Construct validity in a high-fidelity prostate exam simulator

被引:17
|
作者
Kowalik, C. G. [2 ]
Gerling, G. J. [3 ]
Lee, A. J. [3 ]
Carson, W. C. [3 ]
Harper, J. [4 ,5 ]
Moskaluk, C. A. [4 ,5 ]
Krupski, T. L. [1 ]
机构
[1] Univ Virginia, Dept Urol, Charlottesville, VA USA
[2] Lahey Clin Med Ctr, Dept Urol, Boston, MA USA
[3] Univ Virginia, Dept Syst & Informat Engn, Charlottesville, VA USA
[4] Univ Virginia, Dept Pathol, Charlottesville, VA 22903 USA
[5] Univ Virginia, Dept Biochem & Mol Genet, Charlottesville, VA USA
关键词
simulator; elasticity; digital rectal exam; construct validity; education; DIGITAL RECTAL EXAMINATION; CANCER; STUDENTS; DESIGN;
D O I
10.1038/pcan.2011.38
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BACKGROUND: All health care practitioners should be facile in the digital rectal exam (DRE) as it provides prostate, rectal and neurological information. The purpose of this study was first to justify our hypothesis that tissue elasticity is indicative of carcinomatous changes. Second, we employed urological surgeons to evaluate our prostate simulator in three ways: (1) authenticate that the elasticity of the simulated prostates accurately represents the range of normal prostate stiffness, (2) determine the range of nodule size reasonably palpable by DRE and (3) discern what degree of elasticity difference within the same prostate suggests malignancy. METHODS: Institutional Review Board-approved materials characterization, human-subjects experiments, histopathology and chart abstraction of clinical history were performed. Material characterization of 21 ex-vivo prostatectomy specimens was evaluated using a custom-built, portable spherical indentation device while a novel prostate simulator was employed to measure human-subject perception of prostatic state. RESULTS: From the materials characterization, the measurements of the 21 gross prostates and 40 cross-sections yielded 306 data points. Within the same prostate, cancer was always stiffer. Of the seven cases with an abnormal DRE, the DRE accurately identified adenocarcinoma in 85%. From the human-subjects experiments, the simulated prostates evaluated by urologists ranged in stiffness from 8.9 to 91 kPa, mimicking the range found on ex vivo analysis of 4.6-236.7 kPa. The urological surgeons determined the upper limit of stiffness palpated as realistic for a healthy prostate was 59.63 kPa while the lower limit of stiffness was 27.1 kPa. Nodule size less than 7.5mm was felt to be too small to reasonably palpate. CONCLUSIONS: We found it is not the absolute elasticity of the nodule, but rather the relationship of the nodule with the background prostate elasticity that constitutes the critical tactile feedback. Prostate simulator training may lead to greater familiarity with pertinent diagnostic cues and diagnosis of prostate cancer.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 50 条
  • [41] Fidelity and validity of simulator training
    Dahlstrom, N.
    Dekker, S.
    van Winsen, R.
    Nyce, J.
    THEORETICAL ISSUES IN ERGONOMICS SCIENCE, 2009, 10 (04) : 305 - 314
  • [42] Development of a high-fidelity minimally invasive mitral valve surgery simulator
    Nia, Peyman Sardari
    Daemen, Jean H. T.
    Maessen, Jos G.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (04): : 1567 - 1574
  • [43] A comparison of paediatric airway anatomy with the SimBaby high-fidelity patient simulator
    Schebesta, Karl
    Huepfl, Michael
    Ringl, Helmut
    Machata, Anette-Marie
    Chiari, Astrid
    Kimberger, Oliver
    RESUSCITATION, 2011, 82 (04) : 468 - 472
  • [44] Evaluating operator harvest technology within a high-fidelity combine simulator
    Meusel, Chase
    Kieu, Don
    Gilbert, Stephen
    Luecke, Greg
    Gilmore, Brian
    Kelly, Norene
    Hunt, Tim
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2018, 148 : 309 - 321
  • [45] Comparison of driver braking responses in a high-fidelity simulator and an a test track
    Hoffman, JD
    Lee, JD
    Brown, TL
    McGehee, DV
    HUMAN PERFORMANCE: MODELS, INTELLIGENT VEHICLE INITIATIVE, TRAVELER ADVISORY AND INFORMATION SYSTEMS: SAFETY AND HUMAN PERFORMANCE, 2002, (1803): : 59 - 65
  • [46] Innovative Left Ventricular Assist Device in High-fidelity Patient Simulator
    Lindsay, Wayne
    Nelms, Tiffany
    O'Hara, Sean
    Sletten, Zachary
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (04)
  • [47] Integration of high-fidelity simulator in third-year paediatrics clerkship
    Ortiz, Nerian
    Pedrogo, Yasmin
    Bonet, Nydia
    CLINICAL TEACHER, 2011, 8 (02): : 105 - 108
  • [48] High-Fidelity Autonomous Surface Vehicle Simulator for the Maritime RobotX Challenge
    Smith, Peter
    Dunbabin, Matthew
    IEEE JOURNAL OF OCEANIC ENGINEERING, 2019, 44 (02) : 310 - 319
  • [49] Prognostic Modeling Utilizing a High-Fidelity Pressurized Water Reactor Simulator
    McGhee, Mark J.
    Catterson, Victoria M.
    Brown, Blair
    IEEE TRANSACTIONS ON SYSTEMS MAN CYBERNETICS-SYSTEMS, 2018, 48 (05): : 727 - 732
  • [50] A high-fidelity dynamic simulator as a life-cycle design tool
    Graeser, HJ
    Marcev, CL
    Ito, N
    Waite, AWR
    Bialkowski, WL
    CONTROL SYSTEMS '96, PREPRINTS, 1996, : 195 - 200