Rapid decline in acute stimulation thresholds with steroid-eluting active-fixation pacing leads

被引:33
|
作者
Kistler, PM [1 ]
Kalman, JM [1 ]
Fynn, SP [1 ]
Singarayar, S [1 ]
Roberts-Thomson, KC [1 ]
Lindsay, CB [1 ]
Khong, U [1 ]
Sparks, PB [1 ]
Strathmore, N [1 ]
Mond, HG [1 ]
机构
[1] Royal Melbourne Hosp, Dept Cardiol, Melbourne, Vic 3050, Australia
来源
关键词
pacing; pacemakers; surgery;
D O I
10.1111/j.1540-8159.2005.00209.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rapid Decline in Acute Stimulation Thresholds with Steroid-Eluting Active-Fixation Pacing Leads. Background and Aim: There is an increasing use of active-fixation leads for cardiac pacing, yet concerns remain regarding initial high stimulation thresholds. The aim was to perform a detailed analysis of pacing parameters at the time of implantation to determine when lead repositioning should be considered. Methods: We performed a prospective observational study of consecutive new pacemaker implants. Detailed analysis of pacing parameters was collected at 2-minute intervals for 10 minutes, and at day 1 and week 8 following implant. Results: Ninety-four patients underwent implantation of 79 dual-chamber and 15 single-chamber pacemakers using active-fixation leads in both chambers. An initial threshold of > 1 V was demonstrated in 45194 (48%) ventricular leads (mean threshold 1.5 +/- 0.3 V). This declined rapidly to 0.9 +/- 0.3 V at 4 minutes (P < 0.01), 0.7 +/- 0.3 V at 10 minutes (P < 0.01), and 0.6 +/- 0.3 V at day 1 (P < 0.01). At day 1, 43145 leads were < 1 V There were 79 atrial leads. An initial threshold of > 1 V (mean 1.7 +/- 0.6 V) was demonstrated in 41/79 (52%) leadsfalling significantly to 1.1 +/- 0.5 V at 4 minutes (P < 0.01), 0.9 +/- 0.4 V at 10 minutes (P < 0.01), and 0.6 +/- 0.2 V at day 1 (P < 0.01). At 10 minutes, 32 of 41 leads demonstrated a threshold of < 1 V with all leads < 1 V at day 1. Thresholds were maintained medium term. Conclusions: Active-fixation leads are commonly associated with initially high thresholds that fall rapidly. An initial threshold of 2 V should be provisionally accepted and retested at 4 minutes. The majority will have a threshold of < 1 V the following day. A failure of a high threshold to decline at 4 minutes requires lead repositioning.
引用
收藏
页码:903 / 909
页数:7
相关论文
共 50 条
  • [31] ASSESSMENT OF LONG-TERM STABILITY OF CHRONIC VENTRICULAR PACING THRESHOLDS IN STEROID-ELUTING ELECTRODES
    STOJANOV, P
    DJORDJEVIC, M
    VELIMIROVIC, D
    BELKIC, K
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (10): : 1417 - 1420
  • [32] Stable electrical performance of high efficiency pacing leads having small surface, steroid-eluting pacing electrodes
    Deshmukh, P
    Casavant, D
    Anderson, K
    Romanyshyn, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (11): : 1599 - 1603
  • [33] Long-term follow up of bipolar steroid-eluting epicardial pacing leads in children
    Tomaske, M.
    Gerritse, B.
    Kretzers, L.
    Pretre, R.
    Dodge-Khatami, A.
    Rahn, M.
    Bauersfeld, U.
    EUROPEAN HEART JOURNAL, 2007, 28 : 642 - 642
  • [34] COMPARISON OF 2ND AND 3RD-GENERATION STEROID-ELUTING PACING LEADS
    BERSOHN, MM
    PANZER, SB
    CLINICAL RESEARCH, 1994, 42 (01): : A99 - A99
  • [35] Intrapatient comparison of atrial and ventricular sensing, pacing threshold, and impedance: Benefits with steroid-eluting leads
    Moracchini, PV
    Tesorieri, MC
    Giuliani, M
    Alfano, G
    DeSeta, F
    Boschi, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (10): : 1482 - 1487
  • [36] Long-term follow up of bipolar steroid-eluting epicardial pacing leads in children
    Dodge-Khatami, A.
    Tomaske, M.
    Rahn, M.
    Pretre, R.
    Bauersfeld, U.
    BRITISH JOURNAL OF SURGERY, 2007, 94 (06) : 784 - 784
  • [37] Are steroid-eluting cardiac pacing leads really beneficial in the pediatric and young adult age group?
    Moak, JP
    Freedenberg, V
    Patel, KM
    Beder, SD
    Kuehl, KS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 482A - 482A
  • [38] STEROID-ELUTING EPICARDIAL LEADS IN PEDIATRICS - IMPROVED EPICARDIAL THRESHOLDS IN THE 1ST YEAR
    HAMILTON, R
    GOW, R
    BAHORIC, B
    GRIFFITHS, J
    FREEDOM, R
    WILLIAMS, W
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11): : 2066 - 2072
  • [39] Right Ventricular Septal Pacing: The Success of Stylet-Driven Active-Fixation Leads
    Rosso, Raphael
    Teh, Andrew W.
    Medi, Caroline
    Hung, Thuy To
    Balasubramaniam, Richard
    Mond, Harry G.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (01): : 49 - 53
  • [40] STEROID ELUTION IMPROVES THE STIMULATION THRESHOLD IN AN ACTIVE-FIXATION ATRIAL PERMANENT PACING LEAD - A RANDOMIZED, CONTROLLED-STUDY
    CROSSLEY, GH
    BRINKER, JA
    REYNOLDS, D
    SPENCER, W
    JOHNSON, WB
    HURD, H
    TONDER, L
    ZMIJEWSKI, M
    CIRCULATION, 1995, 92 (10) : 2935 - 2939