Programmable polarity: Effects on pacing and sensing of bipolar steroid-eluting leads

被引:1
|
作者
Schuchert, A [1 ]
Cappato, R [1 ]
Kuck, KH [1 ]
Meinertz, T [1 ]
机构
[1] GEN HOSP ST GEORG,MED CLIN 2,HAMBURG,GERMANY
来源
关键词
cardiac pacemaker; steroid-eluting leads; programmable polarity; pacing; sensing;
D O I
10.1111/j.1540-8159.1996.tb03284.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Presently available bipolar pacemakers connected to bipolar leads allow the programming of polarity to either bipolar or unipolar configuration. The bipolar configuration improves sensing because of its lack of oversensing. In respect to the pacing impulse, it may be beneficial to program the bipolar to unipolar configuration, because the unipolar pacing configuration seems to lead to lower pacing thresholds. The aim of the study was to investigate the effects of the two configurations on pacing and sensing in 11 patients with a new ventricular steroid-eluting lead (Encor Dec 033-301, Telectronics Inc.) connected to the same types of VVI(R) pacemakers. Follow-up was 12 months after implantation. Pacing was assessed by pulse duration thresholds at 0.8-, 1.6-, and 2.5-V pulse amplitude and by pacing impedance. Parameters for sensing included sensing thresholds; R wave amplitudes, and amplitude of intrinsic deflection. Pulse duration thresholds were similar for the two configurations. At implantation, pacing impedance was significantly higher with bipolar (672 +/- 60 Omega) than with unipolar pacing configuration (626 +/- 82 Omega, P < 0.005). The difference lasted until 1 month after implantation (bipolar: 670 +/- 49 SZ; unipolar: 630 53 Omega, P < 0.01). No significant differences were detected after 3 (bipolar: 683 +/- 63 Omega; unipolar: 662 +/- 70 Omega) and 12 months (bipolar: 658 +/- 64 Omega; unipolar: 660 +/- 63 Omega) between the 2 configurations. Although intrinsic deflections of ventricular electrograms were different, mean R wave amplitudes were similar in unipolar and bipolar configuration. Pacing and sensing characteristics of unipolar and bipolar configuration were similar for the studied bipolar pacing lead. Pacing impedance was initially higher for bipolar than for unipolar configuration and equilibrated within 3 months after implantation.
引用
收藏
页码:2099 / 2102
页数:4
相关论文
共 50 条
  • [31] STEROID-ELUTING ENDOCARDIAL PACING LEAD FOR TREATMENT OF EXIT BLOCK
    KING, DH
    GILLETTE, PC
    SHANNON, C
    CUDDY, TE
    AMERICAN HEART JOURNAL, 1983, 106 (06) : 1438 - 1440
  • [32] IMPROVED EPIMYOCARDIAL PACING - INITIAL EXPERIENCE WITH A NEW BIPOLAR, STEROID-ELUTING, HIGH IMPEDANCE LEAD DESIGN
    KARPAWICH, PP
    STOKES, KB
    PROCTOR, K
    SCHALLHORN, R
    MCVENES, R
    FACTKOR, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 2032 - 2037
  • [33] LONG TERM PERFORMANCE OF STEROID-ELUTING LEAD IN DUAL CHAMBER PACING
    华伟
    Harry Mond
    ChineseMedicalSciencesJournal, 1997, (02) : 118 - 120
  • [34] STEROID-ELUTING LEADS - 4-YEAR-FOLLOW-UP OF PACING THRESHOLD, IMPEDANCE, AND INTRACARDIAC VENTRICULAR SIGNAL
    SCHUCHERT, A
    KUCK, KH
    HERZ KREISLAUF, 1993, 25 (09): : 289 - 291
  • [35] A COMPARISON OF THRESHOLD PERFORMANCE IN BIPOLAR AND UNIPOLAR STEROID-ELUTING ELECTRODES
    CUDDY, TE
    RABSON, JLR
    BUCHER, DR
    PARROTT, JC
    CHURCH, TR
    WILLIAMS, TM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (02): : 435 - 435
  • [36] Effectiveness of epicardial atrial pacing using a bipolar steroid-eluting endocardial lead with active fixation in an experimental model
    Pereira Bueno, Savia Christina
    Tamaki, Wagner Tetsuji
    Alexandrino da Silva, Marcelo Fiorelli
    Zambolim, Cristiane Maciel
    da Silva, Katia Regina
    Martinelli Filho, Martino
    Costa, Roberto
    ACTA CIRURGICA BRASILEIRA, 2013, 28 (07) : 543 - 550
  • [37] Steroid-eluting and fractally coated electrodes in children with high pacing thresholds
    Sinha, AM
    Breithardt, OA
    Vazquez-Jimenez, JF
    Birkenhauer, F
    Schauerte, P
    Stellbrink, C
    THORACIC AND CARDIOVASCULAR SURGEON, 2002, 50 (04): : 247 - 249
  • [38] Experience with a higher impedance, fixed helix, steroid-eluting pacing lead
    Giudici, MC
    Lee, M
    Higgins, S
    West, GR
    Moeller, AK
    Decker, JB
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (07): : 1103 - 1108
  • [39] Electrophysiological characteristics of bipolar membrane carbon leads with and without steroid elution compared with a conventional carbon and a steroid-eluting platinum lead
    Wiegand, UKH
    Potratz, J
    Luninghake, F
    Taubert, G
    Brandes, A
    Diederich, KW
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (08): : 1155 - 1161
  • [40] Fibrotic capsule estimation for a steroid-eluting screw-in pacing electrode
    Rawling, DA
    Amundson, DC
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 1119 - 1122