Sequential and simultaneous determination of four elements in soil samples using high-resolution continuum source graphite furnace atomic and molecular absorption spectrometry

被引:27
|
作者
Boschetti, W. [1 ]
Orlando, M. [1 ]
Dullius, M. [2 ]
Dessuy, M. B. [1 ,3 ]
Vale, M. G. R. [1 ,3 ]
Welz, B. [3 ,4 ]
de Andrade, J. B. [3 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
[2] Vinicola Geisse, Linha Jansen S-N, BR-95700000 Pinto Bandeira, RS, Brazil
[3] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq INCT Energia & Ambiente, Salvador, BA, Brazil
[4] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
AGRICULTURAL SOILS; TRACE-ELEMENTS; HEAVY-METALS; ACID DIGESTION; SOLID SAMPLES; AQUA REGIA; CADMIUM; CR; FE; TOXICITY;
D O I
10.1039/c6ja00031b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method has been developed for the sequential and simultaneous determination of Cd, Cr, Fe and Al (via the AlH molecule) in soil samples using high-resolution continuum source graphite furnace atomic and molecular absorption spectrometry and direct solid sample analysis. First, Cd (228.802 nm) was determined using 800 degrees C and 1700 degrees C as the pyrolysis and atomization temperatures, respectively. Subsequently, after changing the wavelength, Cr (425.433 nm), Fe (425.076 nm) and Al (425.315 nm) were determined simultaneously from the same sample aliquot using 2600 degrees C as the atomization (Cr and Fe) or vaporization (AlH) temperature. Al determination was carried out using the diatomic molecule AlH without adding a molecule-forming reagent. The interference caused by Al in Cd determination was minimized by using 10 mu L of a 10% v/v H2SO4 solution in all measurements. Aqueous standard solutions were used for calibration and the limits of detection and quantification obtained were 7.3 and 24 pg mg(-1) for Cd, 0.13 and 0.45 ng mg(-1) for Cr, 0.07 and 0.23 mu g mg(-1) for Fe and 0.42 and 1.4 mu g mg(-1) for Al, respectively. The concentration values for Cd, Cr, Fe and Al obtained from the soil certified reference material (CRM) Montana Soil I (NIST SRM 2710a) analysis were in agreement with the reported ones. The precision of the measurements, expressed as the relative standard deviation, was better than 10%. Six soil samples from a vineyard field were investigated and the results are in accordance with the Brazilian legislation.
引用
收藏
页码:1269 / 1277
页数:9
相关论文
共 50 条
  • [1] Sequential and simultaneous determination of chlorine, iron, and silicon in beer samples by high-resolution continuum source graphite furnace molecular and atomic absorption spectrometry
    Pires, Lais N.
    Almeida, Jorge S.
    Dias, Fabio de S.
    Teixeira, Leonardo S. G.
    FOOD ANALYTICAL METHODS, 2020, 13 (09) : 1746 - 1754
  • [2] Sequential and simultaneous determination of chlorine, iron, and silicon in beer samples by high-resolution continuum source graphite furnace molecular and atomic absorption spectrometry
    Laís N. Pires
    Jorge S. Almeida
    Fabio de S. Dias
    Leonardo S. G. Teixeira
    Food Analytical Methods, 2020, 13 : 1746 - 1754
  • [3] Simultaneous determination of rhodium and ruthenium by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Zambrzycka-Szelewa, Elzbieta
    Lulewicz, Marta
    Godlewska-Zylkiewicz, Beata
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 133 : 81 - 87
  • [4] Determination of bromine using high-resolution continuum source molecular absorption spectrometry in a graphite furnace
    Limburg, Tobias
    Einax, Jurgen W.
    MICROCHEMICAL JOURNAL, 2013, 107 : 31 - 36
  • [5] On the possibilities of high-resolution continuum source graphite furnace atomic absorption spectrometry for the simultaneous or sequential monitoring of multiple atomic lines
    Resano, M.
    Rello, L.
    Florez, M.
    Belarra, M. A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (05) : 321 - 328
  • [6] Determination of selenium in soil samples using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Castilho, Ivan N. B.
    Pereira, Ederson R.
    Welz, Bernhard
    Shaltout, Abdallah A.
    Caraseka, Eduardo
    Martensd, Irland B. Gonzaga
    ANALYTICAL METHODS, 2014, 6 (09) : 2870 - 2875
  • [7] Simultaneous and direct determination of iron and nickel in biological solid samples by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Gomez-Nieto, Beatriz
    Jesus Gismera, Ma
    Teresa Sevilla, Ma
    Procopio, Jesus R.
    TALANTA, 2013, 116 : 860 - 865
  • [8] Simultaneous Determination of Chromium and Iron in Powdered Milk Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Santos, Adilson S.
    de Souza, Cheilane T.
    Leao, Danilo J.
    Correia, Felipo O.
    Almeida, Tarcisio S.
    Ferreira, Sergio L. C.
    FOOD ANALYTICAL METHODS, 2020, 13 (01) : 284 - 290
  • [9] Simultaneous Determination of Chromium and Iron in Powdered Milk Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Adilson S. Santos
    Cheilane T. de Souza
    Danilo J. Leao
    Felipo O. Correia
    Tarcísio S. Almeida
    Sergio L. C. Ferreira
    Food Analytical Methods, 2020, 13 : 284 - 290
  • [10] New analytical method for total fluorine determination in soil samples using high-resolution continuum source graphite furnace molecular absorption spectrometry
    Boschetti, Wiliam
    Dessuy, Morgana B.
    Pizzato, Antonio H.
    Vale, Maria Goreti R.
    MICROCHEMICAL JOURNAL, 2017, 130 : 276 - 280