摘要
Fluid flows in a microchannel with highly ordered laminar fashion. For this reason, two different fluid streams cannot mix easily, or it takes a very long time. The problem becomes intense for large molecules such as peptides, proteins, and nucleic acids during rapid mixing for biochemical applications in a microfluidic device. Many researchers tried to solve this problem by applying an elecfric potential. In this work, a numerical simulation was performed on a 2D micromixer. Four symmetric electrodes were placed on the wall of a straight microchannel of width 19 mu m. The electroosmotic slip velocity boundary condition was used to create the turbulence on the laminar fluid stream. It was found that this model creates a well-mixed flow at the channel outlet. Then the input parameters were changed to compare the mixing performance in terms of concentration distribution at the channel outlet. Channel width, interelectrodes gap, the magnitude of electric potential, frequency of the electric potential and asymmetricity of the electrodes were changed and results were compared. An experimental micromixer like the numerical model was fabricated by dc magnetron sputtering machine. Four gold electrodes (thickness, 120 nm) were sputtered on top of a silicon substrate. The value of the input parameters was chosen based on the results obtained from the numerical simulation. To test the mixing functionality of our device the movement of tracer particles was tracked down on the zone surrounded by four electrodes. The micro-PIV (Particulate Image Velocimetry) system was used to analyze the movement of the tracer particles and visualize the flow field in the mixing zone. The magnitude of the AC electric potential and frequency was changed to find out the optimum input parameters for the micromixer. These results could play an important role to design and improve a micromixer design using an AC electric field. A micromixer has many potential applications in biology (DNA analysis, enzyme Screening), chemistry (synthesis, polymerization) and detection (drug discovery, diagnosis).
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Flow Field Analysis of Micromixer Powered by Ciliary Motion of Vorticella
    Hayasaka, Yo
    Nagai, Moeto
    Matsumoto, Nobuyoshi
    Kawashima, Takahiro
    Shibata, Takayuki
    [J]. ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2013, 96 (10) : 43 - 49
  • [22] Magnetohydrodynamic micropolar fluid flow in presence of nanoparticles through porous plate: A numerical study
    Arifuzzaman, S. M.
    Mehedi, Md Farid Uddin
    Al-Mamun, Abdullah
    Biswas, Pronab
    Islam, Md Rafiqul
    Khan, Md Shakhaoath
    [J]. INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2018, 36 (03) : 947 - 959
  • [23] Numerical and experimental analysis of fluid-fluid interaction and flow through micro clearance to estimate leakages in a fuel injection pump
    Kamaraj, Balasakthivel
    Subramanian, Shankar C.
    Rakkiappan, Baskaran
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2017, 231 (11) : 2054 - 2065
  • [24] NUMERICAL AND EXPERIMENTAL RESULTS ON DISPERSION OF A SOLUTE IN A FLUID IN LAMINAR FLOW THROUGH A TUBE
    BAILEY, HR
    GOGARTY, WB
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1962, 269 (1338): : 352 - &
  • [25] Intermittent granular flow in the presence of an electric field
    Chen, W
    Hou, M
    Jiang, Z
    Lu, K
    Lam, L
    [J]. EUROPHYSICS LETTERS, 2001, 56 (04): : 536 - 541
  • [26] Numerical and Experimental Analysis of the Fluid-Structure Interaction in Presence of a Hyperelastic Body
    Esmailzadeh, H.
    Passandideh-Fard, M.
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (11):
  • [27] NUMERICAL ANALYSIS OF DIELECTRIC MICRO-PARTICLE MOTION IN A FLUID AND ELECTRIC FIELD
    Baek, Myung Ki
    Kim, Young Sun
    Park, Il Han
    [J]. COMPUTATIONAL METHODS FOR COUPLED PROBLEMS IN SCIENCE AND ENGINEERING IV, 2011, : 398 - 403
  • [28] Experimental analysis of frost formation with the presence of an electric field on fin and tube evaporator
    Joppolo, Cesare Maria
    Molinaroli, Luca
    De Antonellis, Stefano
    Merlo, Umberto
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (02): : 468 - 474
  • [29] Peristaltic flow of a micropolar fluid through a porous medium in the presence of an external magnetic field
    Pandey, S. K.
    Chaube, M. K.
    [J]. COMMUNICATIONS IN NONLINEAR SCIENCE AND NUMERICAL SIMULATION, 2011, 16 (09) : 3591 - 3601
  • [30] Numerical and experimental analyses of planar micromixer with gaps and baffles based on field synergy principle
    Xia, G. D.
    Li, Y. F.
    Wang, J.
    Zhai, Y. L.
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2016, 71 : 188 - 196