Safety verification of carbon-ion radiotherapy for patients with cardiac implantable electronic devices (CIEDs)

被引:2
|
作者
Okano, Naoko [1 ,2 ]
Sakai, Makoto [2 ]
Shibuya, Kei [2 ]
Tsuda, Kazuhisa [3 ]
Kanzaki, Takao [3 ]
Sano, Masato [4 ]
Kaneko, Yoshiaki [5 ]
Ohno, Tatsuya [1 ,2 ]
机构
[1] Gunma Univ, Dept Radiat Oncol, Grad Sch Med, 3-39-15 Showa Machi, Maebashi, Gunma 3718511, Japan
[2] Gunma Univ, Heavy Ion Med Ctr, 3-39-15 Showa Machi, Maebashi, Gunma 3718511, Japan
[3] Gunma Univ Hosp, Dept Radiol, 3-9-15 Showa Machi, Maebashi, Gunma 3718511, Japan
[4] Gunma Univ Hosp, Me Supply Ctr, 3-9-15 Showa Machi, Maebashi, Gunma 3718511, Japan
[5] Gunma Univ, Dept Cardiovasc Med, Grad Sch Med, 3-39-15 Showa Machi, Maebashi, Gunma 3718511, Japan
关键词
pacemaker; cardiac implantable electronic devices (CIEDs); implantable cardioverter-defibrillator (ICD); carbon-ion; radiotherapy; Monte Carlo simulation; DEGRO/DGK-GUIDELINE; LATEST GENERATION; RADIATION; MANAGEMENT; IRRADIATION; EXPOSURE; SYSTEM; ENERGY;
D O I
10.1093/jrr/rrab105
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
According to guidelines, carbon-ion beam therapy is considered to carry a high safety risk for patients with cardiac implantable electronic devices (CIEDs), although the actual impacts remain unclear. In this study, we investigated the safety of carbon-ion beam therapy in patients with CIEDs. Patients with CIEDs who underwent carbon-ion therapy at Gunma University Heavy Ion Medical Center between June 2010 and December 2019 were identified and investigated for abnormalities in the operation of their CIEDs, such as oversensing and resetting during irradiation, and abnormalities in operation after treatment. In addition, the risk of irradiation from carbon-ion beam therapy was evaluated by model simulations. Twenty patients (22 sites) with CIEDs were identified, 19 with pacemakers and one with an implantable cardioverter-defibrillator (ICD). Treatments were completed without any problems, except for one case in which the treatment was discontinued because of worsening of the primary disease. Monte Carlo simulation indicated that the carbon beam irradiation produced neutrons at a constant and high level in the irradiation field. Nevertheless, with the distances between the CIEDs and the irradiation fields in the analyzed cases, the quantity of neutrons at the CIEDs was lower than that within the irradiation. Although carbon-ion beam therapy can be safely administered to patients with CIEDs, it is advisable to perform the therapy with sufficient preparation and backup devices because of the risks involved.
引用
收藏
页码:122 / 127
页数:6
相关论文
共 50 条
  • [41] An attractive shift in polarity: A new algorithm for the perioperative management of cardiac implantable electronic devices (CIEDs)
    Hunter, Caroline B. G.
    Chen, Tzonghuei H.
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2021, 70
  • [42] The Safety of Cardiac and Thoracic Magnetic Resonance Imaging in Patients with Cardiac Implantable Electronic Devices
    Dandamudi, Sanjay
    Collins, Jeremy D.
    Carr, James C.
    Mongkolwat, Pat
    Rahsepar, Amir A.
    Tomson, Todd T.
    Verma, Nishant
    Arora, Rishi
    Chicos, Alex B.
    Kim, Susan S.
    Lin, Albert C.
    Passman, Rod S.
    Knight, Bradley P.
    [J]. ACADEMIC RADIOLOGY, 2016, 23 (12) : 1498 - 1505
  • [43] Radiotherapy in Patients With a Cardiac Implantable Electronic Device
    Sharifzadehgan, Ardalan
    Laurans, Marc
    Thuillot, Marine
    Huertas, Andres
    Baudinaud, Pierre
    Narayanan, Kumar
    Mirabel, Mariana
    Bibault, Jean-Emmanuel
    Frey, Pierre
    Waldmann, Victor
    Varlet, Emilie
    Amet, Denis
    Juin, Christophe
    Lavergne, Thomas
    Jouven, Xavier
    Giraud, Philippe
    Durdux, Catherine
    Marijon, Eloi
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2020, 128 : 196 - 201
  • [44] Cardiac MRI for Patients With Cardiac Implantable Electronic Devices
    Stojanovska, Jadranka
    Runge, Mason
    Mahani, Maryam Ghadimi
    Cronin, Paul P.
    Sayyouh, Mohamed
    Bogun, Frank
    Ibrahim, El-Sayed H.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (02) : 374 - 381
  • [45] Overview of Carbon-ion Radiotherapy
    Tsujii, Hirohiko
    [J]. MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777
  • [46] Safety and Results of Bioelectrical Impedance Analysis in Patients with Cardiac Implantable Electronic Devices
    Garlini, Luiza Matos
    Alves, Fernanda Donner
    Kochi, Adriano
    Zuchinali, Priccila
    Zimerman, Leandro
    Pimentel, Mauricio
    Perry, Ingrid Schweigert
    Souza, Gabriela Correa
    Clausell, Nadine
    [J]. BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2020, 35 (02) : 169 - 169
  • [47] Cardiac implantable electronic devices in tracheotomized muscular dystrophy patients: Safety and risks
    Fayssoil, Abdallah
    Lazarus, Arnaud
    Wahbi, Karim
    Ogna, Adam
    Nardi, Olivier
    Lofaso, Frederic
    Clair, Bernard
    Orlikowski, David
    Annane, Djillali
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 222 : 975 - 977
  • [48] Safety and utility of magnetic resonance imaging in patients with cardiac implantable electronic devices
    Strom, Jordan B.
    Whelan, Jill B.
    Shen, Changyu
    Zheng, Shuang Qi
    Mortele, Koenraad J.
    Kramer, Daniel B.
    [J]. HEART RHYTHM, 2017, 14 (08) : 1138 - 1144
  • [49] Reconsidering safety and reducing barriers to MRI in patients with cardiac implantable electronic devices
    Bucciarelli-Ducci, Chiara
    Vardas, Panos
    [J]. EUROPEAN HEART JOURNAL, 2022, 43 (26) : 2479 - 2481
  • [50] Safety of Oncologic Proton Beam Therapy in Patients With Cardiac Implantable Electronic Devices
    van Zyl, Martin
    Garces, Yolanda I.
    Raina, Anvi
    Remmes, Nicholas B.
    Schroeder, Sarah J.
    Anderson, Sandra S. J.
    Stuart-Mullen, Lynette G.
    Brinkmann, Debra H.
    Bradley, David J.
    Cha, Yong-Mei
    [J]. JACC-CLINICAL ELECTROPHYSIOLOGY, 2022, 8 (11) : 1453 - 1455