EXPERIMENTAL AND NUMERICAL ANALYSIS OF FLUID FLOW THROUGH A MICROMIXER WITH THE PRESENCE OF ELECTRIC FIELD

被引:0
|
作者
Rubby, Md Fazlay [1 ]
Parvez, Mohammad Salman [1 ]
Biswas, Prosanto [1 ]
Huq, Hasina [1 ]
Islam, Nazmul [1 ]
机构
[1] Univ Texas Rio Grande Valley, Dept Elect Engn, Rio Grande Valley, TX 78539 USA
关键词
Micromixer; Micro-PIV; AC Electroosmosis; Laminar flow; Sputtering;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Fluid flows in a microchannel with highly ordered laminar fashion. For this reason, two different fluid streams cannot mix easily, or it takes a very long time. The problem becomes intense for large molecules such as peptides, proteins, and nucleic acids during rapid mixing for biochemical applications in a microfluidic device. Many researchers tried to solve this problem by applying an elecfric potential. In this work, a numerical simulation was performed on a 2D micromixer. Four symmetric electrodes were placed on the wall of a straight microchannel of width 19 mu m. The electroosmotic slip velocity boundary condition was used to create the turbulence on the laminar fluid stream. It was found that this model creates a well-mixed flow at the channel outlet. Then the input parameters were changed to compare the mixing performance in terms of concentration distribution at the channel outlet. Channel width, interelectrodes gap, the magnitude of electric potential, frequency of the electric potential and asymmetricity of the electrodes were changed and results were compared. An experimental micromixer like the numerical model was fabricated by dc magnetron sputtering machine. Four gold electrodes (thickness, 120 nm) were sputtered on top of a silicon substrate. The value of the input parameters was chosen based on the results obtained from the numerical simulation. To test the mixing functionality of our device the movement of tracer particles was tracked down on the zone surrounded by four electrodes. The micro-PIV (Particulate Image Velocimetry) system was used to analyze the movement of the tracer particles and visualize the flow field in the mixing zone. The magnitude of the AC electric potential and frequency was changed to find out the optimum input parameters for the micromixer. These results could play an important role to design and improve a micromixer design using an AC electric field. A micromixer has many potential applications in biology (DNA analysis, enzyme Screening), chemistry (synthesis, polymerization) and detection (drug discovery, diagnosis).
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Peristaltic flow of a micropolar fluid through a porous medium in the presence of an external magnetic field
    Pandey, S. K.
    Chaube, M. K.
    COMMUNICATIONS IN NONLINEAR SCIENCE AND NUMERICAL SIMULATION, 2011, 16 (09) : 3591 - 3601
  • [32] Experimental analysis of frost formation with the presence of an electric field on fin and tube evaporator
    Joppolo, Cesare Maria
    Molinaroli, Luca
    De Antonellis, Stefano
    Merlo, Umberto
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (02): : 468 - 474
  • [33] Numerical and experimental mixing studies in a MEMS-based multilaminated/elongational flow micromixer
    Adeosun, John T.
    Lawal, Adeniyi
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (02): : 637 - 647
  • [34] Flow field analysis of a passive wavy micromixer with CSAR and ESAR elements
    Ranjitsinha R. Gidde
    Prashant M. Pawar
    Babruvahan P. Ronge
    Anil B. Shinde
    Nitin D. Misal
    Sandeep S. Wangikar
    Microsystem Technologies, 2019, 25 : 1017 - 1030
  • [35] Determining Human Presence through the Analysis of the Electric Field using MATLAB environment
    Hoarca, Ioan Cristian
    PROCEEDINGS OF THE 2020 12TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTERS AND ARTIFICIAL INTELLIGENCE (ECAI-2020), 2020,
  • [36] Flow field analysis of a passive wavy micromixer with CSAR and ESAR elements
    Gidde, Ranjitsinha R.
    Pawar, Prashant M.
    Ronge, Babruvahan P.
    Shinde, Anil B.
    Misal, Nitin D.
    Wangikar, Sandeep S.
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2019, 25 (03): : 1017 - 1030
  • [37] Experimental and numerical flow field investigation through two types of radial flow compressor volutes
    Mojaddam, Mohammad
    Hajilouy-Benisi, Ali
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2016, 78 : 137 - 146
  • [38] Numerical and experimental study on the synergistic effect of vortex and contact surface of fluid in the inlet section of micromixer
    Qin, Litao
    Yue, Jincai
    Zhou, Dongjian
    Yang, Anming
    Zheng, Shiqing
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2024, 196
  • [39] Fluid Flow through Natural Single-Rock Fractures: Experimental and Numerical Investigations
    Kulatilake, Pinnaduwa H. S. W.
    Park, Jinyong
    Su, Xiao-peng
    INTERNATIONAL JOURNAL OF GEOMECHANICS, 2020, 20 (10)
  • [40] Numerical Analysis of the Flow Field in a Y-Type Micromixer Using Moving Particle Semi-Implicit Method
    Wang F.
    Sun Z.
    Liu Q.
    Zhang K.
    Xi G.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2021, 55 (05): : 162 - 170