Amperometric Sensing of Hydrogen Peroxide Using Graphene Oxide-Alizarin Modified Glassy Carbon Electrode

被引:1
|
作者
Muhammet, Sinan Mithat [1 ]
机构
[1] Gazi Univ, Vocat Sch Tech Sci, Dept Mat & Mat Proc Technol, Ankara, Turkey
来源
关键词
Hydrogen peroxide; Alizarin; Graphene oxide; Glassy carbon electrode; ELECTROCHEMICAL DETERMINATION; BIOSENSOR; IMMOBILIZATION; FILM; NANOPARTICLES; CHOLESTEROL; NANOTUBES; URICASE;
D O I
10.20964/2022.06.12
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A sensitive and selective amperometric sensor for hydrogen peroxide was constructed by mixing graphene oxide (GO) and alizarin red (Ali) at certain amounts, and dropping it onto a glassy carbon electrode (GC). The freshly prepared electrode (Ali-GO/GC) was activated by voltage scans at the range of -0.6 V and 0.9 V for ten cycles. Activated Ali-GO/GC has possessed a reversible redox activity in both anodic and cathodic directions. Ali-GO/GC exhibits a suitable electrocatalytic activity against hydrogen peroxide towards the anodic redox region with a linear range from 3.6 mu M to 513 mu M of H2O2 and a detection limit of 1.1 mu M. Ali-GO/GC displays selectivity, relatively high sensitivity, and reproducibility at the amperometric analysis of hydrogen peroxide.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Amperometric sensing of hydrogen peroxide using glassy carbon electrode modified with copper nanoparticles
    Sophia, J.
    Muralidharan, G.
    [J]. MATERIALS RESEARCH BULLETIN, 2015, 70 : 315 - 320
  • [2] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    Noor, An'amt Mohamed
    Shahid, Muhammad Mehmood
    Rameshkumar, Perumal
    Huang, Nay Ming
    [J]. MICROCHIMICA ACTA, 2016, 183 (02) : 911 - 916
  • [3] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    An’amt Mohamed Noor
    Muhammad Mehmood Shahid
    Perumal Rameshkumar
    Nay Ming Huang
    [J]. Microchimica Acta, 2016, 183 : 911 - 916
  • [4] A modified glassy carbon electrode for hydrogen peroxide sensing
    Zheng, Cai-yun
    Chen, Shui-hong
    Shang, Yong-jia
    Li, Mao-guo
    [J]. ANNALI DI CHIMICA, 2007, 97 (11-12) : 1227 - 1235
  • [5] Sensing hydrogen peroxide with a glassy carbon electrode modified with silver nanoparticles, AlOOH and reduced graphene oxide
    Ziyin Yang
    Chengcheng Qi
    Xiaohui Zheng
    Jianbin Zheng
    [J]. Microchimica Acta, 2016, 183 : 1131 - 1136
  • [6] Sensing hydrogen peroxide with a glassy carbon electrode modified with silver nanoparticles, AlOOH and reduced graphene oxide
    Yang, Ziyin
    Qi, Chengcheng
    Zheng, Xiaohui
    Zheng, Jianbin
    [J]. MICROCHIMICA ACTA, 2016, 183 (03) : 1131 - 1136
  • [7] Amperometric sensing of catechol using a glassy carbon electrode modified with ferrocene covalently immobilized on graphene oxide
    Elancheziyan, Mari
    Manoj, Devaraj
    Saravanakumar, Duraisamy
    Thenmozhi, Kathavarayan
    Senthilkumar, Sellappan
    [J]. MICROCHIMICA ACTA, 2017, 184 (08) : 2925 - 2932
  • [8] Amperometric sensing of catechol using a glassy carbon electrode modified with ferrocene covalently immobilized on graphene oxide
    Mari Elancheziyan
    Devaraj Manoj
    Duraisamy Saravanakumar
    Kathavarayan Thenmozhi
    Sellappan Senthilkumar
    [J]. Microchimica Acta, 2017, 184 : 2925 - 2932
  • [9] An Amperometric Hydrogen Peroxide Sensor Based on Reduced Graphene Oxide/Carbon Nanotubes/Pt NPs Modified Glassy Carbon Electrode
    Zhang, Yuanyuan
    Cao, Qi
    Zhu, Fengmei
    Xu, Hedan
    Zhang, Yang
    Xu, Wenfeng
    Liao, Xiaoling
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (09): : 8771 - 8785
  • [10] Photoelectrochemical amperometric sensing of cyanide using a glassy carbon electrode modified with graphene oxide and titanium dioxide nanoparticles
    Rahman Hallaj
    Nasibeh Haghighi
    [J]. Microchimica Acta, 2017, 184 : 3581 - 3590