A prototype small CdTe gamma camera for radioguided surgery and other imaging applications

被引:52
|
作者
Tsuchimochi, M
Sakahara, H
Hayama, K
Funaki, M
Ohno, R
Shirahata, T
Orskaug, T
Maehlum, G
Yoshioka, K
Nygard, E
机构
[1] Nippon Dent Univ, Sch Dent Niigata, Dept Oral & Maxillofacial Radiol, Niigata 9518580, Japan
[2] Hamamatsu Univ Sch Med, Dept Radiol, Hamamatsu, Shizuoka 43131, Japan
[3] Acrorad Co Ltd, Tokyo, Japan
[4] Integrated Detector & Elect AS, Hovik, North Ireland
关键词
CdTe; gamma camera; semiconductor; sentinel lymph node biopsy; radioguided surgery;
D O I
10.1007/s00259-003-1301-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mmx166 mmx65 rum. The effective visual field was 44.8 mmx44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV (Tc-99m), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM had a mean value of 1.56+/-0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and facilitating subsequent radioguided surgery.
引用
收藏
页码:1605 / 1614
页数:10
相关论文
共 50 条
  • [31] Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications
    Verger, L
    Boitel, M
    Gentet, MC
    Hamelin, R
    Mestais, C
    Mongellaz, F
    Rustique, J
    Sanchez, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 297 - 309
  • [32] Hybrid intraoperative imaging techniques in radioguided surgery: present clinical applications and future outlook
    Bugby, S. L.
    Lees, J. E.
    Perkins, A. C.
    CLINICAL AND TRANSLATIONAL IMAGING, 2017, 5 (04) : 323 - 341
  • [33] Hybrid intraoperative imaging techniques in radioguided surgery: present clinical applications and future outlook
    S. L. Bugby
    J. E. Lees
    A. C. Perkins
    Clinical and Translational Imaging, 2017, 5 : 323 - 341
  • [34] THE EXPERIMENTAL EVALUATION OF A PROTOTYPE ROTATING SLAT COLLIMATOR FOR PLANAR GAMMA-CAMERA IMAGING
    LODGE, MA
    BINNIE, DM
    FLOWER, MA
    WEBB, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (03): : 427 - 448
  • [35] Imaging performance of a prototype hand-held gamma camera for surgical use.
    Tsuchimochi, M
    Sakahara, H
    Hayama, K
    Funaki, M
    Shirahata, T
    Orskaug, T
    Maehlum, G
    Yoshioka, K
    Nygard, E
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A506 - A506
  • [36] A prototype: Pixelized small imaging CDTE probe for intra-operative use.
    Vanlingen, A
    Baumann, E
    Bruin, NM
    Ijbema, T
    Fougeres, P
    Teule, GJ
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 203P - 203P
  • [37] Experimental Results of the Gamma-Ray Imaging Capability With a Si/CdTe Semiconductor Compton Camera
    Takeda, Shin'ichiro
    Aono, Hiroyuki
    Okuyama, Sho
    Ishikawa, Shin-nosuke
    Odaka, Hirokazu
    Watanabe, Shin
    Kokubun, Motohide
    Takahashi, Tadayuki
    Nakazawa, Kazuhiro
    TajimaHiro, Hiroyasu
    Kawachi, Naoki
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 783 - 790
  • [38] Sentinel node imaging of laryngeal cancer using a portable gamma camera with CdTe semiconductor detectors
    Tanaka, C
    Fujii, H
    Shiotani, A
    Kitagawa, Y
    Nakamura, K
    Kubo, A
    CLINICAL NUCLEAR MEDICINE, 2005, 30 (06) : 440 - 443
  • [39] SPECT imaging properties of the CdTe-Timepix3 detector used in a new prototype FullSPECT 3D multimodal preclinical imaging system: Comparison with scintillation gamma camera
    Modry, Adam
    Dammer, Jiri
    Trojanova, Eliska
    Jakubek, Jan
    Sykora, Viktor
    Sefc, Ludek
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1032
  • [40] Applicability of a high-resolution small semiconductor gamma camera to small animal imaging
    Kiyono, Yasushi
    Kuge, Yuji
    Katada, Yumiko
    Kawashima, Hidekazu
    Magata, Yasuhiro
    Saji, Hideo
    NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (09) : 736 - 741