A prototype small CdTe gamma camera for radioguided surgery and other imaging applications

被引:52
|
作者
Tsuchimochi, M
Sakahara, H
Hayama, K
Funaki, M
Ohno, R
Shirahata, T
Orskaug, T
Maehlum, G
Yoshioka, K
Nygard, E
机构
[1] Nippon Dent Univ, Sch Dent Niigata, Dept Oral & Maxillofacial Radiol, Niigata 9518580, Japan
[2] Hamamatsu Univ Sch Med, Dept Radiol, Hamamatsu, Shizuoka 43131, Japan
[3] Acrorad Co Ltd, Tokyo, Japan
[4] Integrated Detector & Elect AS, Hovik, North Ireland
关键词
CdTe; gamma camera; semiconductor; sentinel lymph node biopsy; radioguided surgery;
D O I
10.1007/s00259-003-1301-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mmx166 mmx65 rum. The effective visual field was 44.8 mmx44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV (Tc-99m), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM had a mean value of 1.56+/-0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and facilitating subsequent radioguided surgery.
引用
收藏
页码:1605 / 1614
页数:10
相关论文
共 50 条
  • [21] LaBr3:Ce scintillation gamma camera prototype for X and gamma ray imaging
    Pani, R.
    Cinti, M. N.
    Pellegrini, R.
    Bennati, P.
    Betti, M.
    Vittorini, F.
    Mattioli, M.
    Trotta, G.
    Cencelli, V. Orsolini
    Scafe, R.
    Navarria, F.
    Bollini, D.
    Baldazzi, G.
    Moschini, G.
    De Notaristefani, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 15 - 18
  • [22] Intraoperative gamma cameras for radioguided surgery: Technical characteristics, performance parameters, and clinical applications
    Tsuchimochi, Makoto
    Hayama, Kazuhide
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (02): : 126 - 138
  • [23] Imaging performance of a prototype hand-held gamma camera for surgical use
    Tsuchimochi, M
    Sakahara, H
    Hayama, K
    Funaki, M
    Shirahata, T
    Orskaug, T
    RADIOLOGY, 2001, 221 : 127 - 127
  • [24] Studies of Prototype Dual Head Compton Camera for Applications in Medical Imaging
    Peterson, S.
    Leigh, M.
    Mackin, D.
    Chen, H.
    Maggi, P.
    Beddar, S.
    Polf, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E491 - E491
  • [25] Role of a portable gamma-camera with optical view for margins assessment of pulmonary nodules resected by radioguided surgery
    Ivan Vollmer
    Nuria Sánchez-Izquierdo
    Daniel Martínez
    David Sánchez-Lorente
    Sebastián Casanueva-Eliceiry
    Marc Boada
    Ángela Guirao
    Inmaculada Romero-Zayas
    Sergi Vidal-Sicart
    Pilar Paredes
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 49 : 361 - 370
  • [26] Evaluation of a CdTe semiconductor based compact gamma camera for sentinel lymph node imaging
    Russo, Paolo
    Curion, Assunta S.
    Mettivier, Giovanni
    Esposito, Michela
    Aurilio, Michela
    Caraco, Corradina
    Aloj, Luigi
    Lastoria, Secondo
    MEDICAL PHYSICS, 2011, 38 (03) : 1547 - 1560
  • [27] Radioguided surgery using a portable gamma camera in a patient with mediastinal parathyroid adenoma by video-assisted thoracoscopy
    Arias, C. Castillo
    Tormo, I. Casans
    Rodriguez Parra, H.
    Carrero Vasquez, V.
    Asensio Valero, L.
    Redal Pena, M.
    Perez Castro, N. A.
    Carcamo Ibarra, P. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S673 - S673
  • [28] Role of a portable gamma-camera with optical view for margins assessment of pulmonary nodules resected by radioguided surgery
    Vollmer, Ivan
    Sanchez-Izquierdo, Nuria
    Martinez, Daniel
    Sanchez-Lorente, David
    Casanueva-Eliceiry, Sebastian
    Boada, Marc
    Guirao, Angela
    Romero-Zayas, Inmaculada
    Vidal-Sicart, Sergi
    Paredes, Pilar
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 49 (01) : 361 - 370
  • [29] IMAGING WITH A SMALL ULTRA PURE GERMANIUM GAMMA-CAMERA
    KAUFMAN, L
    HATTNER, R
    PRICE, D
    SWANN, S
    HUBERTY, J
    ARMANTROUT, G
    CAMP, D
    MCQUAID, J
    EWINS, JH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (01) : 395 - 403
  • [30] A small field of view camera for hybrid gamma and optical imaging
    Lees, J. E.
    Bugby, S. L.
    Bhatia, B. S.
    Jambi, L. K.
    Alqahtani, M. S.
    McKnight, W. R.
    Ng, A. H.
    Perkins, A. C.
    JOURNAL OF INSTRUMENTATION, 2014, 9