Sensitivity Enhancement for Low-Coherence Interferometry

被引:3
|
作者
Benitez, J. [1 ]
Mora, J. [1 ]
机构
[1] Univ Politecn Valencia, ITEAM Res Inst, E-46022 Valencia, Spain
关键词
Low coherence interferometry; microwave photonics; optical profile; phase modulation; sensitivity; TOMOGRAPHY; MODULATION;
D O I
10.1109/LPT.2017.2748818
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this letter, a sensitivity improvement for systems combining low-coherence interferometry (LCI) and microwave photonics (MWP) is demonstrated. This improvement is due to the introduction of a different modulation format and an exhaustive control of the optical source profile compared with previous MWP-LCI schemes. Our proposal allows to retrieve the visibility of low-coherence interferograms through the analysis of the interference pattern using a dispersive element. We demonstrate that the use of a phase modulator offers better stability and lower insertion loss since a bias point configuration is not needed compared with the intensity modulators typically used in these schemes. The process for controlling the optical source profile permits a comparison between uniform and Gaussian profiles. In this way, the limiting effects of the sidelobes over the achieved sensitivity level are analyzed. The proposed MWP-LCI structure is experimentally demonstrated through the characterization of the electrical transfer function. In this case, a maximum sensitivity of 65 dB is achieved in our MWP-LCI structure showing a 30-dB improvement compared with current proposals.
引用
收藏
页码:1735 / 1738
页数:4
相关论文
共 50 条
  • [41] Polarized low-coherence interferometry applied to birefringent fiber characterization
    Gaillard, Virginie
    Leduc, Dominique
    Lupi, Cyril
    Boisrobert, Christian
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (03)
  • [42] Differential low-coherence interferometry for in situ diagnostics of transparent structures
    V. V. Ivanov
    V. A. Markelov
    M. A. Novikov
    S. S. Ustavshchikov
    [J]. Technical Physics Letters, 2004, 30 : 389 - 391
  • [43] Noise characterization of supercontinuum sources for low-coherence interferometry applications
    Brown, William J.
    Kim, Sanghoon
    Wax, Adam
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2014, 31 (12) : 2703 - 2710
  • [44] Air refractive index measurement using low-coherence interferometry
    Pikalek, Tomas
    Buchta, Zdenek
    [J]. APPLIED OPTICS, 2015, 54 (16) : 5024 - 5030
  • [45] In vivo imaging and low-coherence interferometry of organ of Corti vibration
    Chen, Fangyi
    Choudhury, Niloy
    Zheng, Jiefu
    Matthews, Scott
    Nutall, Alfred L.
    Jacques, Steven L.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (02)
  • [46] Comparison of an optical low-coherence interferometry and a Scheimpflug imaging combined with partial coherence interferometry biometers in cataract patients
    Han, Eui S.
    Kim, Moonjung
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 47 : 85 - 85
  • [47] Measurement of dye diffusion in agar gel by use of low-coherence interferometry
    Storen, T
    Simonsen, A
    Lokberg, OJ
    Lindmo, T
    Svaasand, LO
    Royset, A
    [J]. OPTICS LETTERS, 2003, 28 (14) : 1215 - 1217
  • [48] Direct velocity sensing of flow distribution based on low-coherence interferometry
    Imai, Y
    Tanaka, K
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (08): : 2007 - 2012
  • [49] Investigation of tribology phenomena by low-coherence fiber-optic interferometry
    Djinovic, Z
    Mitic, S
    Tomic, M
    Cordes, M
    Vujanic, A
    Kment, C
    [J]. 2004 24TH INTERNATIONAL CONFERENCE ON MICROELECTRONICS, PROCEEDINGS, VOLS 1 AND 2, 2004, : 227 - 230
  • [50] Fiber-optic temperature sensor using low-coherence interferometry
    Jedrzejewska-Szczerska, M.
    Bogdanowicz, R.
    Gnyba, M.
    Hypszer, R.
    Kosmowski, B. B.
    [J]. EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2008, 154 (1): : 107 - 111