Rapid decline in acute stimulation thresholds with steroid-eluting active-fixation pacing leads

被引:33
|
作者
Kistler, PM [1 ]
Kalman, JM [1 ]
Fynn, SP [1 ]
Singarayar, S [1 ]
Roberts-Thomson, KC [1 ]
Lindsay, CB [1 ]
Khong, U [1 ]
Sparks, PB [1 ]
Strathmore, N [1 ]
Mond, HG [1 ]
机构
[1] Royal Melbourne Hosp, Dept Cardiol, Melbourne, Vic 3050, Australia
来源
关键词
pacing; pacemakers; surgery;
D O I
10.1111/j.1540-8159.2005.00209.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rapid Decline in Acute Stimulation Thresholds with Steroid-Eluting Active-Fixation Pacing Leads. Background and Aim: There is an increasing use of active-fixation leads for cardiac pacing, yet concerns remain regarding initial high stimulation thresholds. The aim was to perform a detailed analysis of pacing parameters at the time of implantation to determine when lead repositioning should be considered. Methods: We performed a prospective observational study of consecutive new pacemaker implants. Detailed analysis of pacing parameters was collected at 2-minute intervals for 10 minutes, and at day 1 and week 8 following implant. Results: Ninety-four patients underwent implantation of 79 dual-chamber and 15 single-chamber pacemakers using active-fixation leads in both chambers. An initial threshold of > 1 V was demonstrated in 45194 (48%) ventricular leads (mean threshold 1.5 +/- 0.3 V). This declined rapidly to 0.9 +/- 0.3 V at 4 minutes (P < 0.01), 0.7 +/- 0.3 V at 10 minutes (P < 0.01), and 0.6 +/- 0.3 V at day 1 (P < 0.01). At day 1, 43145 leads were < 1 V There were 79 atrial leads. An initial threshold of > 1 V (mean 1.7 +/- 0.6 V) was demonstrated in 41/79 (52%) leadsfalling significantly to 1.1 +/- 0.5 V at 4 minutes (P < 0.01), 0.9 +/- 0.4 V at 10 minutes (P < 0.01), and 0.6 +/- 0.2 V at day 1 (P < 0.01). At 10 minutes, 32 of 41 leads demonstrated a threshold of < 1 V with all leads < 1 V at day 1. Thresholds were maintained medium term. Conclusions: Active-fixation leads are commonly associated with initially high thresholds that fall rapidly. An initial threshold of 2 V should be provisionally accepted and retested at 4 minutes. The majority will have a threshold of < 1 V the following day. A failure of a high threshold to decline at 4 minutes requires lead repositioning.
引用
收藏
页码:903 / 909
页数:7
相关论文
共 50 条
  • [41] CLINICAL COMPARISON OF LOW THRESHOLD PLATINIZED AND NEW STEROID-ELUTING PLATINIZED TRANSVENOUS PACING LEADS IN CHILDREN
    KARPAWICH, PP
    HAKIMI, M
    CAVITT, DL
    SCHALLHORN, R
    AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (05): : 423 - 423
  • [42] Clinical evaluation of a new steroid-eluting single coil defibrillation lead for active fixation
    Binner, L.
    Stiller, S.
    Stiller, P.
    Brummer, T.
    Grossmann, G.
    EUROPEAN HEART JOURNAL, 2006, 27 : 461 - 462
  • [43] The indications and safety of prolonged temporary pacing using active-fixation leads and externalized pulse generator
    Shah, Nisar H.
    Shah, Parin
    Elsayed, Hossam
    O'Callaghan, Peter
    Leong, Fong T.
    Yousef, Zaheer
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (03): : 506 - 512
  • [44] Initial clinical experience with steroid eluting, titanium nitride passive fixation pacing leads
    Crawford, W
    Gentzler, R
    Klein, S
    Tyler, J
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 551 - 555
  • [45] TREATMENT OF PATIENTS WITH PRIOR EXIT BLOCK USING A NOVEL STEROID-ELUTING ACTIVE FIXATION LEAD
    CROSSLEY, GH
    REYNOLDS, D
    KAY, GN
    FERGUSON, TB
    LAMAS, G
    MESSENGER, J
    ZMIJEWSKI, M
    BRINKER, JA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 2042 - 2046
  • [46] Acute Changes in the Pacing Threshold After Lead Implantation Comparison Between Retractable and Sweet-Tip Active-Fixation Leads
    Kashiwase, Kazunori
    Kobayashi, Hiroshi
    Hirata, Akio
    Wada, Mitsuru
    Nakanishi, Hiroyuki
    Ueda, Yasunori
    INTERNATIONAL HEART JOURNAL, 2012, 53 (02) : 108 - 112
  • [47] Comparison of longevity, paging, and sensing characteristics of steroid-eluting epicardial versus conventional endocardial pacing leads in children
    Beaufort-Krol, GCM
    Mulder, H
    Nagelkerke, D
    Waterbolk, TW
    Bink-Boelkens, MTE
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 117 (03): : 523 - 528
  • [48] STEROID-ELUTING LEADS - 4-YEAR-FOLLOW-UP OF PACING THRESHOLD, IMPEDANCE, AND INTRACARDIAC VENTRICULAR SIGNAL
    SCHUCHERT, A
    KUCK, KH
    HERZ KREISLAUF, 1993, 25 (09): : 289 - 291
  • [49] Long-term clinical experience with a steroid-eluting active fixation ventricular electrode in children
    Celiker, A
    Alehan, D
    Oto, A
    Ozme, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (03): : 355 - &
  • [50] A long-term, prospective, cohort study on the performance of right ventricular pacing leads: comparison of active-fixation with passive-fixation leads
    Liu, Lie
    Tang, Jiaojiao
    Peng, Hu
    Wu, Shulin
    Lin, Chunying
    Chen, Dongli
    Zhang, Qianhuan
    Liang, Yuanhong
    Chen, Silin
    Chen, Yan
    Wei, Huiqiang
    SCIENTIFIC REPORTS, 2015, 5