Stent design-related coronary artery remodeling and patterns of neointima formation following self-expanding and balloon-expandable stent implantation

被引:18
|
作者
König, A
Schiele, TM
Rieber, J
Theisen, K
Mudra, H
Klauss, V
机构
[1] Med Klin Innenstadt, Univ Hosp, Dept Cardiol, D-80336 Munich, Germany
[2] Stadt Klinikum Neuperlach, Dept Cardiol, Munich, Germany
关键词
stent type; vessel remodeling; neointima formation; restenosis;
D O I
10.1002/ccd.10249
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The self-expanding Wallstent (WS) and balloon-expandable Palmaz-Schatz stents (PS) display different mechanical and dynamical stent properties. We analyzed the impact of the respective stent design on coronary wall geometry using quantitative coronary angiography (QCA) and intracoronary ultrasound (ICUS) measurements. Serial measurements were performed within the stent and within reference segments of 50 patients (25 WS, 25 PS). Relative changes for each parameter in both stent designs were calculated (Mann-Whitney U-test; 95% CI). The luminal net gain in WS was not significantly higher in WS compared with PS (1.63 +/- 1.11 vs. 1.44 +/- 0.63 mm; P = 0.2554). The respective loss indexes were also similar (0.38 +/- 0.42 vs. 0.36 +/- 0.23; P = 0.8578). The WS segments showed significant postinterventional stent expansion with positive vessel remodeling. The neointima formation was significantly higher in WS segments (4.23 +/- 2.07 vs. 2.22 +/- 2.22 mm(2)). The coronary wall morphology and stent geometry after 6.5 +/- 1.2 months are related to the stent design. In WS segments, the neointima formation was balanced by postinterventional stent expansion, resulting in a comparable relative lumen loss in both stent types. The respective stent design had no impact on the vessel reference segments.
引用
收藏
页码:478 / 486
页数:9
相关论文
共 50 条
  • [41] Differing morphological changes following endovascular AAA repair using balloon-expandable or self-expanding endografts
    Singh-Ranger, R
    Adiseshiah, M
    JOURNAL OF ENDOVASCULAR THERAPY, 2000, 7 (06) : 479 - 485
  • [42] Interventional treatment of hepatic artery stenosis after orthotopic liver transplantation with balloon-expandable coronary stent
    Huang, Q.
    Zhai, R. Y.
    Dai, D. K.
    TRANSPLANTATION PROCEEDINGS, 2007, 39 (10) : 3245 - 3250
  • [43] Impact of Stent Diameter on Stent Patency After Self-expanding Drug-eluting Stent Implantation in Superficial Femoral Artery Lesions
    Miki, Kojiro
    Yanaka, Koji
    Yoshihara, Nagataka
    Kawai, Kenji
    Imanaka, Takahiro
    Akahori, Hirokuni
    Masuyama, Tohru
    Ishihara, Masaharu
    CIRCULATION, 2017, 136
  • [44] Thrombocytopenia after transcatheter aortic valve implantation. A comparison between balloon-expandable and self-expanding valves
    Hernandez-Enriquez, Marco
    Regueiro, Ander
    Romaguera, Rafael
    Andrea, Rut
    Antoni Gomez-Hospital, Joan
    Pujol-Lopez, Margarida
    Luis Ferreiro-Gutierrez, Jose
    Brugaletta, Salvatore
    Roura, Gerard
    Freixa, Xavier
    Gomez-Lara, Josep
    Martin-Yuste, Victoria
    Gracida, Montserrat
    Cequier, Angel
    Sabate, Manel
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (07) : 1344 - 1351
  • [45] IMPACT OF VESSEL SIZE ON STENT PATENCY FOLLOWING SELF-EXPANDING STENTS IMPLANTATION IN SUPERFICIAL FEMORAL ARTERY LESIONS
    Miki, Kojiro
    Yanaka, Koji
    Yoshihara, Nagataka
    Kawai, Kenji
    Imanaka, Takahiro
    Akahori, Hirokuni
    Masuyama, Tohru
    Ishihara, Masaharu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 2057 - 2057
  • [46] Impact of Vessel Size on Stent Patency Following Self-expanding Stents Implantation in Superficial Femoral Artery Lesions
    Miki, Kojiro
    Yanaka, Koji
    Yoshihara, Nagataka
    Kawai, Kenji
    Imanaka, Takahiro
    Akahori, Hirokuni
    Masuyama, Tohru
    Ishihara, Masaharu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (16) : S52 - S52
  • [47] The morphological and histological findings of restenosis after self-expanding biodegradable coronary stent implantation
    Tsuji, T
    Tamai, H
    Igaki, K
    Kyo, E
    Kosuga, K
    Hata, T
    Okada, M
    Nakamura, T
    Fujita, S
    Takeda, S
    Motohara, S
    Uehata, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 25A - 25A
  • [48] Outcomes of the Gore® Excluder® Iliac Branch Endoprosthesis Using Self Expanding or Balloon-Expandable Stent Grafts for the Internal Iliac Artery Component
    Cortolillo, Nicholas S.
    Guerra, Andres
    Murphy, Eric
    Hoel, Andrew W.
    Eskandari, Mark K.
    Tomita, Tadaki M.
    JOURNAL OF ENDOVASCULAR THERAPY, 2024, 31 (06) : 1227 - 1233
  • [49] The impact of gender on outcomes of transcatheter aortic valve implantation between self-expanding valve and balloon-expandable valve
    Tateishi, Kazuya
    Hmoud, Hosam
    De Gregorio, Isabella
    Hastings, Ramin
    De Gregorio, Joseph
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2024, 63 : 38 - 42
  • [50] BALLOON-EXPANDABLE STENT IMPLANTATION IN PATIENTS WITH RENOVASCULAR HYPERTENSION DUE TO ATHEROSCLEROTIC OSTIAL RENAL-ARTERY STENOSIS
    VANDERVEN, PJG
    BEUTLER, JJ
    GEYSKES, GG
    WOITTIEZ, AJ
    BEEK, FJA
    MALI, WPTM
    KOOMANS, HA
    KIDNEY INTERNATIONAL, 1995, 48 (04) : 1368 - 1368