Errors in MR-based attenuation correction for brain imaging with PET/MR scanners

被引:2
|
作者
Kops, Elena Rota [1 ]
Herzog, Hans [1 ]
机构
[1] Forschungszentrum Juelich, INM4, Julich, Germany
关键词
MR/PET; Template-based attenuation correction; Errors;
D O I
10.1016/j.nima.2012.09.032
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Aim: Attenuation correction of PET data acquired by hybrid MR/PET scanners remains a challenge, even if several methods for brain and whole-body measurements have been developed recently. A template-based attenuation correction for brain imaging proposed by our group is easy to handle and delivers reliable attenuation maps in a short time. However, some potential error sources are analyzed in this study. We investigated the choice of template reference head among all the available data (error A), and possible skull anomalies of the specific patient, such as discontinuities due to surgery (error B). Materials and methods: An anatomical MR measurement and a 2-bed-position transmission scan covering the whole head and neck region were performed in eight normal subjects (4 females, 4 males). Error A: Taking alternatively one of the eight heads as reference, eight different templates were created by nonlinearly registering the images to the reference and calculating the average. Eight patients (4 females, 4 males; 4 with brain lesions, 4 w/o brain lesions) were measured in the Siemens BrainPET/MR scanner. The eight templates were used to generate the patients' attenuation maps required for reconstruction. ROI and VOI atlas-based comparisons were performed employing all the reconstructed images. Error B: CT-based attenuation maps of two volunteers were manipulated by manually inserting several skull lesions and filling a nasal cavity. The corresponding attenuation coefficients were substituted with the water's coefficient (0.096/cm). Results: Error A: The mean SUVs over the eight templates pairs for all eight patients and all VOIs did not differ significantly one from each other. Standard deviations up to 1.24% were found. Error B: After reconstruction of the volunteers' BrainPET data with the CT-based attenuation maps without and with skull anomalies, a VOI-atlas analysis was performed revealing very little influence of the skull lesions (less than 3%), while the filled nasal cavity yielded an overestimation in cerebellum up to 5%. Conclusions: The present error analysis confirms that our template-based attenuation method provides reliable attenuation corrections of PET brain imaging measured in PET/MR scanners. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 107
页数:4
相关论文
共 50 条
  • [1] Possible errors with MR-based attenuation correction for brain imaging in PET/MR scanners
    Kops, Elena Rota
    Herzog, Hans
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [2] MR-Based PET Attenuation Correction for PET/MR Imaging
    Bezrukov, Ilja
    Mantlik, Frederic
    Schmidt, Holger
    Schoelkopf, Bernhard
    Pichler, Bernd J.
    SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) : 45 - 59
  • [3] Optimization Of MR-Based Attenuation Correction For Cardiac PET/MR
    Vergani, V.
    Robson, P.
    Trivieri, M.
    Fayad, Z. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S699 - S700
  • [4] MR-based attenuation correction in brain PET based on UTE sequences
    Jorge Cabello
    Stephan G Nekolla
    Sibylle I Ziegler
    EJNMMI Physics, 1 (Suppl 1)
  • [5] Template based attenuation correction for brain MR-PET scanners
    Kops, E. Rota
    Herzog, H.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 : S337 - S337
  • [6] A hybrid method for generation of attenuation map for MR-based attenuation correction of PET data in prostate PET/MR imaging
    Mehdi Shirin Shandiz
    Mohammad Hadi Arabi
    Pardis Ghafarian
    Mehrdad Bakhshayesh Karam
    Hamidreza Saligheh Rad
    Mohammad Reza Ay
    EJNMMI Physics, 1 (Suppl 1)
  • [7] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    David Izquierdo-Garcia
    Stephen J. Sawiak
    Karin Knesaurek
    Jagat Narula
    Valentin Fuster
    Joseph Machac
    Zahi A. Fayad
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1574 - 1584
  • [8] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    Izquierdo-Garcia, David
    Sawiak, Stephen J.
    Knesaurek, Karin
    Narula, Jagat
    Fuster, Valentin
    Machac, Joseph
    Fayad, Zahi A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (08) : 1574 - 1584
  • [9] Simultaneous PET/MR imaging: MR-based attenuation correction of local radiofrequency surface coils
    Paulus, Daniel H.
    Braun, Harald
    Aklan, Bassim
    Quick, Harald H.
    MEDICAL PHYSICS, 2012, 39 (07) : 4306 - 4315
  • [10] MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data
    Thomas Beyer
    Markus Weigert
    Harald H. Quick
    Uwe Pietrzyk
    Florian Vogt
    Christoph Palm
    Gerald Antoch
    Stefan P. Müller
    Andreas Bockisch
    European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35 : 1142 - 1146