Errors in MR-based attenuation correction for brain imaging with PET/MR scanners

被引:2
|
作者
Kops, Elena Rota [1 ]
Herzog, Hans [1 ]
机构
[1] Forschungszentrum Juelich, INM4, Julich, Germany
关键词
MR/PET; Template-based attenuation correction; Errors;
D O I
10.1016/j.nima.2012.09.032
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Aim: Attenuation correction of PET data acquired by hybrid MR/PET scanners remains a challenge, even if several methods for brain and whole-body measurements have been developed recently. A template-based attenuation correction for brain imaging proposed by our group is easy to handle and delivers reliable attenuation maps in a short time. However, some potential error sources are analyzed in this study. We investigated the choice of template reference head among all the available data (error A), and possible skull anomalies of the specific patient, such as discontinuities due to surgery (error B). Materials and methods: An anatomical MR measurement and a 2-bed-position transmission scan covering the whole head and neck region were performed in eight normal subjects (4 females, 4 males). Error A: Taking alternatively one of the eight heads as reference, eight different templates were created by nonlinearly registering the images to the reference and calculating the average. Eight patients (4 females, 4 males; 4 with brain lesions, 4 w/o brain lesions) were measured in the Siemens BrainPET/MR scanner. The eight templates were used to generate the patients' attenuation maps required for reconstruction. ROI and VOI atlas-based comparisons were performed employing all the reconstructed images. Error B: CT-based attenuation maps of two volunteers were manipulated by manually inserting several skull lesions and filling a nasal cavity. The corresponding attenuation coefficients were substituted with the water's coefficient (0.096/cm). Results: Error A: The mean SUVs over the eight templates pairs for all eight patients and all VOIs did not differ significantly one from each other. Standard deviations up to 1.24% were found. Error B: After reconstruction of the volunteers' BrainPET data with the CT-based attenuation maps without and with skull anomalies, a VOI-atlas analysis was performed revealing very little influence of the skull lesions (less than 3%), while the filled nasal cavity yielded an overestimation in cerebellum up to 5%. Conclusions: The present error analysis confirms that our template-based attenuation method provides reliable attenuation corrections of PET brain imaging measured in PET/MR scanners. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 107
页数:4
相关论文
共 50 条
  • [21] Investigation of MR-Based Attenuation Correction and Motion Compensation for Hybrid PET/MR
    Buerger, Christian
    Tsoumpas, Charalampos
    Aitken, Andrew
    King, Andrew Peter
    Schleyer, Paul
    Schulz, Volkmar
    Marsden, Paul K.
    Schaeffter, Tobias
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1967 - 1976
  • [22] MR-based attenuation correction for whole-body PET-MR
    Ouyang, Jinsong
    Chun, Se Young
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [23] MR-based attenuation correction for whole-body PET-MR
    Ouyang, Jinsong
    Chun, Se Young
    Brady, Thomas
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [24] Validations for MR-based partial volume correction for brain PET imaging
    Matsubara, Keisuke
    Ibaraki, Masanobu
    Maeda, Tetsuya
    Kinoshita, Toshibumi
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [25] Quantitative PET/MR imaging of lung cancer in the presence of artifacts in the MR-based attenuation correction maps
    Kuttner, Samuel
    Lassen, Martin Lyngby
    Oen, Silje Kjaernes
    Sundset, Rune
    Beyer, Thomas
    Eikenes, Live
    ACTA RADIOLOGICA, 2020, 61 (01) : 11 - 20
  • [26] Accurate hybrid template–based and MR-based attenuation correction using UTE images for simultaneous PET/MR brain imaging applications
    Jakub Baran
    Zhaolin Chen
    Francesco Sforazzini
    Nicholas Ferris
    Sharna Jamadar
    Ben Schmitt
    David Faul
    Nadim Jon Shah
    Marian Cholewa
    Gary F. Egan
    BMC Medical Imaging, 18
  • [27] Template based Attenuation Correction for PET in MR-PET Scanners
    Kops, Elena Rota
    Herzog, Hans
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3061 - 3064
  • [28] Comparison of Image Quality According to Phantom Fluid Material in MR-based Attenuation Correction PET Imaging in PET/MR
    Park, Chan Rok
    JOURNAL OF MAGNETICS, 2021, 26 (03) : 299 - 304
  • [29] Impact of MR-Based Attenuation Correction on Neurologic PET Studies
    Su, Yi
    Rubin, Brian B.
    McConathy, Jonathan
    Laforest, Richard
    Qi, Jing
    Sharma, Akash
    Priatna, Agus
    Benzinger, Tammie L. S.
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (06) : 913 - 917
  • [30] A comparison of MR-based attenuation correction in PET versus SPECT
    Marshall, H. R.
    Stodilka, R. Z.
    Theberge, J.
    Sabondjian, E.
    Legros, A.
    Deans, L.
    Sykes, J. M.
    Thompson, R. T.
    Prato, F. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14): : 4613 - 4629