EXPERIMENTAL AND NUMERICAL ANALYSIS OF FLUID FLOW THROUGH A MICROMIXER WITH THE PRESENCE OF ELECTRIC FIELD

被引:0
|
作者
Rubby, Md Fazlay [1 ]
Parvez, Mohammad Salman [1 ]
Biswas, Prosanto [1 ]
Huq, Hasina [1 ]
Islam, Nazmul [1 ]
机构
[1] Univ Texas Rio Grande Valley, Dept Elect Engn, Rio Grande Valley, TX 78539 USA
关键词
Micromixer; Micro-PIV; AC Electroosmosis; Laminar flow; Sputtering;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Fluid flows in a microchannel with highly ordered laminar fashion. For this reason, two different fluid streams cannot mix easily, or it takes a very long time. The problem becomes intense for large molecules such as peptides, proteins, and nucleic acids during rapid mixing for biochemical applications in a microfluidic device. Many researchers tried to solve this problem by applying an elecfric potential. In this work, a numerical simulation was performed on a 2D micromixer. Four symmetric electrodes were placed on the wall of a straight microchannel of width 19 mu m. The electroosmotic slip velocity boundary condition was used to create the turbulence on the laminar fluid stream. It was found that this model creates a well-mixed flow at the channel outlet. Then the input parameters were changed to compare the mixing performance in terms of concentration distribution at the channel outlet. Channel width, interelectrodes gap, the magnitude of electric potential, frequency of the electric potential and asymmetricity of the electrodes were changed and results were compared. An experimental micromixer like the numerical model was fabricated by dc magnetron sputtering machine. Four gold electrodes (thickness, 120 nm) were sputtered on top of a silicon substrate. The value of the input parameters was chosen based on the results obtained from the numerical simulation. To test the mixing functionality of our device the movement of tracer particles was tracked down on the zone surrounded by four electrodes. The micro-PIV (Particulate Image Velocimetry) system was used to analyze the movement of the tracer particles and visualize the flow field in the mixing zone. The magnitude of the AC electric potential and frequency was changed to find out the optimum input parameters for the micromixer. These results could play an important role to design and improve a micromixer design using an AC electric field. A micromixer has many potential applications in biology (DNA analysis, enzyme Screening), chemistry (synthesis, polymerization) and detection (drug discovery, diagnosis).
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Numerical analysis of an MHD flow in fuzzy environment in presence of induced magnetic field
    Hazarika, Gopal Chandra
    Dutta, Palash
    Borah, Joydeep
    HEAT TRANSFER, 2021, 50 (06) : 6099 - 6109
  • [42] Numerical analysis on the flow of molten steel in the casting cavity in the presence of magnetic field
    Singh, Ranjit J.
    Gohil, Trushar B.
    MATERIALS TODAY-PROCEEDINGS, 2021, 44 : 356 - 361
  • [43] Numerical modeling and experimental optimization of Taylor dispersion analysis with and without an electric field
    Chenyakin, Yuri
    Chen, David Da Yong
    ELECTROPHORESIS, 2024, 45 (11-12) : 1054 - 1064
  • [44] Experimental and CFD analysis of fluid flow through nanofiber filter media
    Azimian, Mehdi
    Naderi, Matin
    Soltani, Parham
    Cheng, Liping
    Naderi, Keivan
    Linden, Sven
    Wiegmann, Andreas
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [45] Experimental and numerical analysis of a three-dimensional flow field for PEMFCs
    Li, Wenkai
    Zhang, Qinglei
    Wang, Chao
    Yan, Xiaohui
    Shen, Shuiyun
    Xia, Guofeng
    Zhu, Fengjuan
    Zhang, Junliang
    APPLIED ENERGY, 2017, 195 : 278 - 288
  • [46] Numerical and experimental analysis of the flow field around a surface combatant ship
    Zaghi, S.
    Broglia, R.
    Guadalupi, D.
    SUSTAINABLE MARITIME TRANSPORTATION AND EXPLOITATION OF SEA RESOURCES, VOL 1, 2012, : 87 - 94
  • [47] Experimental and numerical analysis of fluid-solid-thermal coupling on electric fuel pump
    Wei, Renfeng
    Ye, Zhifeng
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2021, 235 (11) : 1427 - 1440
  • [48] NUMERICAL-ANALYSIS OF ELECTRIC-FIELD IN A CLOSED SPACE INJECTED WITH CHARGED FLUID
    YAMANE, K
    YOSHIDA, K
    AYA, I
    JOURNAL OF ELECTROSTATICS, 1994, 33 (01) : 43 - 59
  • [49] Numerical analysis of fluid flow through radial diffusers in the presence of a chamfer in the feeding orifice with a mixed Eulerian-Lagrangian method
    Mariani, Viviana Cocco
    Prata, Alvaro Toubes
    Deschamps, Cesar Jose
    COMPUTERS & FLUIDS, 2010, 39 (09) : 1672 - 1684
  • [50] Performance optimization of microreactors by implementing geometrical and fluid flow control in the presence of electric field: a computational study
    Amir Shamloo
    Fatemeh Sharifi
    Seyede Sara Salehi
    Leila Amirifar
    Bahar Firoozabadi
    Microsystem Technologies, 2015, 21 : 1275 - 1285