Influence of the implant-abutment connection on the ratio between height and thickness of tissues at the buccal zenith: a randomized controlled trial on 188 implants placed in 104 patients

被引:4
|
作者
Farronato, Davide [1 ]
Pasini, Pietro Mario [1 ]
Manfredini, Mattia [2 ]
Scognamiglio, Cristian [3 ]
Orsina, Andrea Alain [1 ]
Farronato, Marco [4 ]
机构
[1] Univ Insubria, Sch Dent, Dept Med & Surg, Varese, Italy
[2] Corso Europa 10, I-20122 Milan, Italy
[3] Corso Vittoria 744, I-21042 Varese, Italy
[4] Fdn IRCCS Ca Granda Osped Maggiore Policlin, Dept Orthodont, Sch Dent, Milan, Italy
关键词
Dental implants; Aesthetics; Tissue height; Tissue thickness; Conical implant-abutment connection; Platform switching; SOFT-TISSUE; ANTERIOR MAXILLA; POST-EXTRACTION; BONE-LEVEL; SINGLE; IMMEDIATE; RESTORATIONS; ADAPTATION; OUTCOMES; SITES;
D O I
10.1186/s12903-020-1037-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background To compare tissue response to two implant systems, featuring internal hexed connections with different designs. Methods Patients enrolled in this randomized controlled trial were assigned to two groups. In Group 1, patients were treated with implants with a 5 degrees conical internal hexed connection (Anyridge (R), MegaGen, South Korea). In Group 2, patients were treated with implants with an internal hexed connection (Core (R), Kristal, Italy). After implant placement and a provisionalisation period of 12 months, impressions were taken, stone casts were poured and digitised with a desktop scanner (D700 (R), 3Shape, Copenhagen, Denmark). In a digital environment, for each fixture, two values were collected at the buccal zenith: the height of the peri-implant mucosa (mucosal height; MH), calculated from the vestibular shoulder of the implant analogue to the upper gingival margin of the supra-implant tissue; and the width of the peri-implant mucosa (mucosal thickness; MT), calculated from the vestibular shoulder of the analogue to the external mucosa point perpendicular to the implant major axis. The mean and standard deviation for MH and MT, as well as their ratios, were calculated for each group; the sectors in which the implants were placed were also considered. Finally, correlation between MH, MT, connection type and sector was assessed by Pearson's correlation coefficient, with significance level set at 0.05, and a confidence interval (CI) set at 95%. Results Data deriving from 188 implants placed in 104 patients were evaluated. The mean MH values were 3.32 (+/- 0.12) and 2.70 (+/- 0.16) mm for Groups 1 and 2, respectively. The mean MT values were 4.37 (+/- 0.16) and 3.93 (+/- 0.18) mm for Groups 1 and 2, respectively. Group 1 showed higher MH and MT values and a better ratio (1.50 +/- 0.88) than Group 2 (1.81 +/- 1.20). The MH, MT and MH/MT ratio were significantly influenced both by sector (p = 0.015) and group (p = 0.047). Conclusions Within the limits of this study, the 5 degrees connection implants supported a more extended tissue height and thickness at the buccal zenith, and a better ratio between them.
引用
收藏
页数:11
相关论文
共 6 条
  • [1] Influence of the implant-abutment connection on the ratio between height and thickness of tissues at the buccal zenith: a randomized controlled trial on 188 implants placed in 104 patients
    Davide Farronato
    Pietro Mario Pasini
    Mattia Manfredini
    Cristian Scognamiglio
    Andrea Alain Orsina
    Marco Farronato
    BMC Oral Health, 20
  • [2] Impact of implant-abutment connection on osteoimmunological and microbiological parameters in short implants: a randomized controlled clinical trial
    Ozturk, Veli Ozgen
    Emingil, Gulnur
    Bostanci, Nagihan
    Belibasakis, Georgios N.
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (09) : E111 - E120
  • [3] Influence of Implant-Abutment Interface Design on Bone and Soft Tissue Levels Around Immediately Placed and Restored Single-Tooth Implants: A Randomized Controlled Clinical Trial
    Pieri, Francesco
    Aldini, Nicolo Nicoli
    Marchetti, Claudio
    Corinaldesi, Giuseppe
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (01) : 169 - 178
  • [4] Influence of implant-abutment connection structure on peri-implant bone level in a second molar: A 1-year randomized controlled trial
    Kim, Jin-Cheol
    Lee, Jungwon
    Kim, Sungtae
    Koo, Ki-Tae
    Kim, Hae-Young
    Yeo, In-Sung Luke
    JOURNAL OF ADVANCED PROSTHODONTICS, 2019, 11 (03): : 147 - 154
  • [5] The influence of abutment macro-design on clinical and radiographic peri-implant tissue changes for guided, placed, and restored implants: A 1-year randomized controlled trial
    Koutouzis, Theofilos
    Adeinat, Bashar
    Ali, Abdulaziz
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (09) : 882 - 891
  • [6] The Influence of Abutment Macrodesign on Facial Peri-implant Tissue Dimensions for Guided Placed and Restored Implants at Healed Sites: 1-Year CBCT Findings from a Randomized Controlled Clinical Trial
    Koutouzis, Theofilos
    Ali, Abdulaziz
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2021, 41 (02) : 277 - +