Feasibility of underwater radiation detector using a silicon photomultiplier (SiPM)

被引:2
|
作者
Kim, Jeong Ho [1 ]
Joo, Koan Sik [2 ]
机构
[1] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South Korea
[2] Univ Myongji, Dept Phys, Yongin, South Korea
关键词
Detector design and construction technologies and materials; Dosimetry concepts and apparatus; Scintillators and scintillating fibres and light guides; COMPACT;
D O I
10.1088/1748-0221/15/04/P04013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, the development of an underwater radiation detector is presented using a silicon photomultiplier (SiPM), CsI(Tl) scintillator, and light guide. The detector characteristics were evaluated. The detector has good energy resolution characteristics in which the gammaray emission energy 122 keV of Co-57 had an energy resolution of 18.12%, 356 keV of the Ba-133 spectrum had 10.91%, 662 keV of the Cs-137 spectrum had 8.84%, and 1332 keV of the of the Co-60 spectrum had 4.55%. Further, in the case of mixed sources, the gamma radiation peaks were readily distinguishable, and the R-squared value in the gamma-ray energy of 122-1332 keV for energy linearity was calculated to be 0.99937, demonstrating an exceptional energy linearity. In addition, radiative contaminated water was prepared as a liquid radiation source and characterized. The measurement results showed 0.61 +/- 0.0046 cps in the background and 0.74 +/- 0.0070 cps at the minimum concentration of 38.71 Bq/L. The R-squared value for concentrations in the range of 38.71-4955 Bq/L, which indicates the linearity of a detector based on the signal intensity, was determined to be 0.99710, indicating a good linear responsivity. The characterization results suggest that the radiation detectors based on SiPM- and CsI(Tl) can replace the currently used PMT-based radiation detector in an underwater environment.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Fast photomultiplier tube gating system for underwater laser detector
    Lei, Xuanhua
    Yang, Kecheng
    Rao, Jionghui
    Zhang, Xiaohui
    Xia, Min
    Zheng, Yi
    Li, Wei
    27TH INTERNATIONAL CONGRESS ON HIGH SPEED PHOTOGRAPHY AND PHOTONICS, PRTS 1-3, 2007, 6279
  • [22] Feasibility of SiPM and CsI(Tl) based radiation detector with light guide for measurement of radioactivation in a linear accelerator
    Kim, Jeongho
    Park, Byungdo
    JOURNAL OF INSTRUMENTATION, 2023, 18 (09):
  • [23] Silicon photomultiplier based photon detector module as a detector of Cherenkov photons
    Korpar, Samo
    Chagani, Hassan
    Dolenec, Rok
    Krizan, Peter
    Pestotnik, Rok
    Stanovnik, Ales
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01): : 333 - 335
  • [24] Cryogenic Temperatures Characterization of an MAPbBr3 Perovskite and a Silicon Photomultiplier for Radiation Detector Applications
    Jegal, Jin
    Kim, Hongjoo
    Park, HyeoungWoo
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2023, 260 (05):
  • [25] Silicon photomultiplier as a position sensitive detector of Cherenkov photons
    Pestotnik, R.
    Dolenec, R.
    Korpar, S.
    Krizan, P.
    Petelin, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 457 - 460
  • [26] Energy and Time Characterization of Silicon Photomultiplier Detector Blocks
    Sanjani, Sahinaz Safari
    Taghibakhsh, Farhad
    Levin, Craig S.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3045 - 3047
  • [27] A FEASIBILITY STUDY TO TRACK COSMIC MUONS USING A DETECTOR WITH SIPM DEVICES BASED ON AMPLITUDE DISCRIMINATION
    Stanca, D.
    Niculescu-Oglinzanu, M.
    Brancus, I.
    Mitrica, B.
    Balaceanu, A.
    Cautisanu, B.
    Gherghel-Lascu, A.
    Haungs, A.
    Mathes, H. -J.
    Rebels, H.
    Saftoiu, A.
    Sima, O.
    Mosu, T.
    Alionte, T.
    Alkotbe, B.
    Stoian, D.
    ROMANIAN REPORTS IN PHYSICS, 2017, 69 (02)
  • [28] Proof of feasibility of the Vacuum Silicon PhotoMultiplier Tube (VSiPMT)
    Barbarino, G.
    Campajola, L.
    de Asmundis, R.
    De Rosa, G.
    Fiorillo, G.
    Migliozzi, P.
    Barbato, F. C. T.
    Mollo, C. M.
    Russo, A.
    Vivolo, D.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [29] The Vacuum Silicon Photomultiplier Tube (VSiPMT): a New Concept of Photon Detector. First Feasibility Results.
    Russo, Stefano
    Barbarino, Giancarlo
    de Asmundis, Riccardo
    De Rosa, Gianfranca
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1966 - +
  • [30] Modelling a silicon photomultiplier (SiPM) as a signal source for optimum front-end design
    Corsi, F.
    Dragone, A.
    Marzocca, C.
    Del Guerra, A.
    Delizia, P.
    Dinu, N.
    Piemonte, C.
    Boscardin, M.
    Dalla Betta, G. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01): : 416 - 418