Amperometric hydrogen peroxide sensor using carbon electrode loaded with perovskite-type oxide

被引:2
|
作者
Takase, S [1 ]
Ishikawa, A [1 ]
Shimizu, Y [1 ]
机构
[1] Kyushu Inst Technol, Fac Engn, Dept Appl Chem, Kitakyushu, Fukuoka 8048550, Japan
关键词
H2O2; sensor; Perovskite-type oxide; amperometric sensing; solid polymer electrolyte;
D O I
10.5796/electrochemistry.69.272
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Amperometric sensing properties to H2O2 of the carbon electrodes loaded with various perovskite-type oxides have been investigated. It was found that the carbon electrodes loaded with perovskite-type oxides showed high activity to anodic reaction including H2O2. A limiting current was observed at the electrode potential between 0.7 and 1.0 V vs. SCE. and the current at a fixed potential increased with increasing H2O2 concentration between 10 and 1000 muM (M = mol dm(-3)). H2O2 responses of the elements loaded with La0.6Ca0.4BO3 (B = Fe and Cr) were hardly affected by dissolved oxygen. All solid-state H2O2 sensor element based on solid polymer electrolyte and La0.6Ca0.4FeO3-based electrodes also responded well to H2O2 at the concentration between 50 and 200 muM, with the 90% response time of as short as 20 s.
引用
收藏
页码:272 / 275
页数:4
相关论文
共 50 条
  • [1] Sensing characteristics of hydrogen peroxide sensor using carbon-based electrode loaded with perovskite-type oxide
    Shimizu, Y
    Komatsu, H
    Michishita, S
    Miura, N
    Yamazo, N
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1996, 34 (1-3) : 493 - 498
  • [2] Amperometric phosphate-ion sensor using perovskite-type oxide-based electrode
    Shimizu, Y
    Takase, S
    Iseki, K
    Ishikawa, A
    [J]. CHEMICAL SENSORS IV, PROCEEDINGS OF THE SYMPOSIUM, 1999, 99 (23): : 38 - 47
  • [3] Perovskite-type oxide-based electrode: A new sensor for hydrogen-phosphate ion
    Shimizu, Y
    Ishikawa, A
    Iseki, K
    Takase, S
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2000, 147 (10) : 3931 - 3934
  • [4] Amperometric-type NOx sensor based on YSZ electrolyte and La-based perovskite-type oxide sensing electrode
    Ueda, Taro
    Nagano, Takayuki
    Okawa, Hajime
    Takahashi, Seiji
    [J]. JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 2010, 118 (1375) : 180 - 183
  • [5] Solid electrolyte CO2 sensor using NASICON and perovskite-type oxide electrode
    Shimizu, Y
    Yamashita, N
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 64 (1-3) : 102 - 106
  • [6] Sensing Properties of Solid Electrolyte NOx Sensor Using NASICON and Perovskite-Type Oxide Electrode
    Takahashi, Hiromi
    Takase, Satoko
    Shimizu, Youichi
    [J]. IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2023, 18 (06) : 989 - 991
  • [7] Zirconia-based amperometric sensor using La-Sr-based perovskite-type oxide sensing electrode for detection of NO2
    Ueda, Taro
    Nagano, Takayuki
    Okawa, Hajime
    Takahashi, Seiji
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (08) : 1654 - 1656
  • [8] An Efficient Amperometric Sensor for Hydrogen Peroxide by Using a Carbon Paste Electrode Modified with Cobalt Impregnated Zeolite
    Norouzi, Banafsheh
    Moradian, Majid
    Malekan, Ali
    [J]. PORTUGALIAE ELECTROCHIMICA ACTA, 2015, 33 (02) : 111 - 124
  • [9] Amperometric Sensing of Hydrogen Peroxide Using Graphene Oxide-Alizarin Modified Glassy Carbon Electrode
    Muhammet, Sinan Mithat
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (06):
  • [10] An Amperometric Hydrogen Peroxide Sensor Based on Reduced Graphene Oxide/Carbon Nanotubes/Pt NPs Modified Glassy Carbon Electrode
    Zhang, Yuanyuan
    Cao, Qi
    Zhu, Fengmei
    Xu, Hedan
    Zhang, Yang
    Xu, Wenfeng
    Liao, Xiaoling
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (09): : 8771 - 8785