Feasibility of underwater radiation detector using a silicon photomultiplier (SiPM)

被引:2
|
作者
Kim, Jeong Ho [1 ]
Joo, Koan Sik [2 ]
机构
[1] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South Korea
[2] Univ Myongji, Dept Phys, Yongin, South Korea
关键词
Detector design and construction technologies and materials; Dosimetry concepts and apparatus; Scintillators and scintillating fibres and light guides; COMPACT;
D O I
10.1088/1748-0221/15/04/P04013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, the development of an underwater radiation detector is presented using a silicon photomultiplier (SiPM), CsI(Tl) scintillator, and light guide. The detector characteristics were evaluated. The detector has good energy resolution characteristics in which the gammaray emission energy 122 keV of Co-57 had an energy resolution of 18.12%, 356 keV of the Ba-133 spectrum had 10.91%, 662 keV of the Cs-137 spectrum had 8.84%, and 1332 keV of the of the Co-60 spectrum had 4.55%. Further, in the case of mixed sources, the gamma radiation peaks were readily distinguishable, and the R-squared value in the gamma-ray energy of 122-1332 keV for energy linearity was calculated to be 0.99937, demonstrating an exceptional energy linearity. In addition, radiative contaminated water was prepared as a liquid radiation source and characterized. The measurement results showed 0.61 +/- 0.0046 cps in the background and 0.74 +/- 0.0070 cps at the minimum concentration of 38.71 Bq/L. The R-squared value for concentrations in the range of 38.71-4955 Bq/L, which indicates the linearity of a detector based on the signal intensity, was determined to be 0.99710, indicating a good linear responsivity. The characterization results suggest that the radiation detectors based on SiPM- and CsI(Tl) can replace the currently used PMT-based radiation detector in an underwater environment.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Study of timing performance of silicon photomultiplier and application for a Cherenkov detector
    Ahmed, G. S. M.
    Buehler, P.
    Marton, J.
    Suzuki, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01): : 393 - 397
  • [42] Performance evaluation of an MR-compatible silicon photomultiplier (SiPM) small animal PET insert
    Kwon, Sun Il
    Ito, Mikiko
    Lee, Chan Mi
    Ko, Guen Bae
    Yoon, Hyun Suk
    Kim, Joong Hyun
    Song, In Chan
    Lee, Dong Soo
    Hong, Seong Jong
    Lee, Jae Sung
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [43] G4SiPM: A novel silicon photomultiplier simulation package for Geant4
    Niggemann, Tim
    Dietz-Laursonn, Erik
    Hebbeker, Thomas
    Kuensken, Andreas
    Lauscher, Markus
    Merschmeyer, Markus
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 : 344 - 347
  • [44] Calibration and performances of a multichannel DAQ system for Silicon Photomultiplier (SiPM) matrices in PET applications.
    Marcatili, Sara
    Bisogni, Maria G.
    Collazuol, Gianmaria
    Llosa, Gabriela
    Magazzti, Guido
    Morsani, Fabio
    Del Guerra, Alberto
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2319 - +
  • [45] Measurement setup and procedure for the accurate determination of the gain and the breakdown voltage for Silicon Photomultiplier (SiPM) Arrays
    Popescu, Florin-Adrian
    Chiritoi, Gabriel
    Popescu, Eugeniu Mihnea
    2021 INTERNATIONAL SEMICONDUCTOR CONFERENCE (CAS), 2021, : 275 - 278
  • [46] Signal encoding method for a time-of-flight PET detector using a silicon photomultiplier array
    Kwon, Sun Il
    Lee, Jae Sung
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 761 : 39 - 45
  • [47] A Depth-of-interaction PET Detector Using Mutual Gain-equalized Silicon Photomultiplier
    Xi, W.
    Weisenberger, A. G.
    Dong, H.
    Kross, B.
    Lee, S.
    McKisson, J.
    McKisson, J. E.
    Zorn, C.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3166 - 3168
  • [48] High Data-Rate Neutron-Sensitive Pixelated Detector Using Silicon Photomultiplier
    Chong, Su-Ann
    Riedel, Richard
    Visscher, Theodore
    Dohanue, Cornelius, Jr.
    Hannan, Bruce
    Montcalm, Christopher
    Hayward, Jason
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [49] Development of Small-Animal PET Prototype Using Silicon Photomultiplier (SiPM): Initial Results of Phantom and Animal Imaging Studies
    Kwon, Sun Il
    Lee, Jae Sung
    Yoon, Hyun Suk
    Ito, Mikiko
    Ko, Guen Bae
    Choi, Jae Yeon
    Lee, Sung-Hyuk
    Song, In Chan
    Jeong, Jae Min
    Lee, Dong Soo
    Hong, Seong Jong
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (04) : 572 - 579
  • [50] Sparse Detector Configuration in SiPM Digital Photon Counting PET: a Feasibility Study
    Zhang, Jun
    Knopp, Michelle I.
    Knopp, Michael V.
    MOLECULAR IMAGING AND BIOLOGY, 2019, 21 (03) : 447 - 453