Investigation on the Energy Saving Potential of Using a Novel Dew Point Cooling System in Data Centres

被引:11
|
作者
Bi, Yin [1 ,2 ]
Wang, Yugang [1 ,3 ]
Ma, Xiaoli [1 ]
Zhao, Xudong [1 ]
机构
[1] Univ Hull, Sch Engn & Comp Sci, Kingston Upon Hull HU6 7RX, Yorks, England
[2] Guangdong Univ Technol, Sch Civil & Transportat Engn, Guangzhou 510006, Guangdong, Peoples R China
[3] Jimei Univ, Sch Mech & Energy Engn, Xiamen 361021, Peoples R China
来源
ENERGIES | 2017年 / 10卷 / 11期
基金
欧盟地平线“2020”; 英国工程与自然科学研究理事会;
关键词
dew point cooling; data centres; energy saving; energy usage effectiveness; cooling load; INDIRECT EVAPORATIVE COOLER; COUNTER-FLOW; HEAT-EXCHANGERS; PERFORMANCE; OPTIMIZATION; CONSERVATION;
D O I
10.3390/en10111732
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Information technology (IT) has brought significant changes in people's lives. As an important part of the IT industry, data centres (DCs) have been rapidly growing in both the number and size over the past 40 years. Around 30% to 40% of electricity consumption in DCs is used for space cooling, thus leading to very inefficient DC operation. To identify ways to reduce the energy consumption for space cooling and increase the energy efficiency of DCs' operation, a dedicated investigation into the energy usage in DCs has been undertaken and a novel high performance dew point cooling system was introduced into a DC operational scheme. Based on the cooling load in DCs, a case study was carried out to evaluate the energy consumptions and energy usage effectiveness when using the novel dew point cooling system in different scales of DCs in various climates. It was found that by using the novel dew point cooling system, for 10 typical climates a DC can have a much lower power usage effectiveness (PUE) of 1.10 to 1.22 compared to that of 1.7 to 3.7 by using existing traditional cooling systems, leading to significantly increased energy efficiency of the DC operation. In addition, the energy performance by managing the cooling air supply at the different levels in DCs, i.e., room, row and rack level, was simulated by using a dynamic computer model. It was found that cooling air supply at rack level can provide a higher energy efficiency in DCs. Based on the above work, the energy saving potential in DCs was conducted by comparing DCs using an the novel dew point cooling system and the optimum management scheme for the cooling air supply to that using traditional air cooling systems and the same supply air management. Annual electricity consumptions for the two cases were given. It was found that by using the novel dew point cooling system and optimum management system for the cooling air supply, an 87.7-91.6% electricity consumption saving for space cooling in DCs could be achieved in 10 typical cities at 10 selected climatic conditions.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Application Potential of a Dew-Point Cooling Tower in Selected Energy Intensive Applications in Temperate Climate
    Pandelidis, Demis
    Matuszczak, Mikolaj
    Krowicki, Pawel
    Poskart, Bartosz
    Iskierka, Grzegorz
    Worek, William
    Cetin, Sabri
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [22] Numerical study on performance of the dew point evaporative cooling system
    Liu, Xuliang
    Jing, Chengjun
    Zhao, Yan
    Miyazaki, Takahiko
    JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2021, 16 (03)
  • [23] Experimental investigation on a novel integrated system of vapor compression and pump-driven two phase loop for energy saving in data centers cooling
    Ma, Yuezheng
    Ma, Guoyuan
    Zhang, Shuang
    Xu, Shuxue
    ENERGY CONVERSION AND MANAGEMENT, 2015, 106 : 194 - 200
  • [24] Energy saving evaluation of a novel energy system based on spray cooling for supercomputer center
    Chen, Hua
    Cheng, Wen-long
    Zhang, Wei-wei
    Peng, Yu-hang
    Jiang, Li-jia
    ENERGY, 2017, 141 : 304 - 315
  • [25] Simulation of energy saving potential of a centralized HVAC system in an academic building using adaptive cooling technique
    Bhaskoro, Petrus Tri
    Gilani, Syed Ihtsham Ul Haq
    Aris, Mohd Shiraz
    ENERGY CONVERSION AND MANAGEMENT, 2013, 75 : 617 - 628
  • [26] The possibility of using a novel dew point air cooling system (M-Cycle) for A/C application in Arab Gulf Countries
    Baakeem, Saleh S.
    Orfi, Jamel
    Mohamad, Abdulmajeed
    Bawazeer, Saleh
    BUILDING AND ENVIRONMENT, 2019, 148 : 185 - 197
  • [27] Performance and Economical Analyses of a Dew Point Evaporative Cooling System Using Stepwise Regression Approach
    Sohani, Ali
    Hasani-Balyani, Hamidreza
    Sayyaadi, Hoseyn
    Maisotsenko, Valeriy
    2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [28] Overview of direct air free cooling and thermal energy storage potential energy savings in data centres
    Oro, Eduard
    Depoorter, Victor
    Pflugradt, Noah
    Salom, Jaume
    APPLIED THERMAL ENGINEERING, 2015, 85 : 100 - 110
  • [29] Analytical investigation of the dew point water recovery system with potential application for drinking water production
    Cichon, Aleksandra
    Wartalska, Katarzyna
    Grzegorzek, Martyna
    Kazmierczak, Bartosz
    Worek, William
    Cetin, Sabri
    Pandelidis, Demis
    DESALINATION, 2023, 564
  • [30] Analysis of Suitable Thermodynamic Properties and Conditions for Dew Point Cooling system
    Noramzil, N. N. A.
    Razlan, Z. M.
    Zunaidi, I.
    Izham, M.
    Shahriman, A. B.
    Harun, A.
    Hashim, M. S. M.
    Faizi, M. K.
    Ibrahim, I.
    Kamarrudin, N. S.
    Wan, W. K.
    Rani, M. F. H.
    INTERNATIONAL CONFERENCE ON ADVANCED MANUFACTURING AND INDUSTRY APPLICATIONS, 2018, 429