Errors in MR-based attenuation correction for brain imaging with PET/MR scanners

被引:2
|
作者
Kops, Elena Rota [1 ]
Herzog, Hans [1 ]
机构
[1] Forschungszentrum Juelich, INM4, Julich, Germany
关键词
MR/PET; Template-based attenuation correction; Errors;
D O I
10.1016/j.nima.2012.09.032
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Aim: Attenuation correction of PET data acquired by hybrid MR/PET scanners remains a challenge, even if several methods for brain and whole-body measurements have been developed recently. A template-based attenuation correction for brain imaging proposed by our group is easy to handle and delivers reliable attenuation maps in a short time. However, some potential error sources are analyzed in this study. We investigated the choice of template reference head among all the available data (error A), and possible skull anomalies of the specific patient, such as discontinuities due to surgery (error B). Materials and methods: An anatomical MR measurement and a 2-bed-position transmission scan covering the whole head and neck region were performed in eight normal subjects (4 females, 4 males). Error A: Taking alternatively one of the eight heads as reference, eight different templates were created by nonlinearly registering the images to the reference and calculating the average. Eight patients (4 females, 4 males; 4 with brain lesions, 4 w/o brain lesions) were measured in the Siemens BrainPET/MR scanner. The eight templates were used to generate the patients' attenuation maps required for reconstruction. ROI and VOI atlas-based comparisons were performed employing all the reconstructed images. Error B: CT-based attenuation maps of two volunteers were manipulated by manually inserting several skull lesions and filling a nasal cavity. The corresponding attenuation coefficients were substituted with the water's coefficient (0.096/cm). Results: Error A: The mean SUVs over the eight templates pairs for all eight patients and all VOIs did not differ significantly one from each other. Standard deviations up to 1.24% were found. Error B: After reconstruction of the volunteers' BrainPET data with the CT-based attenuation maps without and with skull anomalies, a VOI-atlas analysis was performed revealing very little influence of the skull lesions (less than 3%), while the filled nasal cavity yielded an overestimation in cerebellum up to 5%. Conclusions: The present error analysis confirms that our template-based attenuation method provides reliable attenuation corrections of PET brain imaging measured in PET/MR scanners. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 107
页数:4
相关论文
共 50 条
  • [41] MR-based truncation correction using an advanced HUGE method to improve attenuation correction in PET/MR imaging of obese patients
    Lindemann, Maike E.
    Gratz, Marcel
    Blumhagen, Jan Ole
    Jakoby, Bjoern
    Quick, Harald H.
    MEDICAL PHYSICS, 2022, 49 (02) : 865 - 877
  • [42] Hybrid approach for attenuation correction in PET/MR scanners
    Santos Ribeiro, A.
    Mops, E. Rota
    Herzog, H.
    Almeida, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 734 : 166 - 170
  • [43] A comparison of CT- and MR-based attenuation correction in neurological PET
    John C. Dickson
    Celia O’Meara
    Anna Barnes
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1176 - 1189
  • [44] A comparison of CT- and MR-based attenuation correction in neurological PET
    Dickson, John C.
    O'Meara, Celia
    Barnes, Anna
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (06) : 1176 - 1189
  • [45] MR-based truncation and attenuation correction in integrated PET/MR hybrid imaging using HUGE with continuous table motion
    Lindemann, Maike E.
    Oehmigen, Mark
    Blumhagen, Jan O.
    Gratz, Marcel
    Quick, Harald H.
    MEDICAL PHYSICS, 2017, 44 (09) : 4559 - 4572
  • [46] Attenuation Correction of PET/MR Imaging
    Chen, Yasheng
    An, Hongyu
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2017, 25 (02) : 245 - +
  • [47] MR-based respiratory and cardiac motion correction for PET imaging
    Kuestner, Thomas
    Schwartz, Martin
    Martirosian, Petros
    Gatidis, Sergios
    Seith, Ferdinand
    Gilliam, Christopher
    Blu, Thierry
    Fayad, Hadi
    Visvikis, Dimitris
    Schick, F.
    Yang, B.
    Schmidt, H.
    Schwenzer, N. F.
    MEDICAL IMAGE ANALYSIS, 2017, 42 : 129 - 144
  • [48] Deep Learning MR Imaging-based Attenuation Correction for PET/MR Imaging
    Liu, Fang
    Jang, Hyungseok
    Kijowski, Richard
    Bradshaw, Tyler
    McMillan, Alan B.
    RADIOLOGY, 2018, 286 (02) : 676 - 684
  • [49] MR-based correction of respiratory motion in oncological PET imaging using an integrated PET/MR system
    Wuerslin, Christian
    Schmidt, Holger
    Schwenzer, Nina
    Martirosian, Petros
    Claussen, Claus
    Stegger, Lars
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [50] MR-Based PET Motion Correction Procedure for Simultaneous MR-PET Neuroimaging of Human Brain
    Ullisch, Marcus Goerge
    Scheins, Juergen Johann
    Weirich, Christoph
    Kops, Elena Rota
    Celik, Abdullah
    Tellmann, Lutz
    Stoecker, Tony
    Herzog, Hans
    Shah, Nadim Jon
    PLOS ONE, 2012, 7 (11):