLangen, H
    Michels, K
    Meinertz, T
    ZEITSCHRIFT FUR KARDIOLOGIE, 1996, 85 (04): : 255 - 259
  • [3] EARLY PERFORMANCE OF A NOVEL STEROID-ELUTING ACTIVE-FIXATION PERMANENT PACEMAKER LEAD
    CROSSLEY, GH
    MATISTA, JF
    KIGER, LA
    HAISTY, WK
    FITZGERALD, DM
    CLINICAL RESEARCH, 1992, 40 (04): : A776 - A776
  • [4] Failure of the Active-Fixation Mechanism during Removal of Active-Fixation Pacing Leads
    Cano, Oscar
    Osca, Joaquin
    Sancho-Tello, Maria-Jose
    Olaguee, Jose
    Castro, Jose E.
    Salvador, Antonio
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (10): : 1217 - 1224
  • [5] Activated pyrolytic carbon tip pacing leads: An alternative to steroid-eluting pacing leads?
    Masini, M
    Lazzari, M
    Lorenzoni, R
    Domicelli, AM
    Micheletti, A
    Dianda, R
    Masini, G
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11): : 1832 - 1835
  • [6] Acute performance of steroid-eluting screw-in leads for atrial free wall pacing
    Nakazato, Y
    Nakata, Y
    Mineta, Y
    Nakazato, K
    Yasuda, M
    Sumiyoshi, M
    Yamaguchi, H
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1999, 63 (07): : 514 - 516
  • [7] Steroid-eluting and fractally coated electrodes in children with high pacing thresholds
    Sinha, AM
    Breithardt, OA
    Vazquez-Jimenez, JF
    Birkenhauer, F
    Schauerte, P
    Stellbrink, C
    THORACIC AND CARDIOVASCULAR SURGEON, 2002, 50 (04): : 247 - 249
  • [8] ACUTE AND LONG-TERM ATRIAL AND VENTRICULAR STIMULATION THRESHOLDS WITH A STEROID-ELUTING ELECTRODE
    KRUSE, IM
    TERPSTRA, B
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (01): : 45 - 49
  • [9] A comparison of steroid-eluting epicardial versus transvenous pacing leads in children
    Dodge-Khatami, A
    Johnsrude, CL
    Backer, CL
    Deal, BJ
    Strasberger, J
    Mavroudis, C
    JOURNAL OF CARDIAC SURGERY, 2000, 15 (05) : 323 - 329
  • [10] Programmable polarity: Effects on pacing and sensing of bipolar steroid-eluting leads
    Schuchert, A
    Cappato, R
    Kuck, KH
    Meinertz, T
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (12): : 2099 - 2102