Influence of Implant-Abutment Connection Biomechanics on Biological Response: A Literature Review on Interfaces between Implants and Abutments of Titanium and Zirconia

被引:18
|
作者
Choi, Sunyoung [1 ]
Kang, Young Suk [2 ]
Yeo, In-Sung Luke [3 ,4 ]
机构
[1] Seoul Natl Univ, One Stop Specialty Ctr, Dept Prosthodont, Dent Hosp, Seoul 03080, South Korea
[2] 618th Med Co, Dent Area Support, Dent Hlth Act Korea, APO, AP 96297 USA
[3] Seoul Natl Univ, Sch Dent, Dept Prosthodont, Seoul 03080, South Korea
[4] Seoul Natl Univ, Dent Res Inst, Seoul 03080, South Korea
来源
PROSTHESIS | 2023年 / 5卷 / 02期
基金
新加坡国家研究基金会;
关键词
dental abutments; dental implant-abutment connection; dental implants; zirconium oxide; HARD-TISSUE RESPONSE; CRESTAL BONE CHANGES; DENTAL IMPLANTS; HISTOMETRIC EVALUATION; STABILIZED ZIRCONIA; SUBMERGED IMPLANTS; IMMEDIATE OCCLUSAL; ORAL IMPLANTS; SURVIVAL; COMPLICATIONS;
D O I
10.3390/prosthesis5020036
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The interface between a dental implant and an abutment is stabilized by two mechanical characteristics: a preload of an abutment screw and the friction between the contact surfaces of the implant and the abutment. These mechanical properties are quantitatively analyzed by using physical and mechanical formulas. The important thing is that such mechanical properties cause various biological phenomena when medical devices are inserted into human bodies. Some mechanical complications in dental implant prostheses are closely associated with biological complications. This literature review explores the mechanical complications of the implant-abutment connection and their biological effects in a titanium dental implant system, which is the system most widely used in dental clinics. Understanding the biomechanics of the implant-abutment connection helps to predict the merits and limits of zirconia dental implants, which have been recently introduced and clinically applied.
引用
收藏
页码:527 / 538
页数:12
相关论文
共 33 条
  • [1] Mechanical behavior of titanium and zirconia abutments at the implant-abutment interface: A systematic review
    Pereira, Anne Karoline de Holanda Cavalcanti
    Limirio, Joao Pedro Justino de Oliveira
    Vasconcelos, Belmiro Cavalcanti do Egito
    Pellizzer, Eduardo Piza
    de Moraes, Sandra Lucia Dantas
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03): : 420 - 426
  • [2] Effect of Different Implant-Abutment Connection Materials on the Fracture Resistance of Zirconia Abutments
    AlAmar, Mohammed
    Alqahtani, Fawaz
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (02) : 88 - 92
  • [3] In Vitro Study of the Influence of the Type of Connection on the Fracture Load of Zirconia Abutments with Internal and External Implant-Abutment Connections
    Sailer, Irena
    Sailer, Thomas
    Stawarczyk, Bogna
    Jung, Ronald Ernst
    Haemmerle, Christoph Hans Franz
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 850 - 858
  • [4] A systematic review of the influence of the implant-abutment connection on the clinical outcomes of ceramic and metal implant abutments supporting fixed implant reconstructions
    Pjetursson, Bjarni Elvar
    Zarauz, Cristina
    Strasding, Malin
    Sailer, Irena
    Zwahlen, Marcel
    Zembic, Anja
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 160 - 183
  • [5] Comparisons of maximum deformation and failure forces at the implant-abutment interface of titanium implants between titanium-alloy and zirconia abutments with two levels of marginal bone loss
    Wang, Chiung-Fang
    Huang, Heng-Li
    Lin, Dan-Jae
    Shen, Yen-Wen
    Fuh, Lih-Jyh
    Hsu, Jui-Ting
    BIOMEDICAL ENGINEERING ONLINE, 2013, 12
  • [6] Bending Moments and Types of Failure of Zirconia and Titanium Abutments with Internal Implant-Abutment Connections: A Laboratory Study
    Leutert, Christian R.
    Stawarczyk, Bogna
    Truninger, Thomas C.
    Haemmerle, Christoph H. F.
    Sailer, Irena
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (03) : 505 - 512
  • [7] Bending moments of zirconia and titanium abutments with internal and external implant-abutment connections after aging and chewing simulation
    Truninger, Thomas C.
    Stawarczyk, Bogna
    Leutert, Christian R.
    Sailer, Thomas R.
    Haemmerle, Christoph H. F.
    Sailer, Irena
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (01) : 12 - 18
  • [8] Influence of different implant-abutment connection designs on the mechanical and biological behavior of single-tooth implants in the maxillary esthetic zone: A systematic review
    Vetromilla, Bruna M.
    Brondani, Lucas P.
    Pereira-Cenci, Tatiana
    Bergoli, Cesar D.
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (03): : 398 - +
  • [9] Influence of the Use of Transepithelial Abutments vs. Titanium Base Abutments on Microgap Formation at the Dental Implant-Abutment Interface: An In Vitro Study
    Cascos, Rocio
    Celemin-Vinuela, Alicia
    Mory-Rubinos, Nataly
    Gomez-Polo, Cristina
    Ortega, Rocio
    Agustin-Panadero, Ruben
    Gomez-Polo, Miguel
    MATERIALS, 2023, 16 (19)
  • [10] Evaluation of the influence of connection configuration on the implant-abutment interface vertical misfit of original milled titanium and laser-sintered cobalt-chromium abutments
    Diaz, Pedro
    Vizoso, Beatriz
    Lopez-Suarez, Carlos
    Gonzalo, Esther
    Mosaddad, Seyed Ali
    Suarez, Maria J.
    CLINICAL ORAL INVESTIGATIONS, 2025, 29 (01)