A dynamic model of supercritical boiler-turbine unit based on immune genetic algorithm parameter identification

被引:0
|
作者
Hau, Guolian [1 ]
Tang, Zhiyan [1 ]
Gong, Linjuan [1 ]
Su, Huilin [1 ]
Hu, Bo [2 ]
Zhao, Yuanzhu [2 ]
机构
[1] North China Elect Power Univ, Sch Control & Comp Engn, Beijing 102206, Peoples R China
[2] State Grid Liaoning Elect Power Supply Co Ltd, Shenyang 110004, Peoples R China
关键词
Supercritical once-through boiler-turbine unit; Immune genetic algorithm (IGA); Mathematical model; Parameter identification; ONCE-THROUGH BOILER; SYSTEM;
D O I
10.1109/CCDC52312.2021.9601729
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In recent years, with the development of coal-fired units towards large capacity and high parameters, the position of supercritical once-through boiler unit has become more prominent. In this paper, a nonlinear mathematical model of the supercritical boiler unit is established through a series of assumptions and formula derivation, and then the parameters are identified through regression analysis and immune genetic algorithm (IGA) combined with the operation data of a 1000MW supercritical unit. The inputs of the model are fuel command, feed water and turbine governor valve position while the outputs are turbine power, main steam pressure and steam enthalpy at separator outlet. The simulation results show that the model can characterize the dynamic characteristics of the unit and has acceptable accuracy.
引用
收藏
页码:6185 / 6190
页数:6
相关论文
共 50 条
  • [21] Optimization of PID controllers of a boiler-turbine coordinated control system based on a genetic algorithm
    Xue, Ya-Li
    Li, Dong-Hai
    Lu, Chong-De
    Reneng Dongli Gongcheng/Journal of Engineering for Thermal Energy and Power, 2006, 21 (01): : 80 - 83
  • [22] Boiler-turbine control based multi-model and dynamic decouple PID
    Chen, YQ
    Liu, JZ
    Niu, YG
    Ni, M
    PROCEEDINGS OF THE 2005 INTERNATIONAL CONFERENCE ON NEURAL NETWORKS AND BRAIN, VOLS 1-3, 2005, : 1791 - 1794
  • [23] A dynamic hybrid model of supercritical once-through boiler-turbine unit including recirculation mode and once-through mode
    Xie, Yan
    Liu, Ji-zhen
    Zeng, De-liang
    Hu, Yong
    Li, Rui-lian
    Zhu, Yan-song
    ENERGY, 2024, 309
  • [24] Design and Implementation of a Multiple-Model based Control scheme for Boiler-Turbine Unit
    Arasu, S. Kapil
    Prakash, J.
    IFAC PAPERSONLINE, 2015, 48 (08): : 495 - 500
  • [25] Modeling of Drum Boiler-Turbine Unit and the Model-based Coordinated Control Strategy
    Tian, Zhen
    Yuan, Jingqi
    Xu, Liang
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 3327 - 3332
  • [26] Optimal partitioning of a boiler-turbine unit for Fuzzy model predictive control
    Killian, M.
    Kozek, M.
    IFAC PAPERSONLINE, 2017, 50 (01): : 2011 - 2016
  • [27] Disturbance Rejection Model Predictive Control of Ultra-Supercritical Once-Through Boiler-Turbine Unit
    Zhang, Fan
    Xue, Yali
    Li, Donghai
    Shen, Jiong
    2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 3582 - 3587
  • [28] A dynamic model used for controller design of a coal fired once-through boiler-turbine unit
    Liu, Ji-Zhen
    Yan, Shu
    Zeng, De-Liang
    Hu, Yong
    Lv, You
    ENERGY, 2015, 93 : 2069 - 2078
  • [29] The boiler-turbine coordinated control system based on immune feedback mechanism
    Peng, Dao-Gang
    Mang, Hao
    Yang, Ping
    PROCEEDINGS OF 2007 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOLS 1-7, 2007, : 449 - 453
  • [30] REALIZATION OF A LINEAR MATHEMATICAL-MODEL OF A BOILER-TURBINE GENERATING UNIT ON COMPUTERS
    SMIRNOV, VN
    THERMAL ENGINEERING, 1974, 21 (08) : 48 - 52