Attenuation Correction for Fixed MR Components in a Simultaneous PET/MR System

被引:0
|
作者
Xie, Huifang [1 ]
Zhao, Jun [1 ]
Dong, Yun [2 ]
Lv, Yang [2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai, Peoples R China
[2] Shanghai United Imaging Healthcare Co Ltd, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
SEGMENTATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Attenuation correction for fixed MR components like MR table and coils in a simultaneous positron emission tomography and magnetic resonance (PET/MR) system is mandatory for accurate quantification of activity distribution. Conventional methods to derive the attenuation maps of MR table and coils include CT scan and transmission scan. Both methods have their advantages and disadvantages. CT scan method is straightforward, however, the images obtained from CT scan have severe metal artifacts due to wires and circuits, and the attenuation coefficients transformation from X-ray energy to Gamma ray energy needs to be remodeled. Transmission scan method avoids the transformation between different energy levels but needs an extra setup of a rotating rod source (usually (68)Gc) and its resolution is poor. In this work, we aim to combine the merits of these two methods. Instead of complex rotating rod source device, a Ge-68 cylinder source was placed at the center of field of view (FOV) as a stationary emission source. By doing so, the full scan reconstruction problem turned to he a limited angle reconstruction problem. Modified maximum likelihood expectation-maximization (MLEM) algorithm incorporated with Split Bregman algorithm was employed to reconstruct the attenuation map directly from the emission data. An additional CT scan provided the structure information of the MR table and coils, which was used as prior knowledge to confine the region of attenuation coefficients. The proposed method was validated by simulations and real data acquired with a simultaneous PET/MR system.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] MR-based attenuation correction for whole-body PET-MR
    Ouyang, Jinsong
    Chun, Se Young
    Brady, Thomas
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [42] MR-based attenuation correction for whole-body PET-MR
    Ouyang, Jinsong
    Chun, Se Young
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [43] Errors in MR-based attenuation correction for brain imaging with PET/MR scanners
    Kops, Elena Rota
    Herzog, Hans
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 104 - 107
  • [44] Investigation of MR-Based Attenuation Correction and Motion Compensation for Hybrid PET/MR
    Buerger, Christian
    Tsoumpas, Charalampos
    Aitken, Andrew
    King, Andrew Peter
    Schleyer, Paul
    Schulz, Volkmar
    Marsden, Paul K.
    Schaeffter, Tobias
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1967 - 1976
  • [45] A hybrid method for generation of attenuation map for MR-based attenuation correction of PET data in prostate PET/MR imaging
    Mehdi Shirin Shandiz
    Mohammad Hadi Arabi
    Pardis Ghafarian
    Mehrdad Bakhshayesh Karam
    Hamidreza Saligheh Rad
    Mohammad Reza Ay
    EJNMMI Physics, 1 (Suppl 1)
  • [46] Template based Attenuation Correction for PET in MR-PET Scanners
    Kops, Elena Rota
    Herzog, Hans
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3061 - 3064
  • [47] A Novel Approach for the Attenuation Correction of PET Data in PET/MR Systems
    Chang, T.
    Clark, J.
    Mawlawi, O.
    MEDICAL PHYSICS, 2012, 39 (06) : 3644 - 3644
  • [48] Preclinical Evaluation of MR Attenuation Correction Versus CT Attenuation Correction on a Sequential Whole-Body MR/PET Scanner
    Bini, Jason
    Izquierdo-Garcia, David
    Mateo, Jesus
    Machac, Josef
    Narula, Jagat
    Fuster, Valentin
    Fayad, Zahi A.
    INVESTIGATIVE RADIOLOGY, 2013, 48 (05) : 313 - 322
  • [49] Simultaneous carotid PET/MR: feasibility and improvement of magnetic resonance-based attenuation correction
    Bini, Jason
    Eldib, Mootaz
    Robson, Philip M.
    Calcagno, Claudia
    Fayad, Zahi A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (01): : 61 - 71
  • [50] Simultaneous carotid PET/MR: feasibility and improvement of magnetic resonance-based attenuation correction
    Jason Bini
    Mootaz Eldib
    Philip M. Robson
    Claudia Calcagno
    Zahi A. Fayad
    The International Journal of Cardiovascular Imaging, 2016, 32 : 61 - 71