Direct DC Voltages Comparison between two Programmable Josephson Voltage Standards at SCL

被引:0
|
作者
Yang, S. [1 ]
Cular, S. [2 ,3 ]
Rufenacht, A. [2 ,3 ]
Burroughs, C. J. [2 ,3 ]
Dresselhaus, P. D. [2 ,3 ]
Benz, S. P. [2 ,3 ]
Ng, M. N. [1 ]
机构
[1] Stand & Calibrat Lab, Hong Kong, Peoples R China
[2] NIST, Gaithersburg, MD 20899 USA
[3] NIST, Boulder, CO 80305 USA
来源
2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM) | 2020年
关键词
Programmable Josephson voltage standard; quantum voltage measurement; measurement uncertainty; Josephson voltage comparison;
D O I
10.1109/cpem49742.2020.9191745
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Standards and Calibration Laboratory (SCL) setup in 2018 a liquid helium based programmable Josephson voltage standard (PJVS) developed by the National Institute of Standards and Technology (NIST). The system was validated by direct comparison with a NIST transportable PJVS system at 1.018 V, 4 V, 6 V, 8 V and 10 V. The difference between the systems was within 0.5 nV, with an expanded uncertainty of less than 2.2 nV (k = 2). In this paper, the setup and the results of the direct comparison method are presented.
引用
收藏
页数:2
相关论文
共 50 条
  • [41] Precision sampling measurements using ac programmable Josephson voltage standards
    Rufenacht, A.
    Burroughs, C. J.
    Benz, S. P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (04):
  • [42] 10 VSINIS Josephson junction series arrays for programmable voltage standards
    Kohlmann, J
    Schulze, H
    Behr, R
    Müller, F
    Niemeyer, J
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) : 192 - 194
  • [43] Automated Leakage Current Measurement Capability for Programmable Josephson Voltage Standards
    Burroughs, Charles J.
    Rilfenacht, Alain
    Cular, Stefan
    Dresselhaus, Paul D.
    2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,
  • [44] Method for Ensuring Accurate AC Waveforms With Programmable Josephson Voltage Standards
    Burroughs, Charles J., Jr.
    Ruefenacht, Alain
    Benz, Samuel P.
    Dresselhaus, Paul D.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (06) : 1627 - 1633
  • [45] Direct Comparison of a Pulse-driven Josephson Arbitrary Waveform Synthesizer and a Programmable Josephson Voltage Standard at 1 Volt
    Rufenacht, Alain
    Flowers-Jacobs, Nathan E.
    Fox, Anna E.
    Burroughs, Charles J.
    Dresselhaus, Paul D.
    Benz, Samuel P.
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [46] Interlaboratory comparison of Josephson voltage standards between NIST and Lockheed Martin Astronautics
    Tang, YH
    Miller, WB
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) : 210 - 213
  • [47] High precision comparison between a programmable and a pulse-driven Josephson voltage standard
    Jeanneret, Blaise
    Ruefenacht, Alain
    Overney, Frederic
    van den Brom, Helko
    Houtzager, Ernest
    METROLOGIA, 2011, 48 (05) : 311 - 316
  • [48] STABLE JOSEPHSON REFERENCE VOLTAGES BETWEEN 0.1 AND 1.3V FOR HIGH-PRECISION VOLTAGE STANDARDS
    NIEMEYER, J
    GRIMM, L
    MEIER, W
    HINKEN, JH
    VOLLMER, E
    APPLIED PHYSICS LETTERS, 1985, 47 (11) : 1222 - 1223
  • [49] Programmable Josephson Voltage Standards Comparisons at 10 V-DC, 1 V and 7 V RMS, 50 Hz between BIPM and CENAM
    Aviles, David
    Solve, Stephane
    Medina, Jesus
    Chayramy, Regis
    Navarrete, Enrique
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [50] Comparison of Josephson array voltage standards using Zener reference standards
    Gengru, Z
    Yifei, H
    Lu, W
    Guifen, Z
    Jensen, HD
    Henderson, LCA
    Thompson, RP
    METROLOGIA, 1997, 34 (05) : 423 - 425