The influence of the connection, length and diameter of an implant on bone biomechanics

被引:15
|
作者
Borie, Eduardo [1 ,2 ]
Orsi, Iara Augusta [2 ]
de Araujo, Carlos P. R. [3 ]
机构
[1] Univ La Frontera, Sch Dent, CIMOFIR Res Ctr, Temuco 4781176, Chile
[2] Univ Sao Paulo, Ribeirao Preto Dent Sch, Dent Mat & Prosthodont Dept, Ribeirao Preto, SP, Brazil
[3] Univ Sao Paulo, Sch Dent Bauru, Dept Prosthodont, Bauru, SP, Brazil
关键词
biomechanics; bone; dental implants; implant connection; FINITE-ELEMENT-ANALYSIS; INTERNAL CONICAL INTERFACE; FIXED PARTIAL PROSTHESES; STRESS-DISTRIBUTION; OSSEOINTEGRATED IMPLANTS; ABUTMENT INTERFACE; EXTERNAL-HEXAGON; IN-VITRO; DENTAL IMPLANTS; PHOTOELASTIC ANALYSIS;
D O I
10.3109/00016357.2014.961957
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background. Regardless of the multiple options of connections, diameters and heights for dental implants, the clinician should know the biomechanical behavior of the bone to plan the treatment according to the biological and anatomical conditions of each patient, without risk to the long-term treatment success. Review. The following review attempts to summarize the relevant literature to establish guidelines for clinicians based on the scientific evidence regarding the influence by the implant's connection, diameter and length on the bone biomechanics. Conclusions. The length, diameter and connection of each implant have a degree of influence in bone biomechanics. Despite the influence of different implant connections, diameters and lengths on peri-implant bone stress and strain, these characteristics should remain within the physiological limits to avoid a pathological overload, bone resorption and consequent risk to the long-term success of implant-prosthetic treatment.
引用
收藏
页码:321 / 329
页数:9
相关论文
共 50 条
  • [41] The influence of implant-abutment connection to peri-implant bone loss: A systematic review and meta-analysis
    Caricasulo, Riccardo
    Malchiodi, Luciano
    Ghensi, Paolo
    Fantozzi, Giuliano
    Cucchi, Alessandro
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (04) : 653 - 664
  • [42] Influence of a new abutment design concept on the biomechanics of peri-implant bone, implant components, and microgap formation: a finite element analysis
    Huimin Nie
    Yantai Tang
    Yan Yang
    Weijie Wu
    Wenjuan Zhou
    Zhonghao Liu
    BMC Oral Health, 23
  • [43] Influence of a new abutment design concept on the biomechanics of peri-implant bone, implant components, and microgap formation: a finite element analysis
    Nie, Huimin
    Tang, Yantai
    Yang, Yan
    Wu, Weijie
    Zhou, Wenjuan
    Liu, Zhonghao
    BMC ORAL HEALTH, 2023, 23 (01)
  • [44] Combined Influence of Implant Diameter and Alveolar Ridge Width on Crestal Bone Stress: A Quantitative Approach
    Yu, Wonjae
    Jang, Yoon-Je
    Kyung, Hee-Moon
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (01) : 88 - 95
  • [45] Minimization of dental implant diameter and length according to bone quality determined by finite element analysis and optimized calculation
    Ueda, Nana
    Takayama, Yoshiyuki
    Yokoyama, Atsuro
    JOURNAL OF PROSTHODONTIC RESEARCH, 2017, 61 (03) : 324 - 332
  • [46] The effect of dental implant length and diameter to implant mobility measured using IM checker
    Wijaya, SK
    Oka, H
    Sumikawa, T
    Saratani, K
    Kawazoe, T
    IEEE EMBS APBME 2003, 2003, : 262 - 263
  • [47] Influence of Diameter of FGM Implant on Stress Distribution
    Elleuch, Sameh
    Jrad, Hanen
    Wali, Mondher
    Dammak, Fakhreddine
    Lecture Notes in Mechanical Engineering, 2022, : 49 - 55
  • [48] Influence of bone insertion level of the implant on the fracture strength of different connection designs: an in vitro study
    Gehrke, Sergio Alexandre
    dos Santos Vianna, Miriam Souza
    Dedavid, Berenice Anina
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (03) : 715 - 720
  • [49] Influence of bone insertion level of the implant on the fracture strength of different connection designs: an in vitro study
    Sergio Alexandre Gehrke
    Miriam Souza dos Santos Vianna
    Berenice Anina Dedavid
    Clinical Oral Investigations, 2014, 18 : 715 - 720
  • [50] Influence of Implant-Abutment Connection Biomechanics on Biological Response: A Literature Review on Interfaces between Implants and Abutments of Titanium and Zirconia
    Choi, Sunyoung
    Kang, Young Suk
    Yeo, In-Sung Luke
    PROSTHESIS, 2023, 5 (02): : 527 - 538