A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage

被引:30
|
作者
Juras, Vladimir [1 ,2 ]
Bohndorf, Klaus [1 ]
Heule, Rahel [3 ]
Kronnerwetter, Claudia [1 ]
Szomolanyi, Pavol [1 ,2 ]
Hager, Benedikt [1 ]
Bieri, Oliver [3 ]
Zbyn, Stefan [1 ]
Trattnig, Siegfried [1 ,4 ,5 ]
机构
[1] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, High Field MR Ctr, Vienna, Austria
[2] Inst Measurement Sci, Dept Imaging Methods, Bratislava, Slovakia
[3] Univ Basel Hosp, Div Radiol Phys, Dept Radiol, CH-4031 Basel, Switzerland
[4] Christian Doppler Lab Clin Mol MR Imaging, Vienna, Austria
[5] Ludwig Boltzmann Inst Expt & Clin Traumatol, Austrian Cluster Tissue Regenerat, Vienna, Austria
基金
奥地利科学基金会;
关键词
T2; mapping; Cartilage; CPMG; TESS; Osteoarthritis; REPAIR TISSUE; BIOMECHANICAL PROPERTIES; KNEE OSTEOARTHRITIS; RELAXATION-TIMES; QUANTITATIVE MRI; DIFFERENTIATION; DEGENERATION; RELAXOMETRY; SEQUENCE;
D O I
10.1007/s00330-015-3979-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the clinical relevance of T-2 relaxation times, measured by 3D triple-echo steady-state (3D-TESS), in knee articular cartilage compared to conventional multi-echo spin-echo T-2-mapping. Thirteen volunteers and ten patients with focal cartilage lesions were included in this prospective study. All subjects underwent 3-Tesla MRI consisting of a multi-echo multi-slice spin-echo sequence (CPMG) as a reference method for T-2 mapping, and 3D TESS with the same geometry settings, but variable acquisition times: standard (TESSs 4:35min) and quick (TESSq 2:05min). T-2 values were compared in six different regions in the femoral and tibial cartilage using a Wilcoxon signed ranks test and the Pearson correlation coefficient (r). The local ethics committee approved this study, and all participants gave written informed consent. The mean quantitative T-2 values measured by CPMG (mean: 46 +/- 9ms) in volunteers were significantly higher compared to those measured with TESS (mean: 31 +/- 5ms) in all regions. Both methods performed similarly in patients, but CPMG provided a slightly higher difference between lesions and native cartilage (CPMG: 90ms -> 61ms [31%],p=0.0125;TESS 32ms -> 24ms [24%],p=0.0839). 3D-TESS provides results similar to those of a conventional multi-echo spin-echo sequence with many benefits, such as shortening of total acquisition time and insensitivity to B-1 and B-0 changes. aEuro cent 3D-TESS T (2) mapping provides clinically comparable results to CPMG in shorter scan-time. aEuro cent Clinical and investigational studies may benefit from high temporal resolution of 3D-TESS. aEuro cent 3D-TESS T (2) values are able to differentiate between healthy and damaged cartilage.
引用
收藏
页码:1905 / 1912
页数:8
相关论文
共 50 条
  • [1] A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage
    Vladimir Juras
    Klaus Bohndorf
    Rahel Heule
    Claudia Kronnerwetter
    Pavol Szomolanyi
    Benedikt Hager
    Oliver Bieri
    Stefan Zbyn
    Siegfried Trattnig
    European Radiology, 2016, 26 : 1905 - 1912
  • [2] T2 Mapping of Cartilage with Triple-Echo Steady State MR Sequence
    Juras, V.
    Bohndorf, K.
    Heule, R.
    Kronnerwetter, C.
    Szomolanyi, P.
    Bieri, O.
    Frollo, I.
    Trattnig, S.
    2017 11TH INTERNATIONAL CONFERENCE ON MEASUREMENT, 2017, : 189 - 192
  • [3] Fast T2 Relaxometry with an Accelerated Multi-echo Spin-echo Sequence
    Senegas, Julien
    Liu, Wei
    Dahnke, Hannes
    Song, Hotaek
    Jordan, E. Kay
    Frank, Joseph A.
    NMR IN BIOMEDICINE, 2010, 23 (08) : 958 - 967
  • [4] Fast T2 mapping using multi-echo spin-echo MRI: A linear order approach
    Fatemi, Yaghoub
    Danyali, Habibollah
    Helfroush, Mohammad Sadegh
    Amiri, Houshang
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2815 - 2830
  • [5] Exploiting multicompartment effects in triple-echo steady-state T2 mapping for fat fraction quantification
    Liu, Dian
    Steingoetter, Andreas
    Curcic, Jelena
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 423 - 429
  • [6] Multi-echo in steady-state acquisition improves MRI image quality and lumbosacral radiculopathy diagnosis efficacy compared with T2 fast spin-echo sequence
    Hu, Shuang
    Li, Yitong
    Hou, Bowen
    Zhang, Yao
    Liu, Weiyin Vivian
    Wu, Gang
    Li, Xiaoming
    NEURORADIOLOGY, 2023, 65 (05) : 969 - 977
  • [7] Multi-echo in steady-state acquisition improves MRI image quality and lumbosacral radiculopathy diagnosis efficacy compared with T2 fast spin-echo sequence
    Shuang Hu
    Yitong Li
    Bowen Hou
    Yao Zhang
    Weiyin Vivian Liu
    Gang Wu
    Xiaoming Li
    Neuroradiology, 2023, 65 : 969 - 977
  • [8] Comparison of conventional single echo and multi-echo sequences with a fast spin echo sequence for quantitative T2 mapping: Application to the prostate
    Liney, GP
    Knowles, AJ
    Manton, DJ
    Turnbull, LW
    Blackband, SJ
    Horsman, A
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 603 - 607
  • [9] A Technique for Rapid Single-Echo Spin-Echo T2 Mapping
    Sussman, Marshall S.
    Vidarsson, Logi
    Pauly, John M.
    Cheng, Hai-Ling Margaret
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) : 536 - 545
  • [10] Non-negative least squares computation for in vivo myelin mapping using simulated multi-echo spin-echo T2 decay data
    Wiggermann, V.
    Vavasour, I. M.
    Kolind, S. H.
    MacKay, A. L.
    Helms, G.
    Rauscher, A.
    NMR IN BIOMEDICINE, 2020, 33 (12)