The influence of the connection, length and diameter of an implant on bone biomechanics

被引:15
|
作者
Borie, Eduardo [1 ,2 ]
Orsi, Iara Augusta [2 ]
de Araujo, Carlos P. R. [3 ]
机构
[1] Univ La Frontera, Sch Dent, CIMOFIR Res Ctr, Temuco 4781176, Chile
[2] Univ Sao Paulo, Ribeirao Preto Dent Sch, Dent Mat & Prosthodont Dept, Ribeirao Preto, SP, Brazil
[3] Univ Sao Paulo, Sch Dent Bauru, Dept Prosthodont, Bauru, SP, Brazil
关键词
biomechanics; bone; dental implants; implant connection; FINITE-ELEMENT-ANALYSIS; INTERNAL CONICAL INTERFACE; FIXED PARTIAL PROSTHESES; STRESS-DISTRIBUTION; OSSEOINTEGRATED IMPLANTS; ABUTMENT INTERFACE; EXTERNAL-HEXAGON; IN-VITRO; DENTAL IMPLANTS; PHOTOELASTIC ANALYSIS;
D O I
10.3109/00016357.2014.961957
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background. Regardless of the multiple options of connections, diameters and heights for dental implants, the clinician should know the biomechanical behavior of the bone to plan the treatment according to the biological and anatomical conditions of each patient, without risk to the long-term treatment success. Review. The following review attempts to summarize the relevant literature to establish guidelines for clinicians based on the scientific evidence regarding the influence by the implant's connection, diameter and length on the bone biomechanics. Conclusions. The length, diameter and connection of each implant have a degree of influence in bone biomechanics. Despite the influence of different implant connections, diameters and lengths on peri-implant bone stress and strain, these characteristics should remain within the physiological limits to avoid a pathological overload, bone resorption and consequent risk to the long-term success of implant-prosthetic treatment.
引用
收藏
页码:321 / 329
页数:9
相关论文
共 50 条
  • [21] Influence of the Crown-Implant Connection on the Preservation of Peri-Implant Bone: A Retrospective Multifactorial Analysis
    Galindo-Moreno, Pablo
    Fernandez-Jimenez, Andres
    O'Valle, Francisco
    Monje, Alberto
    Silvestre, Francisco J.
    Juodzbalys, Gintaras
    Sanchez-Fernandez, Elena
    Catena, Andres
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (02) : 384 - 390
  • [22] Influence of Implant/Abutment Connection on Stress Distribution to Implant-Surrounding Bone: A Finite Element Analysis
    Hanaoka, Marcia
    Alexandre Gehrke, Sergio
    Mardegan, Fabio
    Gennari, Cesar Roberto
    Taschieri, Silvio
    Del Fabbro, Massimo
    Corbella, Stefano
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (07): : 565 - 571
  • [23] Finite element analysis on influence of implant surface treatments, connection and bone types
    Santiago Junior, Joel Ferreira
    Verri, Fellippo Ramos
    de Faria Almeida, Daniel Augusto
    de Souza Batista, Victor Eduardo
    Araujo Lemos, Cleidiel Aparecido
    Pellizzer, Eduardo Piza
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 63 : 292 - 300
  • [24] Influence of Implant Length and Diameter, Bicortical Anchorage, and Sinus Augmentation on Bone Stress Distribution: Three-Dimensional Finite Element Analysis
    Moriwaki, Hiroyoshi
    Yamaguchi, Satoshi
    Nakano, Tamaki
    Yamanishi, Yasufumi
    Imazato, Satoshi
    Yatani, Hirofumi
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (04) : E84 - E91
  • [25] Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols-An In Vitro Analysis
    Stoilov, Milan
    Shafaghi, Ramin
    Stark, Helmut
    Marder, Michael
    Kraus, Dominik
    Enkling, Norbert
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (09)
  • [26] Influence of Orthotropy on Biomechanics of Peri-Implant Bone in Complete Mandible Model with Full Dentition
    Ding, Xi
    Liao, Sheng-Hui
    Zhu, Xing-Hao
    Wang, Hui-Ming
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [27] Biomechanics of femoral interlocking nails in the bone implant complex
    Schandelmaier, P
    Farouk, O
    Krettek, C
    Mannss, J
    Tscherne, H
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1997, 382 (03): : 167 - 172
  • [28] Influence of simulated bone-implant contact and implant diameter on secondary stability: a resonance frequency in vitro study
    Veltri, Mario
    Gonzalez-Martin, Oscar
    Belser, Urs C.
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (08) : 899 - 904
  • [29] Influence of bone density and implant drill diameter on the resulting axial force and temperature development in implant burs and artificial bone: an in vitro study
    Möhlhenrich S.C.
    Abouridouane M.
    Heussen N.
    Modabber A.
    Klocke F.
    Hölzle F.
    Oral and Maxillofacial Surgery, 2016, 20 (2) : 135 - 142
  • [30] Finite element analysis of mini implant biomechanics on peri-implant bone
    Hisam, Muhammad Juzaili
    Zaman, Izzuddin
    Shari, Safian
    Kurniawan, Denni
    Nor, Fethma M.
    DIGITAL MANUFACTURING TRANSFORMING INDUSTRY TOWARDS SUSTAINABLE GROWTH, 2019, 30 : 308 - 314