Programmable polarity: Effects on pacing and sensing of bipolar steroid-eluting leads

被引:1
|
作者
Schuchert, A [1 ]
Cappato, R [1 ]
Kuck, KH [1 ]
Meinertz, T [1 ]
机构
[1] GEN HOSP ST GEORG,MED CLIN 2,HAMBURG,GERMANY
来源
关键词
cardiac pacemaker; steroid-eluting leads; programmable polarity; pacing; sensing;
D O I
10.1111/j.1540-8159.1996.tb03284.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Presently available bipolar pacemakers connected to bipolar leads allow the programming of polarity to either bipolar or unipolar configuration. The bipolar configuration improves sensing because of its lack of oversensing. In respect to the pacing impulse, it may be beneficial to program the bipolar to unipolar configuration, because the unipolar pacing configuration seems to lead to lower pacing thresholds. The aim of the study was to investigate the effects of the two configurations on pacing and sensing in 11 patients with a new ventricular steroid-eluting lead (Encor Dec 033-301, Telectronics Inc.) connected to the same types of VVI(R) pacemakers. Follow-up was 12 months after implantation. Pacing was assessed by pulse duration thresholds at 0.8-, 1.6-, and 2.5-V pulse amplitude and by pacing impedance. Parameters for sensing included sensing thresholds; R wave amplitudes, and amplitude of intrinsic deflection. Pulse duration thresholds were similar for the two configurations. At implantation, pacing impedance was significantly higher with bipolar (672 +/- 60 Omega) than with unipolar pacing configuration (626 +/- 82 Omega, P < 0.005). The difference lasted until 1 month after implantation (bipolar: 670 +/- 49 SZ; unipolar: 630 53 Omega, P < 0.01). No significant differences were detected after 3 (bipolar: 683 +/- 63 Omega; unipolar: 662 +/- 70 Omega) and 12 months (bipolar: 658 +/- 64 Omega; unipolar: 660 +/- 63 Omega) between the 2 configurations. Although intrinsic deflections of ventricular electrograms were different, mean R wave amplitudes were similar in unipolar and bipolar configuration. Pacing and sensing characteristics of unipolar and bipolar configuration were similar for the studied bipolar pacing lead. Pacing impedance was initially higher for bipolar than for unipolar configuration and equilibrated within 3 months after implantation.
引用
收藏
页码:2099 / 2102
页数:4
相关论文
共 50 条
  • [1] A 12-year experience of bipolar steroid-eluting epicardial pacing leads in children
    Tomaske, Maren
    Gerritse, Bart
    Kretzers, Leo
    Pretre, Rene
    Dodge-Khatami, Ali
    Rahn, Mariette
    Bauersfeld, Urs
    ANNALS OF THORACIC SURGERY, 2008, 85 (05): : 1704 - 1711
  • [2] THE LATE EFFECTS OF STEROID-ELUTING LEADS
    TIMMIS, GC
    PARSONNET, V
    GORDON, S
    WESTVEER, DC
    STEWART, JR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (02) : A3 - A3
  • [3] Activated pyrolytic carbon tip pacing leads: An alternative to steroid-eluting pacing leads?
    Masini, M
    Lazzari, M
    Lorenzoni, R
    Domicelli, AM
    Micheletti, A
    Dianda, R
    Masini, G
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11): : 1832 - 1835
  • [4] Long-term follow up of bipolar steroid-eluting epicardial pacing leads in children
    Tomaske, M.
    Gerritse, B.
    Kretzers, L.
    Pretre, R.
    Dodge-Khatami, A.
    Rahn, M.
    Bauersfeld, U.
    EUROPEAN HEART JOURNAL, 2007, 28 : 642 - 642
  • [5] Long-term follow up of bipolar steroid-eluting epicardial pacing leads in children
    Dodge-Khatami, A.
    Tomaske, M.
    Rahn, M.
    Pretre, R.
    Bauersfeld, U.
    BRITISH JOURNAL OF SURGERY, 2007, 94 (06) : 784 - 784
  • [6] Intrapatient comparison of atrial and ventricular sensing, pacing threshold, and impedance: Benefits with steroid-eluting leads
    Moracchini, PV
    Tesorieri, MC
    Giuliani, M
    Alfano, G
    DeSeta, F
    Boschi, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (10): : 1482 - 1487
  • [7] A comparison of steroid-eluting epicardial versus transvenous pacing leads in children
    Dodge-Khatami, A
    Johnsrude, CL
    Backer, CL
    Deal, BJ
    Strasberger, J
    Mavroudis, C
    JOURNAL OF CARDIAC SURGERY, 2000, 15 (05) : 323 - 329
  • [8] Bipolar vs unipolar pacing in steroid eluting leads
    Cornacchia, D
    Fabbri, M
    Moracchini, PV
    Bernasconi, M
    Nastasi, M
    Puglisi, A
    Menozzi, C
    Mascioli, G
    Nigro, P
    Adornato, E
    Pettini, A
    Marotta, T
    Corte, T
    DeSeta, F
    Tesorieri, MC
    Baraldi, P
    Marzegalli, M
    Piane, C
    Lolli, G
    Bottoni, N
    Ricci, R
    Neja, CP
    Catanzariti, D
    Adornato, ME
    Scire, A
    Sbardellati, P
    Turelli, A
    Roma, F
    Sorrentino, F
    Bendini, A
    Laudadio, MT
    PACEMAKER LEADS 1997, 1997, : 415 - 418
  • [9] STEROID-ELUTING EPICARDIAL PACING LEADS - AN ALTERNATIVE TO TRANSVENOUS LEADS IN YOUNG-PATIENTS
    JOHNS, JA
    FISH, FA
    GROSS, JP
    BURGER, JD
    STEWART, JR
    CIRCULATION, 1995, 92 (08) : 3397 - 3397
  • [10] A survival analysis of bipolar steroid-eluting and unipolar nonsteroid-eluting epicardial leads
    Fazelifar, Amir Farjam
    Taghavyan, Nina Jalily
    Moeeni, Mahdi
    Baharestani, Bahador
    Shahandashti, Farshad Jalili
    Haghjoo, Majid
    Hoseini, Saeed
    Kamali, Farzad
    Madadi, Shabnam
    Yoonesi, Ali Asghar
    Koolaji, Sogol
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (01) : 209 - 218