Programmable polarity: Effects on pacing and sensing of bipolar steroid-eluting leads

被引:1
|
作者
Schuchert, A [1 ]
Cappato, R [1 ]
Kuck, KH [1 ]
Meinertz, T [1 ]
机构
[1] GEN HOSP ST GEORG,MED CLIN 2,HAMBURG,GERMANY
来源
关键词
cardiac pacemaker; steroid-eluting leads; programmable polarity; pacing; sensing;
D O I
10.1111/j.1540-8159.1996.tb03284.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Presently available bipolar pacemakers connected to bipolar leads allow the programming of polarity to either bipolar or unipolar configuration. The bipolar configuration improves sensing because of its lack of oversensing. In respect to the pacing impulse, it may be beneficial to program the bipolar to unipolar configuration, because the unipolar pacing configuration seems to lead to lower pacing thresholds. The aim of the study was to investigate the effects of the two configurations on pacing and sensing in 11 patients with a new ventricular steroid-eluting lead (Encor Dec 033-301, Telectronics Inc.) connected to the same types of VVI(R) pacemakers. Follow-up was 12 months after implantation. Pacing was assessed by pulse duration thresholds at 0.8-, 1.6-, and 2.5-V pulse amplitude and by pacing impedance. Parameters for sensing included sensing thresholds; R wave amplitudes, and amplitude of intrinsic deflection. Pulse duration thresholds were similar for the two configurations. At implantation, pacing impedance was significantly higher with bipolar (672 +/- 60 Omega) than with unipolar pacing configuration (626 +/- 82 Omega, P < 0.005). The difference lasted until 1 month after implantation (bipolar: 670 +/- 49 SZ; unipolar: 630 53 Omega, P < 0.01). No significant differences were detected after 3 (bipolar: 683 +/- 63 Omega; unipolar: 662 +/- 70 Omega) and 12 months (bipolar: 658 +/- 64 Omega; unipolar: 660 +/- 63 Omega) between the 2 configurations. Although intrinsic deflections of ventricular electrograms were different, mean R wave amplitudes were similar in unipolar and bipolar configuration. Pacing and sensing characteristics of unipolar and bipolar configuration were similar for the studied bipolar pacing lead. Pacing impedance was initially higher for bipolar than for unipolar configuration and equilibrated within 3 months after implantation.
引用
收藏
页码:2099 / 2102
页数:4
相关论文
共 50 条
  • [41] Effectiveness of epicardial atrial pacing using a bipolar steroid-eluting endocardial lead with active fixation in an experimental model
    SCP Bueno
    WT Tamaki
    MFA Silva
    CM Zambolim
    KR Silva
    M Martinelli Filho
    R Costa
    FB Jatene
    Journal of Cardiothoracic Surgery, 8 (Suppl 1)
  • [42] Chronic steroid-eluting lead performance: A comparison of atrial and ventricular pacing
    Hua, W
    Mond, HG
    Strathmore, N
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (01): : 17 - 24
  • [43] Long-term performance of transvenous, steroid-eluting, high impedance, passive-fixation ventricular pacing leads
    Yeh, KH
    Wang, CC
    Wen, MS
    Chou, CC
    Yeh, SJ
    Wu, DL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (10): : 1399 - 1404
  • [44] CHRONIC VENTRICULAR ELECTROGRAMS - DO STEROID-ELUTING LEADS DIFFER FROM CONVENTIONAL LEADS
    SCHUCHERT, A
    HOPF, M
    KUCK, KH
    BLEIFELD, W
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (12): : 1879 - 1882
  • [45] Biphasic endocardial defibrillation raises the pacing threshold in a steroid-eluting ICD lead
    Welch, PJ
    Joglar, JA
    Zagrodsky, JD
    Sheehan, CJ
    Nelson, LL
    Parker, FW
    Hamdan, MH
    Page, RL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 513A - 514A
  • [46] LONG-TERM PERFORMANCE OF ENDOCARDIAL LEADS WITH STEROID-ELUTING ELECTRODES
    KRUSE, IM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06): : 1217 - 1219
  • [47] Pacing impedance variability in tined steroid eluting leads
    Danilovic, D
    Ohm, OJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (07): : 1356 - 1363
  • [48] Pacing impedance variability in tined steroid eluting leads
    Danilovic, D
    Ohm, OJ
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 709 - 712
  • [49] Clinical surveillance of a tined, bipolar, J-shaped, steroid-eluting, silicone-insulated atrial pacing lead
    Glikson, M
    Hyberger, LK
    Hitzke, MK
    Kincaid, DK
    Hayes, DL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (07): : 1079 - 1081
  • [50] Low chronic pacing thresholds of steroid-eluting active-fixation ventricular pacemaker leads: A useful alternative to passive-fixation leads
    Hidden-Lucet, F
    Halimi, F
    Gallais, Y
    Petitot, JC
    Fontaine, G
    Frank, R
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (11): : 1798 - 1800