Stent design-related coronary artery remodeling and patterns of neointima formation following self-expanding and balloon-expandable stent implantation

被引:18
|
作者
König, A
Schiele, TM
Rieber, J
Theisen, K
Mudra, H
Klauss, V
机构
[1] Med Klin Innenstadt, Univ Hosp, Dept Cardiol, D-80336 Munich, Germany
[2] Stadt Klinikum Neuperlach, Dept Cardiol, Munich, Germany
关键词
stent type; vessel remodeling; neointima formation; restenosis;
D O I
10.1002/ccd.10249
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The self-expanding Wallstent (WS) and balloon-expandable Palmaz-Schatz stents (PS) display different mechanical and dynamical stent properties. We analyzed the impact of the respective stent design on coronary wall geometry using quantitative coronary angiography (QCA) and intracoronary ultrasound (ICUS) measurements. Serial measurements were performed within the stent and within reference segments of 50 patients (25 WS, 25 PS). Relative changes for each parameter in both stent designs were calculated (Mann-Whitney U-test; 95% CI). The luminal net gain in WS was not significantly higher in WS compared with PS (1.63 +/- 1.11 vs. 1.44 +/- 0.63 mm; P = 0.2554). The respective loss indexes were also similar (0.38 +/- 0.42 vs. 0.36 +/- 0.23; P = 0.8578). The WS segments showed significant postinterventional stent expansion with positive vessel remodeling. The neointima formation was significantly higher in WS segments (4.23 +/- 2.07 vs. 2.22 +/- 2.22 mm(2)). The coronary wall morphology and stent geometry after 6.5 +/- 1.2 months are related to the stent design. In WS segments, the neointima formation was balanced by postinterventional stent expansion, resulting in a comparable relative lumen loss in both stent types. The respective stent design had no impact on the vessel reference segments.
引用
收藏
页码:478 / 486
页数:9
相关论文
共 50 条
  • [21] PERSISTENT ILIAC ENDARTERITIS WITH PSEUDOANEURYSM FORMATION FOLLOWING BALLOON-EXPANDABLE STENT PLACEMENT
    LIU, P
    DRAVID, V
    FREIMAN, D
    ZEGEL, H
    WEINBERG, D
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 18 (01) : 39 - 42
  • [22] Impact of Stent Diameter on Stent Patency After Self-expanding Nitinol Stent Implantation in the Superficial Femoral Artery
    Miki, Kojiro
    Akahori, Hirokuni
    Masuyama, Tohru
    Ishihara, Masaharu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (16) : S72 - S72
  • [23] Self- and balloon-expandable stent implantation for severe native coarctation of aorta in adults
    Tyagi, S
    Singh, S
    Mukhipadhyay, S
    Kaul, UA
    AMERICAN HEART JOURNAL, 2003, 146 (05) : 920 - 928
  • [24] Very Late Stent Thrombosis Caused by Rupture of Lipid-Laden Neointima in a Self-Expanding Coronary Stent
    Koga, Seiji
    Ikeda, Satoshi
    Yoshida, Takeo
    Nakata, Tomoo
    Takeno, Masayoshi
    Koide, Yuji
    Maemura, Koji
    INTERNATIONAL HEART JOURNAL, 2012, 53 (03) : 202 - 204
  • [25] Performance of Viabahn Balloon-Expandable Stent Compared With Self-expanding Covered Stents for Fenestrated-Branched Endovascular Aortic Repair
    Motta, Fernando
    Parodi, Frederico E.
    Crowner, Jason R.
    Pas-Carella, Luigi
    McGinigle, Katharine L.
    Marston, William A.
    Kibbe, Melina R.
    Farber, Mark A.
    JOURNAL OF VASCULAR SURGERY, 2020, 71 (01) : E28 - E29
  • [26] Overdilation of a 6-mm Self-Expanding Stent with a 10-mm Balloon-Expandable Stent Graft Preserves Failing Meso-Rex Bypass
    Koethe, Yilun
    Lokken, R. Peter
    Lehrman, Evan D.
    Kerlan, Robert K.
    Roberts, John P.
    Rhee, Sue J.
    Kohi, Maureen P.
    Kolli, K. Pallav
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 31 (03) : 521 - 523
  • [27] CT Simulation of Redo TAVR With Deep Implantation of Balloon-Expandable Within Self-Expanding Valve
    Medranda, Giorgio A.
    Jimenez, Cesar E. Soria
    Case, Brian C.
    Forrestal, Brian
    Ali, Syed W.
    Shea, Corey
    Zhang, Cheng
    Asch, Federico
    Weissman, Gaby
    Shults, Christian C.
    Garcia-Garcia, Hector M.
    Ben-Dor, Itsik
    Satler, Lowell F.
    Waksman, Ron
    Rogers, Toby
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (04) : S83 - S83
  • [28] Balloon-expandable covered stent implantation for treatment of a traumatic pulmonary artery pseudoaneurysm in a pediatric patient
    Palmieri, Vincent J.
    Heal, Elisabeth
    Chowdhury, Shahryar M.
    Bandisode, Varsha M.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (02): : E73 - E76
  • [29] Self-expanding stent for spontaneous coronary artery dissection: a rational choice
    Mele, Marco
    Langialonga, Tommaso
    Maggi, Alessandro
    Villella, Massimo
    Villella, Alessandro
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2016, 17 : E254 - E256
  • [30] IMPACT OF FINAL STENT DIMENSIONS ON ANGIOGRAPHIC RESTENOSIS FOLLOWING SELF-EXPANDING NITINOL STENT IMPLANTATION IN THE SUPERFICIAL FEMORAL ARTERY LESION
    Miki, Kojiro
    Fujii, Kenichi
    Kimura, Takumi
    Okada, Kozo
    Masuyama, Tohru
    Ishihara, Masaharu
    Fitzgerald, Peter
    Honda, Yasuhiro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 313 - 313