Mean age of air in a naturally ventilated office: Experimental data and simulations

被引:70
|
作者
Buratti, C. [1 ]
Mariani, R. [1 ]
Moretti, E. [1 ]
机构
[1] Univ Perugia, Dept Ind Engn, I-06125 Perugia, Italy
关键词
Indoor air quality; Natural ventilation; Mean age of air; Decay method; Gas chromatography; CFD model; QUALITY;
D O I
10.1016/j.enbuild.2011.04.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air quality has an important role as health determinant: it relates to the health and comfort of building occupants. The present paper investigates the wind-forced natural ventilation rates of an office as observed with tracer decay, according to ISO 16000-8:2007 Standard, both with an experimental and numerical procedure: experimental data were used to validate the numerical method. Moreover the only infiltration rate case was analyzed. Natural ventilation was created by opening the window and the door of the office. A simulation model of the room was carried out by using the computational fluid dynamics (CFD) code Fluent. The experimental set up of the procedure was developed by a portable gas chromatograph. In both the numerical and experimental approach the mean age of air linking to ventilation efficiency was calculated. The defined experimental procedure can be applied to different situations, in order to evaluate the efficiency of both natural and forced ventilation existing systems. When the ventilation is clue to the opening of the window and the door, the simulation results are in a good agreement with the experimental ones, therefore the model could be applied to different situations, in order to reduce costs and time in the evaluation of indoor air quality. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2021 / 2027
页数:7
相关论文
共 50 条
  • [1] The impact of temperature on mean local air age and thermal comfort in a stratum ventilated office
    Tian, Lin
    Lin, Zhang
    Liu, Jing
    Yao, Ting
    Wang, Qiuwang
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (02) : 501 - 510
  • [2] A Thermal Comfort Levels Investigation of a Naturally Ventilated and Air-Conditioned Office
    Daghigh, R.
    Adam, N. M.
    Sopian, K.
    Zaharim, A.
    Sahari, B. B.
    [J]. SMO 08: PROCEEDINGS OF THE 8TH WSEAS INTERNATIONAL CONFERENCE ON SIMULATION, MODELLING AND OPTIMIZATION, 2008, : 189 - +
  • [3] Comparison of Indoor Air Quality for Air-Conditioned and Naturally Ventilated Office Spaces in Urban Area
    Jain, Supreme
    Garg, Divyam
    Goel, Anubha
    [J]. INDOOR ENVIRONMENTAL QUALITY, ACIEQ, 2020, 60 : 1 - 8
  • [4] Influences of Air Exchange Effectiveness and its Rate on Thermal Comfort: Naturally Ventilated Office
    Daghigh, R.
    Adam, N. M.
    Sahari, B. B.
    Sopian, K.
    Alghoul, M. A.
    [J]. JOURNAL OF BUILDING PHYSICS, 2008, 32 (02) : 175 - 194
  • [5] Indoor air quality and prevalence of asthma in office workers of a naturally ventilated antique building
    Rios, J.
    Boechat, J.
    Gottens, A.
    Ramos, C.
    Aquino, Neto F.
    Lapa e Silva, J.
    [J]. ALLERGY, 2008, 63 : 552 - 552
  • [6] Long-term monitoring data from a naturally ventilated office building
    Schweiker, Marcel
    Kleber, Michael
    Wagner, Andreas
    [J]. SCIENTIFIC DATA, 2019, 6 (1)
  • [7] Long-term monitoring data from a naturally ventilated office building
    Marcel Schweiker
    Michael Kleber
    Andreas Wagner
    [J]. Scientific Data, 6
  • [8] Assessing the performance of a naturally ventilated office building
    Walker, Christine E.
    Norford, Leslie K.
    Glicksman, Leon R.
    [J]. ASHRAE TRANSACTIONS 2006, VOL 112, PT 1, 2006, 112 : 281 - +
  • [9] Thermal comfort study of naturally ventilated office
    Laska, Marta
    [J]. 9TH CONFERENCE ON INTERDISCIPLINARY PROBLEMS IN ENVIRONMENTAL PROTECTION AND ENGINEERING (EKO-DOK 2017), 2017, 17
  • [10] Air velocities in a naturally ventilated greenhouse
    Teitel, M.
    Liran, O.
    Barak, M.
    Tanny, J.
    [J]. PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON GREENHOUSE COOLING, 2006, (719): : 189 - +