Influence of Implant-Abutment Connection Biomechanics on Biological Response: A Literature Review on Interfaces between Implants and Abutments of Titanium and Zirconia

被引:18
|
作者
Choi, Sunyoung [1 ]
Kang, Young Suk [2 ]
Yeo, In-Sung Luke [3 ,4 ]
机构
[1] Seoul Natl Univ, One Stop Specialty Ctr, Dept Prosthodont, Dent Hosp, Seoul 03080, South Korea
[2] 618th Med Co, Dent Area Support, Dent Hlth Act Korea, APO, AP 96297 USA
[3] Seoul Natl Univ, Sch Dent, Dept Prosthodont, Seoul 03080, South Korea
[4] Seoul Natl Univ, Dent Res Inst, Seoul 03080, South Korea
来源
PROSTHESIS | 2023年 / 5卷 / 02期
基金
新加坡国家研究基金会;
关键词
dental abutments; dental implant-abutment connection; dental implants; zirconium oxide; HARD-TISSUE RESPONSE; CRESTAL BONE CHANGES; DENTAL IMPLANTS; HISTOMETRIC EVALUATION; STABILIZED ZIRCONIA; SUBMERGED IMPLANTS; IMMEDIATE OCCLUSAL; ORAL IMPLANTS; SURVIVAL; COMPLICATIONS;
D O I
10.3390/prosthesis5020036
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The interface between a dental implant and an abutment is stabilized by two mechanical characteristics: a preload of an abutment screw and the friction between the contact surfaces of the implant and the abutment. These mechanical properties are quantitatively analyzed by using physical and mechanical formulas. The important thing is that such mechanical properties cause various biological phenomena when medical devices are inserted into human bodies. Some mechanical complications in dental implant prostheses are closely associated with biological complications. This literature review explores the mechanical complications of the implant-abutment connection and their biological effects in a titanium dental implant system, which is the system most widely used in dental clinics. Understanding the biomechanics of the implant-abutment connection helps to predict the merits and limits of zirconia dental implants, which have been recently introduced and clinically applied.
引用
收藏
页码:527 / 538
页数:12
相关论文
共 33 条
  • [21] Implant-abutment screw removal torque values between customized titanium abutment, straight titanium abutment, and hybrid zirconia abutment after a million cyclic loading: an in vitro comparative study
    Klongbunjit, Disayut
    Aunmeungtong, Weerapan
    Khongkhunthian, Pathawee
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [22] Implant-abutment screw removal torque values between customized titanium abutment, straight titanium abutment, and hybrid zirconia abutment after a million cyclic loading: an in vitro comparative study
    Disayut Klongbunjit
    Weerapan Aunmeungtong
    Pathawee Khongkhunthian
    International Journal of Implant Dentistry, 7
  • [23] Comparisons of maximum deformation and failure forces at the implant–abutment interface of titanium implants between titanium-alloy and zirconia abutments with two levels of marginal bone loss
    Chiung-Fang Wang
    Heng-Li Huang
    Dan-Jae Lin
    Yen-Wen Shen
    Lih-Jyh Fuh
    Jui-Ting Hsu
    BioMedical Engineering OnLine, 12
  • [24] Influence of eccentric cyclic loading on implant components: Comparison between titanium and zirconia abutments
    Nakano, Ryotaro
    Homma, Shinya
    Takanashi, Takuya
    Hirano, Tomoki
    Furuya, Yoshitaka
    Yajima, Yasutomo
    DENTAL MATERIALS JOURNAL, 2021, 40 (01) : 235 - 244
  • [25] Comparison between bone-implant interfaces of microtopographically modified zirconia and titanium implants
    Thu, Myint Kyaw
    Kang, Young Suk
    Kwak, Jeong Min
    Jo, Ye-Hyeon
    Han, Jung-Suk
    Yeo, In-Sung Luke
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [26] Pull-off Force of Four Different Implant Cements Between Zirconia Crowns and Titanium Implant Abutments in Two Different Abutment Heights
    Volkmann, Hanna
    Rauch, Angelika
    Koenig, Andreas
    Schierz, Oliver
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2022, 42 (03) : E67 - E74
  • [27] Influence of the implant-abutment connection on the ratio between height and thickness of tissues at the buccal zenith: a randomized controlled trial on 188 implants placed in 104 patients
    Farronato, Davide
    Pasini, Pietro Mario
    Manfredini, Mattia
    Scognamiglio, Cristian
    Orsina, Andrea Alain
    Farronato, Marco
    BMC ORAL HEALTH, 2020, 20 (01)
  • [28] Influence of the implant-abutment connection on the ratio between height and thickness of tissues at the buccal zenith: a randomized controlled trial on 188 implants placed in 104 patients
    Davide Farronato
    Pietro Mario Pasini
    Mattia Manfredini
    Cristian Scognamiglio
    Andrea Alain Orsina
    Marco Farronato
    BMC Oral Health, 20
  • [29] In Vitro Microbiological Bacterial Seal Analysis of the Implant/Abutment Connection in Morse Taper Implants: A Comparative Study Between 2 Abutments
    Deconto, Marco Antonio
    Salvoni, Alexander D'Alvia
    Wassall, Thomaz
    IMPLANT DENTISTRY, 2010, 19 (02) : 158 - 166
  • [30] Long-Term Survival and Peri-Implant Health of Titanium Implants with Zirconia Abutments: A Systematic Review and Meta-Analysis
    Cao, Yubin
    Yu, Changhao
    Wu, Yingyi
    Li, Longjiang
    Li, Chunjie
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (08): : 883 - 892