Amperometric hydrogen peroxide sensor using carbon electrode loaded with perovskite-type oxide

被引:2
|
作者
Takase, S [1 ]
Ishikawa, A [1 ]
Shimizu, Y [1 ]
机构
[1] Kyushu Inst Technol, Fac Engn, Dept Appl Chem, Kitakyushu, Fukuoka 8048550, Japan
关键词
H2O2; sensor; Perovskite-type oxide; amperometric sensing; solid polymer electrolyte;
D O I
10.5796/electrochemistry.69.272
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Amperometric sensing properties to H2O2 of the carbon electrodes loaded with various perovskite-type oxides have been investigated. It was found that the carbon electrodes loaded with perovskite-type oxides showed high activity to anodic reaction including H2O2. A limiting current was observed at the electrode potential between 0.7 and 1.0 V vs. SCE. and the current at a fixed potential increased with increasing H2O2 concentration between 10 and 1000 muM (M = mol dm(-3)). H2O2 responses of the elements loaded with La0.6Ca0.4BO3 (B = Fe and Cr) were hardly affected by dissolved oxygen. All solid-state H2O2 sensor element based on solid polymer electrolyte and La0.6Ca0.4FeO3-based electrodes also responded well to H2O2 at the concentration between 50 and 200 muM, with the 90% response time of as short as 20 s.
引用
收藏
页码:272 / 275
页数:4
相关论文
共 50 条
  • [21] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    An’amt Mohamed Noor
    Muhammad Mehmood Shahid
    Perumal Rameshkumar
    Nay Ming Huang
    [J]. Microchimica Acta, 2016, 183 : 911 - 916
  • [22] An Amperometric Hydrogen Peroxide Sensor Based on Hollow Carbon Spheres/Pt NPs Modified Glassy Carbon Electrode
    Zhang, Yuanyuan
    Duan, Hongliang
    Yuan, Wang
    Li, Yunlong
    Zhang, Yueqi
    Yang, Xiaoling
    Liao, Xiaoling
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (12):
  • [23] Amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with a nanocomposite prepared from ferumoxytol and reduced graphene oxide decorated with platinum nanoparticles
    Zhang, Yuanyuan
    Duan, Yulin
    Shao, Zeyu
    Chen, Chen
    Yang, Mei
    Lu, Guodong
    Xu, Wenfeng
    Liao, Xiaoling
    [J]. MICROCHIMICA ACTA, 2019, 186 (06)
  • [24] Amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with a nanocomposite prepared from ferumoxytol and reduced graphene oxide decorated with platinum nanoparticles
    Yuanyuan Zhang
    Yulin Duan
    Zeyu Shao
    Chen Chen
    Mei Yang
    Guodong Lu
    Wenfeng Xu
    Xiaoling Liao
    [J]. Microchimica Acta, 2019, 186
  • [25] Amperometric sensing of hydrogen peroxide using glassy carbon electrode modified with copper nanoparticles
    Sophia, J.
    Muralidharan, G.
    [J]. MATERIALS RESEARCH BULLETIN, 2015, 70 : 315 - 320
  • [26] A hydrogen-phosphate ion sensor using solid electrolyte impedance transducer and perovskite-type oxide receptor
    Yoshida, M
    Ibrahim, NB
    Aung, YL
    Takase, S
    Shimizu, Y
    [J]. ELECTROCHEMISTRY, 2006, 74 (02) : 163 - 165
  • [27] Solid electrolyte NOx gas sensor using perovskite-type oxide electrodes
    Yoon, JW
    Grilli, ML
    Di Bartolomeo, E
    Traversa, E
    [J]. SENSORS AND MICROSYSTEMS, 2000, : 192 - 196
  • [28] Formation of perovskite-type oxide electrode Si substrate structures
    Sakai, J
    Imai, S
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2004, 45 : S752 - S755
  • [29] Application of pyrite and chalcopyrite as sensor electrode for amperometric detection and measurement of hydrogen peroxide
    Wang, Y.
    Zhao, K. J.
    Tao, D. P.
    Zhai, F. G.
    Yang, H. B.
    Zhang, Z. Q.
    [J]. RSC ADVANCES, 2018, 8 (09): : 5013 - 5019
  • [30] Phosphomolybdate-polypyrrole composite bulk-modified carbon paste electrode for a hydrogen peroxide amperometric sensor
    Wang, XL
    Zhang, H
    Wang, EB
    Han, ZB
    Hu, CW
    [J]. MATERIALS LETTERS, 2004, 58 (10) : 1661 - 1664