A prototype small CdTe gamma camera for radioguided surgery and other imaging applications

被引:52
|
作者
Tsuchimochi, M
Sakahara, H
Hayama, K
Funaki, M
Ohno, R
Shirahata, T
Orskaug, T
Maehlum, G
Yoshioka, K
Nygard, E
机构
[1] Nippon Dent Univ, Sch Dent Niigata, Dept Oral & Maxillofacial Radiol, Niigata 9518580, Japan
[2] Hamamatsu Univ Sch Med, Dept Radiol, Hamamatsu, Shizuoka 43131, Japan
[3] Acrorad Co Ltd, Tokyo, Japan
[4] Integrated Detector & Elect AS, Hovik, North Ireland
关键词
CdTe; gamma camera; semiconductor; sentinel lymph node biopsy; radioguided surgery;
D O I
10.1007/s00259-003-1301-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mmx166 mmx65 rum. The effective visual field was 44.8 mmx44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV (Tc-99m), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM had a mean value of 1.56+/-0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and facilitating subsequent radioguided surgery.
引用
收藏
页码:1605 / 1614
页数:10
相关论文
共 50 条
  • [41] An intensified EMCCD camera for low energy gamma ray imaging applications
    Meng, L. J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (04) : 2376 - 2384
  • [42] C-SPRINT: A prototype Compton camera system for low energy gamma ray imaging
    LeBlanc, JW
    Clinthorne, NH
    Hua, CH
    Nygard, E
    Rogers, WL
    Wehe, DK
    Weilhammer, P
    Wilderman, SJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 943 - 949
  • [43] C-SPRINT: A prototype Compton camera system for low energy gamma ray imaging
    LeBlanc, JW
    Clinthorne, NH
    Hua, CH
    Nygard, E
    Rogers, WL
    Wehe, DK
    Weilhammer, P
    Wilderman, SJ
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 357 - 361
  • [44] Radioguided surgery with combined use of gamma probe and hand-held gamma camera for treatment of papillary thyroid cancer locoregional recurrences: a preliminary study
    Bellotti, C.
    Castagnola, G.
    Tierno, S. M.
    Centanini, F.
    Sparagna, A.
    Vetrone, I.
    Mezzetti, G.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2013, 17 (24) : 3362 - 3366
  • [45] Prototype gamma-ray computed tomographic imaging system for industrial applications
    Kumar, U
    Ramakrishna, GS
    Datta, SS
    Ravindran, VR
    INSIGHT, 2000, 42 (10) : 662 - 666
  • [46] Prototype gamma-ray computed tomographic imaging system for industrial applications
    Kumar, Umesh
    Ramakrishna, G.S.
    Datta, S.S.
    Ravindran, V.R.
    Insight: Non-Destructive Testing and Condition Monitoring, 2000, 42 (10): : 662 - 666
  • [47] Annihilation gamma imaging for carbon ion beam range monitoring using Si/CdTe Compton camera
    Parajuli, Raj Kumar
    Sakai, Makoto
    Kada, Wataru
    Torikai, Kota
    Kikuchi, Mikiko
    Arakawa, Kazuo
    Torikoshi, Masami
    Nakano, Takashi
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (05):
  • [48] Optimized collimator designs for small animal SPECT imaging with a compact gamma camera
    Qi, Yujin
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1780 - 1782
  • [49] Use of a compact pixellated gamma camera for small animal pinhole SPECT imaging
    Tsutomu Zeniya
    Hiroshi Watabe
    Toshiyuki Aoi
    Kyeong Min Kim
    Noboru Teramoto
    Takeshi Takeno
    Yoichiro Ohta
    Takuya Hayashi
    Hiroyuki Mashino
    Toshihiro Ota
    Seiichi Yamamoto
    Hidehiro Iida
    Annals of Nuclear Medicine, 2006, 20 : 409 - 416
  • [50] ANALYSIS OF GAMMA-CAMERA IMAGING DATA BY A SMALL DIGITAL-COMPUTER
    DUGDALE, LM
    FEIGLIN, DH
    AUSTRALASIAN RADIOLOGY, 1973, 17 (02): : 221 - 228