A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage

被引:30
|
作者
Juras, Vladimir [1 ,2 ]
Bohndorf, Klaus [1 ]
Heule, Rahel [3 ]
Kronnerwetter, Claudia [1 ]
Szomolanyi, Pavol [1 ,2 ]
Hager, Benedikt [1 ]
Bieri, Oliver [3 ]
Zbyn, Stefan [1 ]
Trattnig, Siegfried [1 ,4 ,5 ]
机构
[1] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, High Field MR Ctr, Vienna, Austria
[2] Inst Measurement Sci, Dept Imaging Methods, Bratislava, Slovakia
[3] Univ Basel Hosp, Div Radiol Phys, Dept Radiol, CH-4031 Basel, Switzerland
[4] Christian Doppler Lab Clin Mol MR Imaging, Vienna, Austria
[5] Ludwig Boltzmann Inst Expt & Clin Traumatol, Austrian Cluster Tissue Regenerat, Vienna, Austria
基金
奥地利科学基金会;
关键词
T2; mapping; Cartilage; CPMG; TESS; Osteoarthritis; REPAIR TISSUE; BIOMECHANICAL PROPERTIES; KNEE OSTEOARTHRITIS; RELAXATION-TIMES; QUANTITATIVE MRI; DIFFERENTIATION; DEGENERATION; RELAXOMETRY; SEQUENCE;
D O I
10.1007/s00330-015-3979-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the clinical relevance of T-2 relaxation times, measured by 3D triple-echo steady-state (3D-TESS), in knee articular cartilage compared to conventional multi-echo spin-echo T-2-mapping. Thirteen volunteers and ten patients with focal cartilage lesions were included in this prospective study. All subjects underwent 3-Tesla MRI consisting of a multi-echo multi-slice spin-echo sequence (CPMG) as a reference method for T-2 mapping, and 3D TESS with the same geometry settings, but variable acquisition times: standard (TESSs 4:35min) and quick (TESSq 2:05min). T-2 values were compared in six different regions in the femoral and tibial cartilage using a Wilcoxon signed ranks test and the Pearson correlation coefficient (r). The local ethics committee approved this study, and all participants gave written informed consent. The mean quantitative T-2 values measured by CPMG (mean: 46 +/- 9ms) in volunteers were significantly higher compared to those measured with TESS (mean: 31 +/- 5ms) in all regions. Both methods performed similarly in patients, but CPMG provided a slightly higher difference between lesions and native cartilage (CPMG: 90ms -> 61ms [31%],p=0.0125;TESS 32ms -> 24ms [24%],p=0.0839). 3D-TESS provides results similar to those of a conventional multi-echo spin-echo sequence with many benefits, such as shortening of total acquisition time and insensitivity to B-1 and B-0 changes. aEuro cent 3D-TESS T (2) mapping provides clinically comparable results to CPMG in shorter scan-time. aEuro cent Clinical and investigational studies may benefit from high temporal resolution of 3D-TESS. aEuro cent 3D-TESS T (2) values are able to differentiate between healthy and damaged cartilage.
引用
收藏
页码:1905 / 1912
页数:8
相关论文
共 50 条
  • [31] Simple recipe for accurate T2 quantification with multi spin-echo acquisitions
    Daniel Neumann
    Martin Blaimer
    Peter M. Jakob
    Felix A. Breuer
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 567 - 577
  • [32] Dual-pathway multi-echo sequence for simultaneous frequency and T2 mapping
    Cheng, Cheng-Chieh
    Mei, Chang-Sheng
    Duryea, Jeffrey
    Chung, Hsiao-Wen
    Chao, Tzu-Cheng
    Panych, Lawrence P.
    Madore, Bruno
    JOURNAL OF MAGNETIC RESONANCE, 2016, 265 : 177 - 187
  • [33] T2 relaxometry measurements in low spatial frequency brain regions differ between fast spin-echo and multiple-echo spin-echo sequences
    Venkateswaran Rajagopalan
    Mark J. Lowe
    Erik B. Beall
    Guang H. Yue
    Erik P. Pioro
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2013, 26 : 443 - 450
  • [34] Optimal echo spacing for multi-echo imaging measurements of Bi-exponential T2 relaxation
    Dula, Adrienne N.
    Gochberg, Daniel F.
    Does, Mark D.
    JOURNAL OF MAGNETIC RESONANCE, 2009, 196 (02) : 149 - 156
  • [35] MINIMIZING ERRORS IN T2 DETERMINATIONS WITH SPIN-ECHO EQUIPMENT
    MEHLKOPF, AF
    SMIDT, J
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1966, 43 (04): : 253 - &
  • [36] VALIDATION OF LAYER SPECIFIC FEMOROTIBIAL CARTILAGE T2 RELAXATION TIME ANALYSIS BASED ON REGISTRATION OF SEGMENTED DOUBLE ECHO STEADY STATE TO MULTIPLE ECHO SPIN ECHO MRI IMAGES
    Fuerst, D.
    Eckstein, F.
    Wirth, W.
    OSTEOARTHRITIS AND CARTILAGE, 2020, 28 : S286 - S287
  • [37] Dynamic T2 mapping by multi-spin-echo spatiotemporal encoding
    Bao, Qingjia
    Ma, Lingceng
    Liberman, Gilad
    Solomon, Eddy
    Martinho, Ricardo P.
    Frydman, Lucio
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 895 - 907
  • [38] New approach to phase correction in multi-echo T2 relaxometry
    Bjork, Marcus
    Stoica, Petre
    JOURNAL OF MAGNETIC RESONANCE, 2014, 249 : 100 - 107
  • [39] T2*quantification using multi-echo gradient echo sequences: a comparative study of different readout gradients
    Shin, Seonyeong
    Yun, Seong Dae
    Shah, N. Jon
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [40] APPLICATION OF FAST SPIN-ECHO T(2)-WEIGHTED IMAGING FOR EXAMINATION OF THE NEUROCRANIUM - COMPARISON WITH THE CONVENTIONAL T(2)-WEIGHTED SPIN-ECHO SEQUENCE
    SIEWERT, C
    HOSTEN, N
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (01): : 44 - 50