A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage

被引:30
|
作者
Juras, Vladimir [1 ,2 ]
Bohndorf, Klaus [1 ]
Heule, Rahel [3 ]
Kronnerwetter, Claudia [1 ]
Szomolanyi, Pavol [1 ,2 ]
Hager, Benedikt [1 ]
Bieri, Oliver [3 ]
Zbyn, Stefan [1 ]
Trattnig, Siegfried [1 ,4 ,5 ]
机构
[1] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, High Field MR Ctr, Vienna, Austria
[2] Inst Measurement Sci, Dept Imaging Methods, Bratislava, Slovakia
[3] Univ Basel Hosp, Div Radiol Phys, Dept Radiol, CH-4031 Basel, Switzerland
[4] Christian Doppler Lab Clin Mol MR Imaging, Vienna, Austria
[5] Ludwig Boltzmann Inst Expt & Clin Traumatol, Austrian Cluster Tissue Regenerat, Vienna, Austria
基金
奥地利科学基金会;
关键词
T2; mapping; Cartilage; CPMG; TESS; Osteoarthritis; REPAIR TISSUE; BIOMECHANICAL PROPERTIES; KNEE OSTEOARTHRITIS; RELAXATION-TIMES; QUANTITATIVE MRI; DIFFERENTIATION; DEGENERATION; RELAXOMETRY; SEQUENCE;
D O I
10.1007/s00330-015-3979-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the clinical relevance of T-2 relaxation times, measured by 3D triple-echo steady-state (3D-TESS), in knee articular cartilage compared to conventional multi-echo spin-echo T-2-mapping. Thirteen volunteers and ten patients with focal cartilage lesions were included in this prospective study. All subjects underwent 3-Tesla MRI consisting of a multi-echo multi-slice spin-echo sequence (CPMG) as a reference method for T-2 mapping, and 3D TESS with the same geometry settings, but variable acquisition times: standard (TESSs 4:35min) and quick (TESSq 2:05min). T-2 values were compared in six different regions in the femoral and tibial cartilage using a Wilcoxon signed ranks test and the Pearson correlation coefficient (r). The local ethics committee approved this study, and all participants gave written informed consent. The mean quantitative T-2 values measured by CPMG (mean: 46 +/- 9ms) in volunteers were significantly higher compared to those measured with TESS (mean: 31 +/- 5ms) in all regions. Both methods performed similarly in patients, but CPMG provided a slightly higher difference between lesions and native cartilage (CPMG: 90ms -> 61ms [31%],p=0.0125;TESS 32ms -> 24ms [24%],p=0.0839). 3D-TESS provides results similar to those of a conventional multi-echo spin-echo sequence with many benefits, such as shortening of total acquisition time and insensitivity to B-1 and B-0 changes. aEuro cent 3D-TESS T (2) mapping provides clinically comparable results to CPMG in shorter scan-time. aEuro cent Clinical and investigational studies may benefit from high temporal resolution of 3D-TESS. aEuro cent 3D-TESS T (2) values are able to differentiate between healthy and damaged cartilage.
引用
收藏
页码:1905 / 1912
页数:8
相关论文
共 50 条
  • [41] T2* quantification using multi-echo gradient echo sequences: a comparative study of different readout gradients
    Seonyeong Shin
    Seong Dae Yun
    N. Jon Shah
    Scientific Reports, 13
  • [42] Technical note: Accuracy and precision of T2 and T2 with a gradient-echo spin-echo (GESE) sequence for cardiac imaging
    Huang, Qi
    Mendes, Jason
    Adluru, Ganesh
    DiBella, Edward
    MEDICAL PHYSICS, 2023, 50 (12) : 7946 - 7954
  • [43] PRIME - A MULTI-ECHO METHOD FOR MEASUREMENT OF T2' IN TRABECULAR BONE
    KANG, C
    PALEY, M
    ORDIDGE, R
    PUNWANI, S
    JOURNAL OF BONE AND MINERAL RESEARCH, 1995, 10 : S270 - S270
  • [44] IDEAL 3D spoiled gradient echo of the articular cartilage of the knee on 3.0T MRI: a comparison with conventional 3.0T fast spin-echo T2 fat saturation image
    Han, Chul Hee
    Park, Hee Jin
    Lee, So Yeon
    Chung, Eun Chul
    Choi, Seon Hyeong
    Yun, Ji Sup
    Rho, Myung Ho
    ACTA RADIOLOGICA, 2015, 56 (12) : 1479 - 1486
  • [45] Single-shot turbo spin-echo MR myelography: comparison with 3D-turbo spin-echo MR myelography and T2-turbo spin-echo at 1 T
    Karantanas, AH
    Zibis, AH
    Papanikolaou, N
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2000, 24 (01) : 37 - 42
  • [46] SINGLE SCAN SPIN-ECHO MEASUREMENTS OF T1 AND T2
    COSGROVE, T
    JOURNAL OF MAGNETIC RESONANCE, 1976, 21 (03) : 469 - 472
  • [47] A whole-brain multi-subject functional MR imaging comparison of EPI spin-echo, asymmetric spin-echo and gradient-echo sequences at 1.5 t
    Kiehl, KA
    Smith, AM
    Forster, BB
    MacKay, A
    Whittall, KP
    Liddle, PF
    RADIOLOGY, 1997, 205 : 1043 - 1043
  • [48] Comparison of single-echo T2-weighted fast spin-echo and conventional spin-echo MR sequences - In the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Banco, A
    Miraglia, R
    Nicastro, T
    Lagalla, R
    RIVISTA DI NEURORADIOLOGIA, 1998, 11 (04): : 471 - 476
  • [49] Radial fast spin-echo method for T2-weighted imaging and T2 mapping of the liver
    Altbach, MI
    Outwater, EK
    Trouard, TP
    Krupinski, EA
    Theilmann, RJ
    Stopeck, AT
    Kono, M
    Gmitro, AF
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) : 179 - 189
  • [50] Fast T2 mapping of the patellar articular cartilage with gradient and spin-echo magnetic resonance imaging at 1.5 T: validation and initial clinical experience in patients with osteoarthritis
    Quaia, Emilio
    Toffanin, Renato
    Guglielmi, Giuseppe
    Ukmar, Maja
    Rossi, Alexia
    Martinelli, Bruno
    Cova, Maria Assunta
    SKELETAL RADIOLOGY, 2008, 37 (06) : 511 - 517