Systematic error of the nose-to-nose sampling-oscilloscope calibration

被引:5
|
作者
Williams, Dylan F. [1 ]
Clement, Tracy S.
Remley, Kate A.
Hale, Tatil D.
Verbeyst, Frans
机构
[1] Natl Inst Stand & Technol, Boulder, CO 80305 USA
[2] NMDG Engn, B-2880 Bornem, Belgium
[3] Vrije Univ Brussel VIB, Fac Ingn, Vakgrp ELEC, B-1050 Brussels, Belgium
关键词
calibration; electrooptic sampling; impedance mismatch; mismatch correction; nose-to-nose calibration; sampling oscilloscope; swept-sine calibration; UNCERTAINTY; DISTORTION;
D O I
10.1109/TMTT.2007.904333
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We use traceable swept-sine and electrooptic-sampling-system-based sampling-oscilloscope calibrations to measure the systematic error of the nose-to-nose calibration, and compare the results to simulations. Our results show that the errors in the nose-to-nose calibration are small at low frequencies, but significant at high frequencies.
引用
收藏
页码:1951 / 1957
页数:7
相关论文
共 50 条
  • [31] 用于宽带取样示波器的Nose-to-nose校准技术
    朱江淼
    刘明亮
    陈建新
    应用基础与工程科学学报, 2003, (01) : 94 - 97
  • [32] Experimental inoculation and nose-to-nose transmission of Clostridioides difficile between weaned piglets
    Boarini-Ferroni, Livia
    Cardozo, Marita Vedovelli
    Casagrande, Mariana Froner
    Nascimento, Karla Alvarenga
    de Souza Almeida, Henrique Meiroz
    Mechler-Dreibi, Marina Lopes
    de Oliveira, Luis Guilherme
    Schocken-Iturrino, Ruben Pablo
    VETERINARY MICROBIOLOGY, 2020, 247
  • [33] DIGITAL-COMPUTER PROCESSING OF SAMPLING-OSCILLOSCOPE DATA
    COHN, CE
    NUCLEAR INSTRUMENTS & METHODS, 1969, 71 (03): : 349 - &
  • [34] 宽带取样示波器Nose-to-Nose校正理论的新进展
    林茂六
    赵华
    电子学报, 2001, (03) : 409 - 411
  • [35] 取样示波器nose-to-nose校准技术中kick-out脉冲的研究
    朱江淼
    刘明亮
    高昀
    中国计量学院学报, 2003, (03) : 23 - 26
  • [36] Calibration of Sample-Time Error in a Sampling Oscilloscope and Uncertainty Analysis
    Cho, Chihyun
    Lee, Joo-Gwang
    Kang, Tae-Weon
    Kang, No-Weon
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [37] A nose-to-nose comparison of the physiological and molecular responses of rainbow trout to high environmental ammonia in seawater versus freshwater
    Wood, Chris M.
    Nawata, C. Michele
    JOURNAL OF EXPERIMENTAL BIOLOGY, 2011, 214 (21): : 3557 - 3569
  • [38] The effect of offset voltage on the kick-out pulses used in the nose-to-nose sampler impulse response characterization method
    Larson, DR
    Paulter, NG
    IMTC/2000: PROCEEDINGS OF THE 17TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE: SMART CONNECTIVITY: INTEGRATING MEASUREMENT AND CONTROL, 2000, : 1425 - 1428
  • [39] Sampling-oscilloscope measurement of a microwave mixer with single-digrit phase accuracy
    Williams, DF
    Khenissi, H
    Ndagijimana, F
    Remley, KA
    Dunsmore, JP
    Hale, PD
    Wang, JCA
    Clement, TS
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2006, 54 (03) : 1210 - 1217
  • [40] The posterior intralaminar thalamic nucleus promotes nose-to-nose contacts leading to prosocial reception in the sequence of mouse social interaction
    Arakawa, Hiroyuki
    Tokashiki, Mana
    EUROPEAN JOURNAL OF NEUROSCIENCE, 2024, 60 (07) : 5731 - 5749