Sparse Detector Configuration in SiPM Digital Photon Counting PET: a Feasibility Study

被引:28
|
作者
Zhang, Jun [1 ]
Knopp, Michelle I. [1 ]
Knopp, Michael V. [1 ]
机构
[1] Ohio State Univ, Wexner Med Ctr, Dept Radiol, Wright Ctr Innovat Biomed Imaging, 395 W 12th Ave,Room 430, Columbus, OH 43210 USA
关键词
Digital photon counting; Sparse-ring PET; Silicon photomultiplier; Solid state; 2-deoxy-2-[F-18]fluoro-D-glucose; Whole-body PET; TIME-OF-FLIGHT; PROTOTYPE;
D O I
10.1007/s11307-018-1250-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo investigate the minimum number of SiPM detectors required for solid-state digital photon counting (DPC) oncologic whole-body 2-deoxy-2-[F-18]fluoro-D-glucose ([F-18]FDG) positron emission tomography (PET)/X-ray computed tomography (CT).ProceduresA DPC PET/CT (Vereos, Philips) with 23,040 1-to-1 crystal-to-detector couplings was utilized. [F-18]FDG PET/CT of a uniformity phantom and 10 oncology patients selected by block randomization from a large clinical trial were included (45738MBq, 6422min p.i, body mass index (BMI) of 14-41). Sparse-ring PET configurations with 50% detector reduction in tangential and axial directions were analyzed and compared to the current full ring configuration. Resulting images were reviewed blindly and quantitatively over detectable lesions and the liver.Results One hundred twelve lesions (d=10 to 95mm) were analyzed in the patient population. All lesions remained visible and were demonstrated without compromised image quality under all BMIs in the 50% sparse detector configurations despite the DPC PET system sensitivity reduction to 1/4th. An excellent consistency of SUVmax measurements of lesions with an average of 5% SUVmax difference was found between dPET of full and sparse configurations.Conclusions The feasibility of either expanding the axial field of view (FOV) by a factor of two or halving the number of detectors was demonstrated for solid-state digital photon counting PET, thus either potentially enabling cost reduction or extended effective axial FOV without increased cost.
引用
收藏
页码:447 / 453
页数:7
相关论文
共 50 条
  • [1] Sparse Detector Configuration in SiPM Digital Photon Counting PET: a Feasibility Study
    Jun Zhang
    Michelle I. Knopp
    Michael V. Knopp
    Molecular Imaging and Biology, 2019, 21 : 447 - 453
  • [2] SiPM based photon counting detector for scanning digital radiography
    Babichev, E. A.
    Baru, S. E.
    Grigoriev, D. N.
    Oleynikov, V. P.
    Porosev, V. V.
    Savinov, G. A.
    Callier, Stephane
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [3] The SiPM - A new photon detector for PET
    Otte, N
    Dolgoshein, B
    Hose, J
    Klemin, S
    Lorenz, E
    Mirzoyan, R
    Popova, E
    Teshima, M
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 150 : 417 - 420
  • [4] Feasibility of Performing Clinical Low Dose and Fast Brain PET Imaging Enabled by SiPM Digital Photon Counting PET/CT
    Zhang, Jun
    Lustberg, Maryam
    Binzel, Katherine
    Hsieh, Yu-Lung
    Friel, Michael
    Porter, Taylor
    Magyer, Melissa
    Moore, Richard
    Knopp, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [5] Feasibility study of photon-counting CT for material identification based on YSO/SiPM detector: A proof of concept
    Zhang, Du
    Wu, Bin
    Xi, Daoming
    Chen, Rui
    Xiao, Peng
    Xie, Qingguo
    MEDICAL PHYSICS, 2024, 51 (11) : 8151 - 8167
  • [6] The MINDView brain PET detector, feasibility study based on SiPM arrays
    Gonzalez, Antonio J.
    Majewski, Stan
    Sanchez, Filomeno
    Aussenhofer, Sebastian
    Aguilar, Albert
    Conde, Pablo
    Hernandez, Liczandro
    Vidal, Luis E.
    Pani, Roberto
    Bettiol, Marco
    Fabbri, Andrea
    Bert, Julien
    Visvikis, Dimitris
    Jackson, Carl
    Murphy, John
    O'Neill, Kevin
    Benlloch, Jose M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 818 : 82 - 90
  • [7] Feasibility study of sparse-angular sampling and sinogram interpolation in material decomposition with a photon-counting detector
    Kim, Dohyeon
    Jo, Byungdu
    Park, Su-Jin
    Kim, Hyemi
    Kim, Hee-Joung
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [8] Effect of next generation SiPM digital photon counting PET technology on effective system spatial resolution
    Zhang, Jun
    Maniawski, Piotr
    Knopp, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [9] A prototype detector module for combined PET/CT or combined photon counting/standard CT based on SiPM technology
    Persson, Andreas
    Khaplanov, Anton
    Cederwall, Bo
    Bohm, Christian
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3503 - +
  • [10] Performance evaluation of a PET detector with a sparse SiPM array and gap reflectors
    Wei Q.
    Wang F.
    Xu T.
    Jia C.
    Jiang N.
    Gu Y.
    Ma T.
    Liu Y.
    2018, Tsinghua University (58): : 929 - 933